Advertisement

Quick Links

Sanosil Q-Jet Compact
Operation and Maintenance Manual
Sanosil Q-Jet Compact
Series 2
Des M 56en – Q-Jet Compact 2+
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Q-Jet Compact 2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Sanosil Q-Jet Compact 2 Series

  • Page 1 Sanosil Q-Jet Compact Operation and Maintenance Manual Sanosil Q-Jet Compact Series 2 Des M 56en – Q-Jet Compact 2+...
  • Page 2: Table Of Contents

    Authorized Persons ....................4 Disclaimer ......................5 Room Disinfecting with the Sanosil Q-Jet Fogger ..........5 Different ways to use the Sanosil Q-jet Compact ..........5 Important safety Directions (Read carefully before use) ........6 Product Description ..................7 Technical Data ......................7 Parts and Functions ....................
  • Page 3: Introduction

    Sanosil Q-Jet Compact Introduction 1.1 Used Symbols Inside this manual or on the device there are Symbols having the following meaning: High risk! Disregard can lead to death or heavy injuries! Medium risk! Disregard can lead to death or heavy injuries!
  • Page 4: Intended Usage

    Do always and only use suitable Sanosil disinfectants with a maximal hydrogen Peroxide content of 7.5%. The usage of any other disinfectant or accessories which are not specifically approved by Sanosil Ltd. is against the rules herein and can lead to heavy injuries as well as to damaging the device. The device is not meant for use as a stand-alone disinfection process but rather as an addition to regular cleaning and disinfection.
  • Page 5: Disclaimer

    How to use the Sanosil Q-Jet Compact: Fogging of Sanosil Disinfectants (only use Sanosil ready for use products containing up to 7.5% hydrogen Peroxide) can be used for disinfecting hard, nonporous surfaces in rooms as an adjunct following regular cleaning and disinfecting of room surfaces.
  • Page 6: Important Safety Directions (Read Carefully Before Use)

    To ensure effectiveness and safety, use only with Sanosil disinfectant. Using any other manufacturer’s disinfecting or cleaning product will result in serious injury, exposure and environmental damage. Sanosil Ltd. is not responsible for any injury or damage caused by using this device outside of the specific parameters detailed in this manual.
  • Page 7: Product Description

    Sanosil Q-Jet Compact Product Description 3.1 Technical Data Power requirements: 220 - 240 V, 50Hz (fuse 6.3 A) Amperage: max. 5 A Operating temperature / 5°C to 35°C / max. 45% rH (before fogging) at higher humidity, the humidity must be lowered humidity: before start-up or a lower dosage of the active substance must be selected.
  • Page 8: Trolley (Optional)

    Sanosil Q-Jet Compact 3.7 Trolley (optional) • place the device on top of trolley • secure the device with the screw on the trolley CAUTION Risk of crushing! Hands and fingers can be crushed between device and trolley! Do always wear device on handle bars while setting the device on the trolley!
  • Page 9: Operating Instructions

    Sanosil Q-Jet Compact Operating Instructions 4.1 Warning WARNING Risk of Injuries! This device nebulizes chemical substances! Do not inhale these substances, always wear safety equipment when filling/emptying tank and pay attention to optical and acoustic warning signals. Read carefully all indications stated on the safety data sheet of the disinfection liquid and fully comply...
  • Page 10: Establish Nebulization Time

    Please see table below for your convenience. Higher concentrations of 16 or 24ml/m may be required for some conditions. Please ask your Sanosil sales representatives for detailed info. • Please read and follow important safety directions on page 6 before use! 4.2.4...
  • Page 11: Set Up Devices

    Sanosil Q-Jet Compact 4.3 Set up Device 4.3.1 Calibration Initial use and frequently we recommend calibrating the device to make sure the tank filling level to be correct on the display. Find the calibration procedure in chapter 5, page 15 of this document.
  • Page 12: Switch On The Device

    Sanosil Q-Jet Compact 4.3.4 Switch on the device • Tip ON/OFF (3) to switch on the device 4.3.5 Setting up the device Please read and follow important safety directions on page 6 Display Important safety Directions (Read carefully before use) before use! •...
  • Page 13: Procedure Before Re-Entering The Room

    Sanosil Q-Jet Compact Procedure before re-entering the room 4.4.1 Right procedure before re-entering the room • Check with a hydrogen peroxide level sensor that the H -Level is below your local maximum permissible value or if not specified at least below 1 ppm.
  • Page 14: Emptying The Tank

    Sanosil Q-Jet Compact 4.5 Emptying the Tank CAUTION! Risk of injuries! Do always wear gloves and safety googles when emptying the tank! • Before emptying the tank always turn OFF the device and disconnect the power supply plug! • Unscrew rear panel and remove it •...
  • Page 15: Calibration, Maintenance And Troubleshooting

    Sanosil Q-Jet Compact Calibration, maintenance and troubleshooting WARNING Risk of injury! Do always switch off the device and disconnect the power supply cord/plug and empty the tank of the device fully before starting any cleaning or maintenance works! Maintenance works can only be carried out through well-trained personnel or professional electricians.
  • Page 16: Maintenance

    Sanosil Q-Jet Compact 5.2 Maintenance 5.2.1 Warning WARNING Risk of injury! Do always switch off the device and disconnect the power supply cord before starting any cleaning or maintenance works. Maintenance works can only be carried out through well-trained personnel.
  • Page 17: Troubleshooting

    Sanosil Q-Jet Compact Troubleshooting When asking for support with your agent: make sure in any case to fill in accurately manufactures Complaint Form before any contacting! Trouble Possible cause Solution • Check power supply • Ensure power supply to device Device does not work / does not •...
  • Page 18: Warranty

    (e.g, air filter, etc.). Sanosil Ltd / CleanService Group Ltd. (manufacturer) will have the choice to repair the device, to replace it or to reimburse the actual paid amount. A warranty service does not extend the length of the warranty. Sanosil Ltd / CleanService Group Ltd.
  • Page 19: Ce-Declaration Of Conformity

    Sanosil Q-Jet Compact CE-Declaration of Conformity...
  • Page 20 Sanosil Q-Jet Compact Sanosil Ltd Eichtalstrasse 49 CH-8634 Hombrechtikon Switzerland e-mail: info@sanosil.com www.sanosil.com Tel.: +41 55 254 00 54 Fax: +41 55 254 00 59...

This manual is also suitable for:

Q-jet compact 2+

Table of Contents