Authorized Persons ....................5 Disclaimer ......................6 Room Disinfecting with the Sansoil Q-Jet Fogger ..........6 Different ways to use the Sanosil Q-jet Compact ..........6 Important safety Directions (Read carefully before use) ........7 Product Description ..................8 Technical Data ......................8 Parts and Functions ....................
Sanosil Q-Jet Compact Introduction 1.1 Used Symbols Inside this manual or on the device there are Symbols having the following meaning: High risk! Disregard can lead to death or heavy injuries! Medium risk! Disregard can lead to death or heavy injuries!
Do always and only use suitable Sanosil disinfectants with a maximal hydrogen Peroxide content of 7.5%. The usage of any other disinfectant or accessories which are not specifically approved by Sanosil Ltd. is against the rules herein and can lead to heavy injuries as well as to damaging the device. The device is not meant for use as a stand-alone disinfection process but rather as an addition to regular cleaning and disinfection.
How to use the Sanosil Q-Jet Compact: Fogging of Sanosil Disinfectants (only use Sanosil ready for use products containing up to 7.5% hydrogen Peroxide) can be used for disinfecting hard, nonporous surfaces in rooms as an adjunct following regular cleaning and disinfecting of room surfaces.
To ensure effectiveness and safety, use only with Sanosil disinfectant. Using any other manufacturer’s disinfecting or cleaning product will result in serious injury, exposure and environmental damage. Sanosil Ltd. is not responsible for any injury or damage caused by using this device outside of the specific parameters detailed in this manual.
• Air-filter set 1 Power cord 1 Operation and User Manual with attachments 3.6 Recommended Equipment • Respirator mask filter ABE1 3.4 Q-jet Compact Accessories • Handheld H Sensor measurement 0-20ppm (for • Trolley example Dräger X-am 5100) • Case for transportation...
Sanosil Q-Jet Compact 3.7 Trolley (optional) • place the device on top of trolley • secure the device with the screw on the trolley WARNING Risk of crushing! Hands and fingers can be crushed between device and trolley! Do always wear device on handle bars while setting the device on the trolley!
Sanosil Q-Jet Compact Getting Started and Operating Instructions 4.1 Position • Place device on a stable, flat, dust-free, not slippery, horizontal surface which can appropriately support its weight. • Point nozzle towards center of the room. • Do not point nozzle towards smoke detectors and check with facility management to take appropriate measures that the former will not be activated during nebulization process 4.2 Power Connection...
Please see table below for your convenience. Higher concentrations of 16 or 24ml/m may be required for some microorganisms or room conditions. Please ask your Sanosil sales representatives for detailed info. • Please read and follow important safety directions on page 6 before use!
Sanosil Q-Jet Compact 4.5.2 Setting up the Device Please read and follow important safety directions on page 6 before use! • Switch on the device T:01 (Display flashes) • Enter time in minutes through number buttons pqrs wxyz (If mistake or change: renewed time input by pressing arrow button “left“)
Sanosil Q-Jet Compact 4.5.3 Procedure before re-entering the room • Check with a hydrogen peroxide level sensor that the H -Level is below 1ppm • Open windows and doors for min. 15 minutes, unseal HVAC vents and restart HVAC system to allow increased airflow circulation in the room.
Sanosil Q-Jet Compact Maintenance WARNING Risk of injury! Do always switch off the device and disconnect the power supply cord/plug before starting any cleaning or maintenance works! Maintenance works can only be carried out through well-trained personnel or professional electricians. Observe all safety indications stated above, in chapter 2.
Sanosil Q-Jet Compact Troubleshooting To determine and search for anomalies it is essential to have this Operation and User Manual at hand. • Do not tip the device on its side over 60°at any time unless completely empty and dry.
Sanosil Q-Jet Compact Warranty Sanosil Ltd and CleanService Group Ltd. (manufacturer of the Sanosil Q-Jet) warrants the Sanosil Q-Jet to be free of any defects in material and workmanship and to perform in accordance with the manufacturer’s specifications. Provided the device will be used in accordance with Sanosil Ltd/CleanService Group’s recommendations, the warranty will last for 2...