Connecting the indoor/outdoor Electric Cable

Removing the wiring cover

Remove terminal cover at right bottom corner of indoor unit, then
take off wiring cover by removing its screws.
When connecting the cable after installing the indoor unit
1. Insert from outside the room cable into left side of the wall hole, in which
the pipe has already existed.
2. Pull out the cable on the front side, and connect the cable making a loop.
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and tightened.
After the cable connection, never fail to fasten the connected cable with the wiring cover.
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring
is not correct, proper operation can not be carried out and will cause defect.
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the
distance between its two contacts should be not less than 3mm.
Indoor unit
HSU-07HEA03
HSU-09HEA03
HSU-12HEB03
Indoor unit
HSU-22HEA03
HSU-24HEA03
Indoor unit
Outdoor unit
POWER
Outdoor unit
5
Indoor unit
HSU-18HEA03
HSU-12HEA03
connecting wiring:
-mod 07-12:
-mod
18:
-mod 22-24:
Power cable:
-mod 07-12:
-mod
18:
3G2.5mm
-mod 22-24:
3G2.5mm
Outdoor unit
2X0.75mm +3X1.0mm
2X0.75mm +3X2.5mm
6G0.75mm
3G1.0mm

Advertisement

Table of Contents
loading

Table of Contents