Year: 2022
ECLERIS USA
11801 NW 100th Rd
Suite 17
Medley, FL 33178, U.S.A.
Phone: +1 786 483 7490
MICROSCOPE
Language: English
CMC Medical Devices & Drugs S.L.
C/ Horacio Lengo Nº18, CP29006,
Málaga, Spain
Ph. +34951214054
Email: info@cmcmedicaldevices.com

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MICROSTAR OM-200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Ecleris MICROSTAR OM-200 Series

  • Page 1 All the rights to this manual are reserved, especially reproduction, publication and translation rights. No portion of this manual may be reproduced by no means (photocopy, microfilm or other methods) without previous written authorization from ECLERIS. Neither can it be reproduced, multiplied or published through any electronic data processing form.
  • Page 2: Table Of Contents

    USER MANUAL / MANUAL DE USUARIO– MICROSTAR TABLE OF CONTENT SYMBOLS ..........................4 SAFETY INFORMATION ......................5 WARNINGS .......................... 5 DESCRIPTION......................... 6 INTENDED USE ........................6 INTENDED USER ........................ 6 DESCRIPTION AND COMPONENTS .................. 6 3.3.1 FLOOR STAND MICROSCOPE (OM-200F) ..............7 3.3.2 WALL-STAND MICROSCOPE (OM-200W) ..............
  • Page 3 USER MANUAL / MANUAL DE USUARIO– MICROSTAR OPTICAL HEAD TILT ......................30 MICROSCOPE TRANSPORT .................... 31 MOUNTING THE MONITOR HOLDER................31 MAINTENANCE ........................34 CLEANING ......................... 34 7.1.1 CLEANING THE EXTERNAL SURFACES ..............34 7.1.2 DISINFECTION ......................34 7.1.3 CLEANING OF OBJECTIVE LENS AND EYEPIECES ..........34 ELECTRICAL CONNECTIONS ..................
  • Page 4: Symbols

    USER MANUAL / MANUAL DE USUARIO– MICROSTAR 1. SYMBOLS EU Authorized Warning Representative Caution CE Mark Read the related documentation This side up Alternate current Fuse Protective earth (Ground) Video output Equipotential bonding Freeze image function Manufacturer identification Video camera (Name, Address) Serial number White balance function...
  • Page 5: Safety Information

    2.1 WARNINGS It is important to read this manual carefully before using the Microstar Microscope. ECLERIS will not be held responsible for damage that can occur to the device due to not following the instructions or not observing the following criteria: ...
  • Page 6: Description

    USER MANUAL / MANUAL DE USUARIO– MICROSTAR  Do not open the device. Maintenance and repairs must be done by ECLERIS or an authorized company by the fabricant. ECLERIS will not be responsible for the consequences of repairs or maintenance carried out by unauthorized personnel.
  • Page 7: Floor Stand Microscope (Om-200F)

    USER MANUAL / MANUAL DE USUARIO– MICROSTAR Longitud de brazo Código Configuración pantográfico/ 23.03” (585mm) OM-200F Floor-stand 32,09” (815mm) 23.03” (585mm) OM-200C Ceiling-stand 32,09” (815mm) 23.03” (585mm) OM-200W Wall-stand 32,09” (815mm) 3.3.1 FLOOR STAND MICROSCOPE (OM-200F) Components: Page 7 of 80 INMANUUML019 USER MANUAL/M.
  • Page 8: Wall-Stand Microscope (Om-200W)

    USER MANUAL / MANUAL DE USUARIO– MICROSTAR Optical Head 8. Switch on/off 2. HD Splitter 9. Forearm 3. Binocular 10. Progressive brake 4. Tension knob 11. Progressive brake 5. Progressive brake 12. Column 6. Lock brake 13. Microscope Base 7. Parallelogram arm compensator 3.3.2 WALL-STAND MICROSCOPE (OM-200W) Components:...
  • Page 9: Ceiling-Mount Microscope (Om-200C)

    USER MANUAL / MANUAL DE USUARIO– MICROSTAR 1. Optical Head 8. ON/OFF interruptor 2. HD Splitter 9. Progressive break 3. Binocular 10. Forearm 4. Tension knob 11. Progressive break 5. Progressive break 12. Column 6. Lock brake 13. Wall support 7.
  • Page 10: Optical Head

    USER MANUAL / MANUAL DE USUARIO– MICROSTAR 4. Tension knob 12. Ceiling-column adapter 5. Progressive break 13. Telescopic column 6. Lock brake 14. Cover 7. Parallelogram arm compensator 15. Ceiling Support 8. Ceiling support 9. ON/OFF interruptor 3.3.4 OPTICAL HEAD Magnification selector 5.
  • Page 11: Installation And Operation

    4. INSTALLATION AND OPERATION FLOOR-STAND (OM-200F) 4.1.1 BASE INSTALLATION To assemble the microscope base, 4 wheels and 4 counterweights must be fitted. The wheels are assembled by screwing the bolt into the ends of the base as indicated in the following figure.
  • Page 12: Column Installation

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR Once the weights have been mounted, the plastic base cover must be placed on the base, as indicated in the following figure: 4.1.2 COLUMN INSTALLATION Once the wheels and the base cover are placed, the column must be mounted on the base. Install the column in the central axis of the base, as is indicated in the following figure: Tighten the set screw with an Allen wrench.
  • Page 13: Forearm-Column Installation

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR The column has to be mounted in the right position, as indicated in the following figure: Column Top Column Bottom 4.1.3 FOREARM-COLUMN INSTALLATION Place the forearm on top of the column, then tighten the screw in order to solidly attach the forearm to the column.
  • Page 14: Wall-Stand (Om-200W)

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR WALL-STAND (OM-200W) Before installing the Wall-support, adjust the column to the desired column length, firmly on the desired level. The Wall-stand support should be settled on high resistance walls only. It should not be settled on a hollow brick Wall or on walls of 15 cm or thinner thickness, gypsum boards, wooden partition, or any other low resistance material.
  • Page 15 Check that the leveling is correct before drilling the wall. 6) The wall-mount should remain firmly. ECLERIS is not responsible for any physical or equipment damage that may occur due to the incorrect fixation of the wall-mount. 7) Loosen the Allen screws from the forearm-attach-piece of the wall-mount using the supplied 3/16’’...
  • Page 16: Ceiling-Stand (Om-200C)

    10) Continue by following the steps on 4.4. section for head, binocular, eye pieces installation. CEILING-STAND (OM-200C) ECLERIS does not provide the materials nor the instructions for the ceiling support install and are not responsible for its incorrect installation or physical/material damage caused by improper fixing.
  • Page 17 MANUAL DE USUARIO / USER MANUAL – MICROSTAR Use metal expansion plugs for concrete of an admissible minimum tensile load of at least 8kN each. 2) Unscrew the 3 internal telescopic column screws using a 3/16’’ Allen key. 3) Fix the column firmly to the ceiling-support base. 4) Slide the plastic cover through the column, from the extreme to a desired height.
  • Page 18 MANUAL DE USUARIO / USER MANUAL – MICROSTAR 5) Now install the telescopic column through its cover. Previously make sure to dis-adjust the 3/16’’ Allen screws. 6) Place the security screw and washer on the end part of the column. Adjust using a fixing key of 14 mm.
  • Page 19 MANUAL DE USUARIO / USER MANUAL – MICROSTAR 8) If desired to install a column extension piece, it should be done now. Dis-adjust the Allen screws on the end of the column, place the extension in and fix it using the same Allen screws.
  • Page 20: Optical Head-Arm Installation

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR 11) Continue by following the steps on 4.4. section for head, binocular and eye pieces installation. OPTICAL HEAD-ARM INSTALLATION The optical head is mounted to the arm through a joint elbow of 60º, as shown in the picture below.
  • Page 21: Binocular-Splitter Installation

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR Place the thick washer (A) on the 60º joint elbow. Dis-adjust the progressive brake (G) completely setting it to the minimum level. Then install the elbow on the microscope arm. Continue placing the fine washer (B) on the arm, as the previous picture.
  • Page 22 MANUAL DE USUARIO / USER MANUAL – MICROSTAR In case of installing the binocular, release the optical head adjustment screw, so that the binocular is inserted centrally in the upper part of the optical head. After the joint is centered and the flat portion is against the head, press the adjustment screw so that the binocular remains firmly attached to the head.
  • Page 23: Video Cables Installation

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR VIDEO CABLES INSTALLATION The splitter and the optical head with integrated light, have specific power and video connectors for regular operation. Once the splitter is mounted to the optical head, proceed to connect the video and power cables.
  • Page 24 MANUAL DE USUARIO / USER MANUAL – MICROSTAR Página 24 de 80 INMANUUML019 USER MANUAL/M. USO OM-200 V.2022.05 ENG/ESP US...
  • Page 25: Operation - Functions

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR 5. OPERATION - FUNCTIONS MICROSCOPE OPERATION This section describes the equipment functioning procedure. The device shall only be operated by personnel trained in the use of this type of microscopes. 1) Connect the power supply cable to the microscope and then to the mains. 2) Press the power switch on the forearm to turn the unit on (the green indicator light will turn on).
  • Page 26: Light Source

    LIGHT SOURCE The Ecleris Microstar OM-200 Microscope has a light module integrated to the microscope’s optical head. From this module you can turn the light on or off, vary its intensity, select different diaphragm levels to reduce the illuminated field and select different light filters.
  • Page 27: Interpupillary Distance Adjustment

    55 and 75 mm. 5.5 DIOPTRIC CORRECTION ADJUSTMENT The Ecleris Microstar OM-200 Microscope has independent dioptric correction for both eyepieces. The adjustment is made by turning the eyepieces towards the + sign or the – sign. 5.6 MAGNIFICATION VARIATION The magnification selector has six positions: 4/6/10/16/25x.
  • Page 28: Movement And Shipping

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR 6. MOVEMENT AND SHIPPING For the floor-stand setting microscope (OM-200F) it is mounted on 4-wheel-base with independent brakes for each wheel. These allow an easy transport of the device to locate the best required working position.
  • Page 29: Rotational Movement Of The Optical Head

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR The lock brake of the arm must be loosen to balance the Pantographic arm weight. Place the arm at horizontal position (halfway between minimum and maximum height) and adjust or loosen the compensation system, with an Allen key, in order to balance the accessories’...
  • Page 30: Optical Head Rotation Axis

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR 6.4 OPTICAL HEAD ROTATION AXIS For a better alignment of the optical axis in relation with the target, the head can be rotated on the fork. The rotational range is 0-360 degrees. The movement can be adjusted or completely locked using the control knob.
  • Page 31: Microscope Transport

    6.6 MICROSCOPE TRANSPORT The Ecleris Microstar OM-200 Microscope has been designed to be moved over short distances within a doctor’s office or room. If it necessary to move the microscope over larger distances, special attention should be paid to the following cautions: ...
  • Page 32 MANUAL DE USUARIO / USER MANUAL – MICROSTAR 3. Mount the monitor holder on the back of the monitor and place the 4 Allen screws. 4. Place the column support to the end of the monitor holder. 5. Fit the Allen screw to secure the joint. Página 32 de 80 INMANUUML019 USER MANUAL/M.
  • Page 33 MANUAL DE USUARIO / USER MANUAL – MICROSTAR Página 33 de 80 INMANUUML019 USER MANUAL/M. USO OM-200 V.2022.05 ENG/ESP US...
  • Page 34: Maintenance

    (See Technical specifications). Every moving pieces or mechanisms are maintenance free, these does not require periodic lubrication. To perform any revision and maintenance contact your local distributor or the nearest ECLERIS office 7.1 CLEANING Before cleaning the microscope, disconnect the power supply cable from the mains.
  • Page 35: Fuse Change

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR  Faulty, broken or cut cables.  Faulty connection between the cable and the plug.  Oxide corrosion in connections pins. 7.3 FUSE CHANGE Disconnect the power cord from the electrical network. 1) Disconnect the power cord from the electrical network 2) Remove the forearm access cover to reach the fuse housing.
  • Page 36: Technical Specifications

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR 5) Place the fuse lid back, pushing it until it “clicks”. 6) Connect the power cord to the electrical network. 8. TECHNICAL SPECIFICATIONS MICROSTAR OM-200 MICROSCOPE OPTICAL SYSTEM Composed of apochromatic lenses with a fungus-resistant coating BINOCULAR TUBES 45º...
  • Page 37 MANUAL DE USUARIO / USER MANUAL – MICROSTAR DIMMER Electronic PANTOGRAPH ARM TYPE WBS-Weight Balance System ROTATION MOVEMENTS Proximal and distal rolling bearings system CONEXIONES DC Plug 12Vcc (4 Acc) (connection to HD Splitter and Head) HDMI (connection to HD Splitter) USB 5V-2,4ª...
  • Page 38 MANUAL DE USUARIO / USER MANUAL – MICROSTAR STORAGE AND TRANSPORTATION CONDITIONS -22 – 122 ºF TEMPERATURE 10 – 95 % relative humidity HUMIDITY 500 – 1060 hPa ATMOSPHERIC PRESSURE Página 38 de 80 INMANUUML019 USER MANUAL/M. USO OM-200 V.2022.05 ENG/ESP US...
  • Page 39: Troubleshooting

    If the problem cannot be solved, please contact your local distributor or the closet ECLERIS office and request technical service. Página 39 de 80 INMANUUML019 USER MANUAL/M. USO OM-200 V.2022.05 ENG/ESP US...
  • Page 40: Technical Service

    Problem´s description 4) Send the Microscope for repair or replacement. The ECLERIS Microstar OM-200 Microscope shall be sent in its original Packaging so that it is not damaged during transportation. ECLERIS shall not be liable for damages that may occur during transportation, caused by deficient packaging.
  • Page 41 La información contenida en este manual puede ser modificada o ampliada sin notificación previa, sin que ello represente responsabilidad alguna para ECLERIS. ECLERIS USA CMC Medical Devices & Drugs S.L.
  • Page 42 MANUAL DE USUARIO / USER MANUAL – MICROSTAR TABLA DE CONTENIDO SIMBOLOGIA ........................44 INFORMACION DE SEGURIDAD ..................45 ADVERTENCIAS ........................ 45 DESCRIPCION ........................46 USO PREVISTO ......................... 46 USUARIO PREVISTO ......................46 DESCRIPCION Y COMPONENTES ................... 46 3.3.1 MICROSCOPIO CON ESTATIVO DE PIE (OM-200F) ..........47 3.3.2 MICROSCOPIO CON ESTATIVO DE PARED (OM-200W) .........
  • Page 43 MANUAL DE USUARIO / USER MANUAL – MICROSTAR MOVIMIENTO DE GIRO DEL CABEZAL ................70 MOVIMIENTO DE BALANCEO DEL CABEZAL (MOVIMIENTO BASCULANTE) ....71 TRANSPORTE DEL MICROSCOPIO ................. 71 MONTAJE DEL SOPORTE MONITOR ................72 MANTENIMIENTO ......................... 74 LIMPIEZA ........................... 74 7.1.1 LIMPIEZA DE SUPERFICIES EXTERIORES ..............
  • Page 44: Simbologia

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR 1. SIMBOLOGIA Representante Advertencia Autorizado en la Comunidad Europea Precaución Marcado CE Es obligatorio consultar los Arriba documentos acompañantes Tensión alterna Fusible Puesta a Tierra de Protección Salida de Video Tierra de Equipotencialidad Congelar Imagen Identificación del fabricante Cámara de Video...
  • Page 45: Informacion De Seguridad

    Lea cuidadosamente todo el manual antes de utilizar el dispositivo. Ante cualquier duda sobre el contenido de este manual, la utilización o seguridad del dispositivo, solicitamos comunicarse con su distribuidor local o con la oficina de ECLERIS más cercana. 2.1 ADVERTENCIAS Es importante leer cuidadosamente este manual antes de utilizar el Microscopio Microstar.
  • Page 46: Descripcion

     No abra el equipo. El mantenimiento y las reparaciones deben ser realizados por ECLERIS o una empresa autorizada por ésta. ECLERIS no se responsabiliza por las consecuencias de reparaciones o mantenimientos efectuados por personas no autorizadas.
  • Page 47: Microscopio Con Estativo De Pie (Om-200F)

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR Los componentes accesorios del microscopio OM-200 son los siguientes:  Soporte para monitor  Sistema de video  Cable especial que contiene 1 ficha HDMI macho para conectar al sistema de video, y 2 fichas de alimentación DC-PLUG para alimentar el sistema de video y la luz integrada.
  • Page 48: Microscopio Con Estativo De Pared (Om-200W)

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR 1. Cabezal óptico 8. Interruptor de Encendido 2. Divisor de imagen HD 9. Antebrazo 3. Binocular 10. Freno Progresivo 4. Regulación de tensión 11. Freno Progresivo 5. Freno Progresivo 12. Columna 6. Freno Bloqueo 13.
  • Page 49: Microscopio Con Estativo De Techo (Om-200C)

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR 1. Cabezal de microscopio 8. Interruptor de Encendido 2. Divisor de imagen HD 9. Freno Progresivo 3. Binocular 10. Antebrazo 4. Regulación de tensión 11. Freno Progresivo 5. Freno Progresivo 12. Columna 6.
  • Page 50: Cabezal

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR 3. Binocular 11. Freno Progresivo 4. Regulación de tensión 12. Adaptador columna - techo 5. Freno Progresivo 13. Columna Telescópica 6. Freno Bloqueo 14. Cobertor 7. Compensador de Brazo pantográfico 15. Soporte Techo 8.
  • Page 51: Instalacion Y Puesta En Marcha

    MANUAL DE USUARIO / USER MANUAL – MICROSTAR 4. INSTALACION Y PUESTA EN MARCHA 4.1 ESTATIVO DE PISO (OM-200F) 4.1.1 INSTALACION DE LA BASE Para ensamblar la base del microscopio se deben colocar 4 ruedas y 4 contrapesos. Las ruedas se montan enroscando el perno de la misma en los extremos de la base como indica la figura siguiente.
  • Page 52: Instalacion De La Columna

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR Una vez colocados los pesos, se debe montar el cobertor plástico sobre la base de la columna como indica la siguiente figura: 4.1.2 INSTALACION DE LA COLUMNA La columna se debe instalar sobre la base, una vez que están las ruedas y el cobertor colocados. Para instalar la columna se debe colocar la misma sobre el eje central de la base como indica la siguiente figura: Ajustar el tornillo de fijación con una llave Allen.
  • Page 53: Instalacion Del Antebrazo A La Columna

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR La columna tiene que ser montada en la posición correcta, como se indica en la siguiente figura: Columna Parte Superior Columna Parte Inferior 4.1.3 INSTALACION DEL ANTEBRAZO A LA COLUMNA Colocar el antebrazo en la parte superior de la columna, y luego fijar el tornillo para que el antebrazo quede fijado sólidamente a la columna.
  • Page 54: Estativo De Pared (Om-200W)

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR 4.2 ESTATIVO DE PARED (OM-200W) Antes de proceder a la instalación del estativo de pared, debe determinar la altura adecuada para su fijación y la correcta nivelación. El estativo de pared deberá colocarse únicamente en paredes de alta resistencia. No se lo debe instalar en paredes de ladrillo hueco o de espesores menores a 15 cm, placas de yeso, tabiques de madera o cualquier otro material de baja resistencia.
  • Page 55 Antes de perforar la pared verifique que la nivelación sea correcta 6) El estativo de pared debe permanecer firme. ECLERIS no es responsable por los daños físicos y/o materiales que pudieran ocurrir debido a la incorrecta fijación del estativo a la pared.
  • Page 56: Estativo De Techo (Om-200C)

    10) Siga con los pasos en la sección 4.4 para la instalación del cabezal, binocular y oculares. 4.3 ESTATIVO DE TECHO (OM-200C) ECLERIS no provee los materiales para la fijación del estativo de techo y no es responsable por su incorrecta fijación o cualquier daño físico y/o material que pudiera ocurrir debido a su incorrecta fijación.
  • Page 57 USER MANUAL / MANUAL DE USUARIO – MICROSTAR 3) Fije firmemente la columna a la base del estativo. 4) Deslice el cobertor plástico a través del extremo de la columna y sosténgalo a la altura deseada con la arandela correspondiente. Page 57 of 80 INMANUUML019 USER MANUAL/M.
  • Page 58 USER MANUAL / MANUAL DE USUARIO – MICROSTAR 5) Inserte la columna telescópica a través de su cobertura desajustando previamente los tornillos Allen de 3/16’’. 6) Coloque la arandela y el tornillo de seguridad en el extremo de la columna. Ajuste con una llave fija de 14 mm.
  • Page 59: Instalacion Del Cabezal A Brazo

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR 9) Desajuste los 3 tornillos Allen de 3/16’’ del extremo de la columna. 10) Coloque el brazo del microscopio como se muestra en la figura. Debe obtenerse un calce perfecto con la columna. Ajuste los 3 tornillos del extremo de la columna con una llave Allen. 11) Siga los pasos 5 a 9 de la sección 4.4 para la instalación del cabezal, binocular y oculares.
  • Page 60 USER MANUAL / MANUAL DE USUARIO – MICROSTAR Freno Progresivo (G) Coloque la arandela gruesa (A) en el perno del ángulo de 60º. Desajuste el freno progresivo (G), deberá colocarlo al mínimo nivel. Luego coloque el ángulo de 60º al brazo del microscopio. Continúe colocando la arandela fina (B) en el brazo, como se ve en la imagen anterior.
  • Page 61: Instalacion Del Binocular / Sistema De Video

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR Coloque el tornillo tensor (D) y ajústelo a su máximo utilizando una llave Allen correspondiente según la imagen a la izquierda. Tornillo embellecedor Tornillo seguridad (F) Coloque el tornillo embellecedor (E) y ajústelo completamente. Finalmente ajustara el tornillo de seguridad (F), también hasta su máximo.
  • Page 62: Instalacion Cables De Video

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR Si el microscopio dispone de sistema de video, monte sobre el cabezal el sistema de video, y luego monte el binocular. En ambos casos el tornillo de ajuste debe ser liberado para encastrar las partes.
  • Page 63 USER MANUAL / MANUAL DE USUARIO – MICROSTAR El cable especialmente diseñado contiene 1 ficha HDMI macho para conectar al sistema de video, y 2 fichas de alimentación DC-PLUG para alimentar el sistema de video y la luz integrada. Uno de los cables de alimentación es levemente más largo, este cable debe ser conectado al sistema de luz para mantener la tensión de los cables al mínimo.
  • Page 64: Operación - Funciones

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR 5. OPERACIÓN – FUNCIONES 5.1 OPERACIÓN DEL MICROSCOPIO En esta sección se detalla el funcionamiento del equipo. Este equipo debe ser operado sólo por personal entrenado en la utilización de este tipo de microscopios.
  • Page 65: Conexiones

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR 3) Si el brazo del microscopio está en su máxima altura, el iluminador se apaga para mantener el equipo en posición de espera (Stand By). Cuando el brazo desciende, el iluminador enciende automáticamente. 4) Apague la fuente de luz presionando el botón de encendido/apagado que se ubica en el cabezal.
  • Page 66: Fuente De Iluminacion

    5.3 FUENTE DE ILUMINACION El Microscopio Ecleris Microstar OM-200 dispone de un módulo de luz integrada al cabezal del microscopio. Desde este módulo se puede apagar o encender la luz, variar la intensidad de la misma, seleccionar diferentes niveles de diafragma para disminuir el campo iluminado y seleccionar diferentes filtros de luz.
  • Page 67: Ajuste De La Distancia Interpupilar

    55 y 75 mm. 5.5 AJUSTE DE LA CORRECCION DIOPTRICA El Microscopio Ecleris Microstar OM-200 posee una corrección dióptrica independiente para ambos oculares. El ajuste se realiza girando los oculares hacia el signo + o el signo –.
  • Page 68: Movimiento Y Transporte

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR 6. MOVIMIENTO Y TRANSPORTE En el caso del modelo de microscopio OM-200F con estativo de piso, está montado sobre 4 ruedas con frenos independientes, que permiten mover el microscopio una distancia suficiente para ubicar la mejor posición de trabajo requerida.
  • Page 69: Movimiento Rotacional Del Cabezal

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR Para equilibrar el peso del brazo pantográfico primeramente asegúrese que el bloqueo del brazo esta liberado. Seguidamente posicione el brazo en posición horizontal utilizando el freno superior (a una altura media) y ajuste o desajuste la compensación del brazo utilizando una llave Allen, de forma que ajuste el balance adecuado del brazo y los accesorios instalados.
  • Page 70: Movimiento De Giro Del Cabezal

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR 6.4 MOVIMIENTO DE GIRO DEL CABEZAL El cabezal puede girar sobre el eje de la horquilla, permitiendo un mejor posicionamiento de la dirección del centro óptico, en relación al objetivo observado. El rango de movimiento permitido es de 0-360º.
  • Page 71: Movimiento De Balanceo Del Cabezal (Movimiento Basculante)

    6.6 TRANSPORTE DEL MICROSCOPIO El Microscopio Ecleris Microstar OM-200 ha sido diseñado para ser trasladado cortas distancias dentro del recinto médico. Si es necesario transportarlo grandes distancias, debe prestarse especial atención a las siguientes precauciones: ...
  • Page 72: Montaje Del Soporte Monitor

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR 6.7 MONTAJE DEL SOPORTE MONITOR Coloque el soporte para monitor en el antebrazo. Siga los pasos que se citan a continuación para un correcto montaje: 1. Desenrosque la tapa circular superior del antebrazo utilizando una herramienta plástica para no dañar la pintura.
  • Page 73 USER MANUAL / MANUAL DE USUARIO – MICROSTAR Page 73 of 80 INMANUUML019 USER MANUAL/M. USO OM-200 V.2022.05 ENG/ESP US...
  • Page 74: Mantenimiento

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR 7. MANTENIMIENTO Para conservar el funcionamiento óptimo del Microscopio Ecleris Microstar OM-200 se recomienda realizar una revisión anual del equipo. Este procedimiento deberá incluir:  Verificar giros y movimientos para evaluar el nivel de lubricación de los mismos.
  • Page 75: Cambio De Fusible

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR  Cables en mal estado, rotos o cortados.  Mala conexión del cable con el enchufe.  Pines de conexión oxidados. 7.3 CAMBIO DE FUSIBLE Desconecte el cable de alimentación de la red eléctrica. 1) Desconecte el cable de alimentación de la red eléctrica.
  • Page 76: Especificaciones Técnicas

    USER MANUAL / MANUAL DE USUARIO – MICROSTAR 4) Retire el fusible dañado y reemplácelo por el fusible de repuesto que se encuentra en el mismo zócalo. Utilice fusibles de idénticas características eléctricas y de seguridad que el fusible original, según se indica en el rotulado del equipo. 5) Introduzca el zócalo hasta escuchar un “click”.
  • Page 77 USER MANUAL / MANUAL DE USUARIO – MICROSTAR CONSUMO 160 VA TEMPERATURA DE COLOR 6000 K aprox. VIDA UTIL DEL SISTEMA DE LEDS Aprox. 50000 horas REFRIGERACION Forzada DIMMER Electrónico BRAZO PANTOGRAFICO TIPO Compensación de pesos: WBS-Weight Balance System MOVIMIENTOS DE ROTACION Sistema con cojinetes de rodillos proximales y distales CONEXIONES...
  • Page 78 USER MANUAL / MANUAL DE USUARIO – MICROSTAR CONDICIONES DE SERVICIO 10 – 40 ºC TEMPERATURA 35 – 75 % humedad relativa HUMEDAD 700 – 1060 hPa PRESION ATMOSFERICA CONDICIONES DE ALMACENAMIENTO Y TRANSPORTE -30 – 50 ºC TEMPERATURA 10 – 95 % humedad relativa HUMEDAD 500 –...
  • Page 79: Solución De Problemas

    Si no puede solucionar el inconveniente, contacte a su distribuidor local u oficina de ECLERIS más cercana y solicite servicio técnico Page 79 of 80 INMANUUML019 USER MANUAL/M. USO OM-200 V.2022.05 ENG/ESP US...
  • Page 80: Servicio Técnico

    Se deberá efectuar el envío con el embalaje original para evitar que se dañe el equipo durante el traslado. ECLERIS no se responsabiliza por aquellos daños o defectos originados durante el transporte que sean vinculados a un embalaje deficiente. GARANTIA ECLERIS declara que el Microscopio Ecleris Microstar OM-200 ha pasado su Control de Calidad y no evidenció...

This manual is also suitable for: