Madas FM Instruction Manual

Gas filter
Hide thumbs Also See for FM:

Advertisement

Pressione massima di esercizio
Maximum operating pressure
Pression maximum de fonctionnement
Presión máxima de funcionamiento
Attacchi filettati
Threaded connections
Raccords filetés
Conexiones roscadas
Attacchi flangiati
Flanged connections
Raccords à brides
Conexiones embridadas
Norma di riferimento
Reference standard
Norme de référence
Patrón de referencia
In conformità a
In conformity with
Conforme a
Conforme
FILTRO PER GAS / GAS FILTER / FILTRE POUR GAZ / FILTRO PARA GAS
I T
* su richiesta
con flange girevoli
Regolamento (UE)
2016/426
Direttiva PED
2014/68/UE
FM-FGM
E N
DN 15 - DN 20 - DN 25 - DN 32 - DN 40 - DN 50
DN 25* - DN 32 - DN 40 - DN 50
* with swivel flanges
on request
Regulation (EU)
2016/426
PED Directive
2014/68/EU
Madas Technical Manual - 6|6.2 - REV. 0 of 10
CE-51AR1070
0051
0497
MADE IN ITALY
F R
2 - 6 bar
* sur demande
avec brides tournantes
EN 126
Règlement (UE)
2016/426
Directive PED
2014/68/UE
S
C
eCtion
hapter
6
6.2
E S
* bajo petición
con bridas locas
Reglamento (UE)
2016/426
Directiva PED
2014/68/UE
Oct 2018 - FM-FGM
th

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Madas FM

  • Page 1 Reglamento (UE) In conformità a 2016/426 2016/426 2016/426 2016/426 In conformity with Conforme a Direttiva PED PED Directive Directive PED Directiva PED Conforme 2014/68/UE 2014/68/EU 2014/68/UE 2014/68/UE Madas Technical Manual - 6|6.2 - REV. 0 of 10 Oct 2018 - FM-FGM...
  • Page 2: Technical Data

    • Assemble the device by flanging it, with the due seals, onto the plant with pipes whose flanges are consistent with the connection being attached. The gaskets must be free from defects and must be centred between the flanges; FM-FGM Madas Technical Manual - 6|6.2 - REV. 0 of 10 Oct 2018...
  • Page 3 4. OPSO series MVB/1 MAX shut off valve 9. SM remote jerk ON/OFF valve lever control 5. RG/2MC pressure regulator 10. Expansion joint/anti-vibration mount discharge in open air FM-FGM Madas Technical Manual - 6|6.2 - REV. 0 of 10 Oct 2018...
  • Page 4: First Start-Up

    The warranty also excludes maintenance work, the assembly of devices of other manufacturers, making changes to the device and natural wear. FM-FGM Madas Technical Manual - 6|6.2 - REV. 0 of 10 Oct 2018...
  • Page 5: Rating Plate Data

    • Follow the same procedure in the diagrams on pages 32 and 33 to calculate the pressure drop of the filters to the various filtering points (50 µm -20 µm -10 µm). FM-FGM Madas Technical Manual - 6|6.2 - REV. 0 of 10 Oct 2018...
  • Page 6 Proximity sensor features • Maximum voltage: 30 Vdc • Maximum power: 100 mA • Protection degree: IP55 • Protection way: EEx ia IIC T6 • Cable length: 2 m FM-FGM Madas Technical Manual - 6|6.2 - REV. 0 of 10 Oct 2018...

This manual is also suitable for:

Fgm