Thank you for purchasing a Shimaden PAC11P Series Single-Phase Thyristor Power Regulator.
After making sure the product fits the desired description, you should carefully read the instructions and get a good understanding of
the contents before attempting to operate the equipment.
Request
The instruction manual should be kept in a handy place where the end user can refer to it when necessary.
Preface
The instruction manual has been prepared for those involved in setup, wiring, operation or routine maintenance of PAC11P
Series equipment.
The manual provides information concerning mounting, wiring and precautions when working with PAC11P Series equipment.
You should therefore keep it in a handy place to refer to when operating and handling the equipment.
Be sure to observe all precautions and adhere to the procedures provided in the manual.
Safety rules, precautions concerning equipment damage, additional instructions and notes are written based on the following
headings.
Matters that could result in injury or death if instructions are not followed.
WARNING
Matters that could result in equipment damage if instructions are not followed.
CAUTION
Additional instructions and notes
Note
PAC11P Series instrument is designed to control heater power, etc., used by industrial equipment. It should not be used for nuclear power
generation, traffic control, communications or medical equipment. You should either take appropriate safety measures or avoid using for
control that could have a serious effect on human life. The manufacturer shall not be liable for an accident that results if used without
taking appropriate safety measures.
1. The power regulator should be used so the terminal elements in the control box, etc., are not touched by human beings.
2. The power regulator should not be used as a switch.
Even if output is zero, power is present in the capacitors and resistors of the output circuit, and could result in accident involving human
life or serious bodily injury due to electrical shock.
3. Radiation fins and chassis become extremely hot. Never touch the radiation fins or chassis. Doing so could result in burn injury.
4. Do not supply power when wiring. Doing so could result in electrical shock.
5. Do not touch terminal elements or other charged parts while conducting electricity. Also, do not introduce foreign objects or matter into
the equipment.
If a foreign object or matter accidentally gets inside, be sure to turn off the power and make sure all is safe before introducing tools or
your hands.
If there is danger of damage to any peripheral device or equipment due to failure of the power regulator, you should take appropriate
safety measures such as mounting a rapid fuse or overcurrent circuit breaker.
1. Concerning the
alert symbol on the power regulator s plate, a
of the device.
The symbol is provided to prompt you to employ special care not to touch the device because doing so could result in electrical shock if
parts that conduct power are touched when power is present, or could result in burn injury if touched when hot, etc.
2. Provide a switch or breaker as a means of cutting off power for external power circuit connected to the power terminal of the device.
Mount a switch or breaker near the controller where the operator can get to it easily and label it as an electrical breaker for the device.
3. Be sure to securely fasten conductor cable connections before using.
Failure to do so could result in burning from overheating due to contact resistance.
4. Be sure power supply voltage and frequency do not exceed the rating.
5. Do not apply voltage/current other than rated input to the input terminal.
Doing so could shorten the life of the product or result in equipment failure.
6. Voltage/current of load connected to the output terminal should not exceed the rating.
Using voltage/current that exceeds the rating could shorten the life of the device by raising the temperature, and could result in
equipment failure.
7. Be sure to mount the terminal cover that comes with the device after wiring.
8. The user should absolutely not modify or use the device in any way other than it was intended to be used.
9. Be sure to observe the notes and precautions provided in the manual to use the device safely and maintain its reliability.
Note: Shimaden shall bear no responsibility, monetarily or otherwise, for accident or damages caused by failure to observe warnings,
notes and precautions contained in the instruction manual.
PAC11P Series
Single-Phase Thyristor Power Regulator
Instruction Manual
WARNING
WARNING
alert symbol is printed on the label applied to the outer surface
1
MPA011P-E01-A
Apr. 2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PAC11P Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Shimaden PAC11P Series

  • Page 1 WARNING PAC11P Series instrument is designed to control heater power, etc., used by industrial equipment. It should not be used for nuclear power generation, traffic control, communications or medical equipment. You should either take appropriate safety measures or avoid using for control that could have a serious effect on human life.
  • Page 2: Table Of Contents

    Contents 1. Ordering information ································································· 3 1-1. Preliminary check ·········································································· 3 2. Panel part names and control terminals ········································ 4 3. External dimensions / terminal dimensions / weight ························· 4 4. Setup location ········································································· 5 5. Mounting ················································································ 5 6. Terminal arrangement and wiring example ···································· 6 6-1.
  • Page 3: Ordering Information

    1. Ordering information 1-1. Preliminary check The equipment has undergone sufficient quality control inspections, but you should check the specification code, inspect the equipment and confirm you have all the accessories to make sure nothing is missing or damaged. Compare the specification code on the case with the following to make sure it is the product you ordered. Ordering information Item Code...
  • Page 4: Panel Part Names And Control Terminals

    2. Panel part names and control terminals 3. External dimensions / terminal dimensions / weight 20A, 30A Weight: approx. 1.1kg 45A, 60A Weight: approx. 1.9kg (96) Φ5.5 Φ5.5 (129) 2-M4 2-M5 (134) (98) Unit: mm...
  • Page 5: Setup Location

    4. Setup location The device is designed to be used under the following conditions. Observe the following environmental conditions when using: 1) Indoor use 2) Elevation: Max. 2000 m 3) Temperature range: -10 to 50°C 4) Humidity range: Max. 90% RH Must be no dew condensation. 5) Transient overvoltage category: II 6) Pollution class: 2 (IEC 60664) CAUTION...
  • Page 6: Terminal Arrangement And Wiring Example

    6. Terminal arrangement and wiring example CAUTION Do not supply power when wiring. Doing so could result in electrical shock. Do not touch terminal elements or other charged parts while conducting electricity. This unit requires separate wiring for the main circuit (power supply for the load) and the control circuit power supply. 6-1.
  • Page 7: For Contact Input

    6-2. For contact input For use with Standard features Contact Signal Control Input Terminals External Power Adjuster External Power Adjuster Terminals B 10kΩ □ when not used, R1-R3 shor t-circuited. Control Circuit Power Input Terminals 100 to 240V AC Earthing Terminals Rapid Fuse Power Supply 100 to 240V AC...
  • Page 8: Control Mode Output Waveforms

    : See “3.External dimensions / terminal dimensions / weight” The contents of this manual are subject to change without notice. Temperature and Humidity Control Specialists Head Office: 2-30-10 Kitamachi, Nerima-ku, Tokyo 179-0081 Japan Phone: +81-3-3931-7891 Fax: +81-3-3931-3089 E-MAIL: exp-dept@shimaden.co.jp URL: https://www.shimaden.co.jp...