  • Page 1 Trus-T-Lift™ 750 Owners Operation Manual Copyright 2016 Revision A – Aug 15, 2016...
  • Page 2: Table Of Contents

    No Power to the lift. Lift will Not Operate ............... 7 Lift Runs Up and Not Down ..........Error! Bookmark not defined. Lift Runs Up and Down but Doors or Gates will Not Unlock .... Error! Bookmark not defined. RAM Manufacturing Ltd. 1-800-563-4382 P a g e...
  • Page 3: Introduction

    The lift is intended for use by people and not to be used for cargo or other purposes. Lifting capacity is up to a maximum of 750 lb. unless otherwise noted on the lift and in RAM’s supplied documentation. (DO NOT OVERLOAD THE LIFT).
  • Page 4: Operating Instructions

    DOWN paddle and the carriage will stop immediately. Section 4: Emergency Stop Switch and Key Switches You can also stop the lift by pressing the red STOP button (See Figure 1 below). To release, simply pull out the button. RAM Manufacturing Ltd. 1-800-563-4382 P a g e...
  • Page 5: Top Drive Manual Crank Operation

    If you are unable, or choose not to, use the manual crank to assist in lowering the platform to assist someone in egress from the lift please note that there may be significant risk of injuring yourself and/ or the passenger and RAM would recommend contacting local emergency services to support your efforts and avoid injury.
  • Page 6: 90 Deg Manual Crank Access

     After the lift platform reaches the desired landing or level, reverse input shaft approximately 5 rotations to relieve the load on the gearbox and drive interface and then allow the biasing spring to return the manual crank to disengaged position (as shown in figure 11-4). RAM Manufacturing Ltd. 1-800-563-4382 P a g e...
  • Page 7 TRUS<T>LIFT™ 750 OWNERS OPERATION MANUAL REVISION A, 16AUG2016 Manual crank returns to disengaged position RAM Manufacturing Ltd. 1-800-563-4382 P a g e...
  • Page 8: Maintenance

    If you do not have a copy of the maintenance manual please contact RAM to obtain one. Warning Failure to observe and complete the required maintenance for your lift product will render the warranty null and void and may present significant risk that could lead to injury or death.
  • Page 9: Lift Runs Up And Not Down

    Verify the current being drawn by the unit by using a clamp-on current meter or multimeter. It should be less than 13Amps at full load. Check the adjustment on the sliders – ask RAM for procedure if you do not know how to do this.