Carrier RHV036 Installation Instructions Manual
Carrier RHV036 Installation Instructions Manual

Carrier RHV036 Installation Instructions Manual

Single package rooftop heat pump with r-410a refrigerant
Table of Contents

Advertisement

CONTENTS
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . 1
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rated Indoor Airflow . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Jobsite Survey . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Step 1 - Plan for Unit Location . . . . . . . . . . . . 7
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Step 3 - Inspect Unit . . . . . . . . . . . . . . . . . . . . . 7
Step 4 - Provide Unit Support . . . . . . . . . . . . . 7
• ALTERNATE UNIT SUPPORT (IN LIEU OF CURB OR
Step 5 - Field Fabricate Ductwork . . . . . . . . . . 9
HEATERS
Step 6 - Rig and Place Unit . . . . . . . . . . . . . . . 9
Ductwork (when required) . . . . . . . . . . . . . . 10
OPTION)
and Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
FERED ON RHV MODELS: NON-POWERED AND
VOLT GFCI (GROUND-FAULT CIRCUIT-INTER-
RUPTER) DUPLEX RECEPTACLE RATED AT 15-A
BEHIND A HINGED WATERPROOF ACCESS COV-
ER, LOCATED ON THE END PANEL OF THE UNIT.
(SEE FIG. 21.)
• FACTORY OPTION THRU-BASE CONNECTIONS
• UNITS WITHOUT THRU-BASE CONNECTIONS
• FIELD CONTROL WIRING
RHV 036-072
Single Package Rooftop Heat Pump
with R-410A Refrigerant
Installation Instructions
Page
RHV-036-072-01SI
X (Factory Option) . . . . . . . . . . . 26
®
• INPUTS
Controller Options . . . . . . . . . . . . . . . . . . . . . . 40
Smoke Detectors . . . . . . . . . . . . . . . . . . . . . . . 40
• SMOKE DETECTORS
Step 13 - Install Accessories . . . . . . . . . . . . 40
Step 14 - Fan Speed Set Up . . . . . . . . . . . . . 42
Typical Unit Piping . . . . . . . . . . . . . . . . . . . . . . 43
Pre-Start and Start-Up . . . . . . . . . . . . . . . . . . . 44
START-UP CHECKLIST. . . . . . . . . . . . . . . . . CL-1

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical
shock or other conditions which may cause personal injury
or property damage. Consult a qualified installer, service
agency, or your distributor or branch for information or
assistance. The qualified installer or agency must use
factory-authorized kits or accessories when modifying this
product. Refer to the individual instructions packaged with
the kits or accessories when installing.
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloths for brazing operations and
have a fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions attached to
the unit. Consult local building codes and appropriate
12-21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RHV036 and is the answer not in the manual?

Questions and answers

Summary of Contents for Carrier RHV036

  • Page 1: Table Of Contents

    RHV 036-072 Single Package Rooftop Heat Pump with R-410A Refrigerant Installation Instructions • THERMOSTAT CONTENTS • UNIT WITHOUT THRU-BASE CONNECTION KIT Page • HEAT ANTICIPATOR SETTINGS SAFETY CONSIDERATIONS ....1 •...
  • Page 2: Model Number Nomenclature And

    WARNING signifies hazards which could result in personal MODEL NUMBER RATED INDOOR AIRFLOW (CFM) injury or death. CAUTION is used to identify unsafe RHV036 1200 practices, which may result in minor personal injury or product and property damage. NOTE is used to highlight...
  • Page 3 MODEL SERIES Position Number R = Rooftop H = Heat Pump Type V = 14 SEER (036-060) 15 IEER (072) Standard Efficiency 036 = 36,200 BTUH = 3 Tons 048 = 49,500 BTUH = 4 Tons 060 = 60,500 BTUH = 5 Tons 072 = 71,000 BTUH = 6 Tons Nominal Cooling Capacity K = 208/230-1-60...
  • Page 4 Fig. 2 — RHV 036-072 Unit Dimensional Drawing...
  • Page 5 Fig. 2 — RHV 036-072 Unit Dimensional Drawing (cont)
  • Page 6 Fig. 2 — RHV 036-072 Unit Dimensional Drawing (cont)
  • Page 7: Installation

    INSTALLATION 4. Prepare bottom condensate drain connection to suit planned condensate line routing (refer to Step 10 for Jobsite Survey details) 5. Rig and place unit Complete the following checks before installation. 6. Install outdoor air hood 1. Consult local building codes and the NEC (National 7.
  • Page 8 ROOF CURB NOTES: POWER WIRING CONTROL WIRING ACCESSORY CONVENIENCE CONNECTOR PKG. ACC. GAS CONNECTION TYPE GAS FITTING ACCESSORY # 1. ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. FITTING FITTING OUTLET WIRING CONNECTOR 2. INSULATED PANELS: 25.4 [1"] THK. POLYURETHANE FOAM, 44.5 [1-3/4] # DENSITY. 14"...
  • Page 9: Slab Mount (Horizontal Units Only)

    FOR UNITS WITH ACCESSORY ELECTRIC HEATERS All installations require a minimum clearance to combustible surfaces of 1 in. (25 mm) from duct for first 12 in. (305 mm) away from unit. Outlet grilles must not lie directly below unit discharge. WARNING PERSONAL INJURY HAZARD Failure...
  • Page 10: Step 7 - Convert To Horizontal And Connect

    "B" Place All Seal Strip In Place Detail "A" 36"-54" Required Before Placing Unit On Roof Curb (914-1371) Spreader Bars Duct End "C" Side "A" See Detail "A" DIMENSIONS MAX WEIGHT UNIT RHV*036 74.5 1890 36.0 33.5 RHV*048 74.5 1890 36.0 33.5 RHV*060...
  • Page 11: Step 8 - Install Outside Air Hood

    Step 8 — Install Outside Air Hood ECONOMIZER AND 2-POSITION HOOD NOTE: If the power exhaust accessory is to be installed on ECONOMIZER HOOD AND 2-POSITION DAMPER the unit, the hood shipped with the unit will not be used and HOOD PACKAGE REMOVAL AND SETUP FACTORY must be discarded.
  • Page 12: Step 9 - Units With Hinged Panels Only

    The piping for the condensate drain and external trap can be completed after the unit is in place. (See Fig. 16.) NOTE: If the alternate bottom drain is not used check the drain plug for tightness prior to setting the unit on the roof curb.
  • Page 13: Units With Factory-Installed Non-Fused Disconnect

    Field power wires are connected to the unit at line-side Connect field power supply conductors to LINE side termi- pressure lugs on compressor contactor C and indoor fan nals when the switch enclosure cover is removed to attach contactor IFC (see wiring diagram label for control box com- the handle.
  • Page 14: Units Without Factory-Installed Non-Fused Disconnect

    UNITS WITHOUT FACTORY-INSTALLED NON-FUSED DISCONNECT Convenience Outlet GFCI When installing units, provide a disconnect switch per NEC PWD-CO Fuse (National Electrical Code) of adequate size. Disconnect Switch sizing data is provided on the unit informative plate. Locate on unit cabinet or within sight of the unit per national or local codes.
  • Page 15 GFCI Receptacle Cover - While-In-Use Not Included Weatherproof Gasket Baseplate For GFCI Receptacle Fig. 23 — Weatherproof Cover Installation UNIT CONNECT PRIMARY TRANSFORMER Non-Powered Convenience Outlet VOLTAGE CONNECTIONS TERMINALS This type requires the field installation of a general-purpose L1: RED +YEL H1 + H3 125 volt 15-A circuit powered from a source elsewhere in 208, 230...
  • Page 16: Thermostat

    conduit to the internal disconnect (if unit is so equipped) or to the external disconnect (through unit side panel). Remove one of the two knockouts located on the bottom left side of the unit control box. Use this hole for the control conduit.
  • Page 17: Unit Without Thru-Base Connection Kit

    50 to 75 ft (15 to 23 m), use no. 16 AWG insulated wire HEAT ANTICIPATOR SETTINGS [35°C (95°F) minimum]. For over 75 ft (23 m), use no. 14 Set heat anticipator settings at 0.14 amp for the first stage AWG insulated wire [35°C (95°F) minimum].
  • Page 18 Fig. 30 — Defrost Control Board Location - RHV 036-072 Electro-Mechanical Units Table 4 — RHV Defrost Board I/O and Jumper Configurations POINT NAME TYPE OF I/O CONNECTION PIN NUMBER UNIT CONNECTION NOTE INPUTS G Fan DI, 24 vac P2-3 CTB-G Y1 Cool 1 DI, 24 vac...
  • Page 19: Electric Heaters

    Defrost The defrost control mode is a time/temperature sequence. There are 2 time components: The continuous run period and the test/defrost cycle period. The temperature component is provided by Defrost Thermostat 1 and 2 (DFT1 and DFT2) mounted on the outdoor coil. The continuous run period is a fixed time period between the end of the last defrost cycle (or start of the current Heat- ing cycle) during which no defrost will be permitted.
  • Page 20: Single Point Boxes And Supplementary

    SINGLE POINT BOXES AND SUPPLEMENTARY FUSES When the unit MOCP device value exceeds 60-A, unit- mounted supplementary fuses are required for each heater circuit. These fuses are included in accessory Single Point Boxes, with power distribution and fuse blocks. The single point box will be installed directly under the unit control box, just to the left of the partition separating the indoor section (with electric heaters) from the outdoor section.
  • Page 21 Fig. 37 — Typical Control Wiring Diagram, Electro-Mechanical with W7212 (RHV 036-060 208-230/3/60 Unit Shown)
  • Page 22 Fig. 38 — Typical Control Wiring Diagram, Electro-Mechanical with W7220 (RHV 072 208-230/3/60 Unit Shown)
  • Page 23 Fig. 39 — Typical RHV 036-060 Power Wiring Diagram, 208-230V/1/60 Unit Shown RHV-036-072-01SI Specifications subject to change without notice.
  • Page 24 Fig. 40 — Typical RHV 036-072 Power Wiring Diagram, 208-230V/3/60 Unit Shown RHV-036-072-01SI Specifications subject to change without notice.
  • Page 25 Fig. 41 — Typical RHV 036-072 Power Wiring Diagram, 460-575V/3/60 Unit Shown RHV-036-072-01SI Specifications subject to change without notice.
  • Page 26: Economi$Er ® X (Factory Option)

    EconoMi$er X (Factory Option) ® User Interface Provides status for normal operation, setup parameters, The EconoMi$er X system is an expandable economizer checkout tests, and alarm and error conditions with a 2-line control system, which includes a W7220 economizer 16 character LCD display and 4 button keypad. module (controller) with an LCD and keypad (see Fig.
  • Page 27: Environmental

    ENVIRONMENTAL Table 6 — Economizer Module Operating Temperature (Left Hand Terminal Blocks) –40°F to 150°F (–40°C to 65°C). LABEL TYPE DESCRIPTION Exception of display operation down to –4°F (–20°C) with Top Left Terminal Block full recovery at –4°F (–20°C) from exposure to –40°F (–40°C) 20k NTC Mixed Air Temperature Sensor (Polarity...
  • Page 28: Interface Overview

    SENSOR (HOT) BLACK YELLOW ANALOG BROWN – ORANGE GREEN Switch POWER SUPPLY. PROVIDE DISCONNECT Label MEANS AND OVERLOAD PROTECTION AS REQUIRED. Fig. 45 — CO Sensor Wiring Switches INTERFACE OVERVIEW This section describes how to use the EconoMi$er X user ®...
  • Page 29: Setup And Configuration

    4. Press the (Enter) button to display the value of NOTE: Some parameters in the menus use the letters MA or MAT, indicating a mixed air temperature sensor location the currently displayed item. before the cooling coil. This unit application has the control 5.
  • Page 30 Table 10 — W7220 Menu Structure* PARAMETER PARAMETER EXPANDED PARAMETER NAME MENU PARAMETER DEFAULT RANGE AND Notes VALUE INCREMENT † FIRST STAGE COOLING DEMAND (Y1–IN) ECON AVAIL YES/NO YES = economizing available; the system can use outside air for free cooling when required FIRST STAGE COOLING RELAY OUTPUT ECONOMIZING YES/NO...
  • Page 31 Table 10 — W7220 Menu Structure* (cont) PARAMETER PARAMETER EXPANDED PARAMETER NAME MENU PARAMETER DEFAULT RANGE AND Notes VALUE INCREMENT † EXHAUST STAGE 2 RELAY OUTPUT Output of AUX1 O terminal Displays ON when damper position reaches programmed EXH2 OUT ON/OFF percentage set point.
  • Page 32 Table 10 — W7220 Menu Structure* (cont) PARAMETER PARAMETER EXPANDED PARAMETER NAME MENU PARAMETER DEFAULT RANGE AND Notes VALUE INCREMENT † EXHAUST FAN STAGE 1 SETPOINT Set point for OA damper position when exhaust fan 1 is powered 0 to 100%; by the economizer.
  • Page 33 Table 10 — W7220 Menu Structure* (cont) PARAMETER PARAMETER EXPANDED PARAMETER NAME MENU PARAMETER DEFAULT RANGE AND Notes VALUE INCREMENT † NONE Used for alarm for when the DA air temperature is too high. Sets 70°F to 180°F DA HI ALM 80°F (27°C) upper range of alarm;...
  • Page 34 Table 10 — W7220 Menu Structure* (cont) PARAMETER PARAMETER EXPANDED PARAMETER NAME MENU PARAMETER DEFAULT RANGE AND Notes VALUE INCREMENT † Check if outdoor temperature is below the LOW Temp Lockout on set point menu. Check if Mixed air temperature on STATUS FREEZE ALARM menu is below the Lo Set point on Advanced menu.
  • Page 35 Table 11 — Damper Minimum Position Settings and Readings on Checkout Menu DEMAND CONTROLLED VENTILATION FAN SPEED SETPOINTS CHECKOUT SENSOR) MIN POS VMAX–HS MIN POS H VMAX–HS MIN POS L VMAX–LS VENT MIN VMAX–HS VENT MAX VMAX–HS VENT MIN H VMAX–HS VENT MAX H VMAX–LS...
  • Page 36 Table 14 — Enthalpy Operation without DCV (CO Sensor) — One-Speed Fan DEMAND OUTSIDE AIR CONTROLLED GOOD TO Y1-I Y2-I FAN SPEED Y1-O Y2-O OCCUPIED UNOCCUPIED VENTILATION (DCV) ECONOMIZE High 0 v/Off 0 v/Off MIN POS Closed High 24 v/On 0 v/Off MIN POS Closed...
  • Page 37 Table 17 — Dry Bulb Operation with DCV (CO Sensor) — 2-Speed Fan DEMAND OUTSIDE AIR CONTROLLED GOOD TO Y1-I Y2-I Y1-O Y2-O OCCUPIED UNOCCUPIED SPEED VENTILATION (DCV) ECONOMIZE 0v/Off 0v/Off VENTMIN Closed 24v/On 0v/Off VENTMIN Closed HIGH 24v/On 24v/On VENTMIN Closed 0v/Off...
  • Page 38 Table 19 — Enthalpy Operation with DCV (CO Sensor) — 2-Speed Fan DEMAND OUTSIDE AIR CONTROLLED GOOD TO Y1-I Y2-I Y1-O Y2-O OCCUPIED UNOCCUPIED SPEED VENTILATION (DCV) ECONOMIZE 0v/Off 0v/Off VENTMIN Closed 24v/On 0v/Off VENTMIN Closed HIGH 24v/On 24v/On VENTMIN Closed 0v/Off 0v/Off...
  • Page 39: Enthalpy Settings

    ENTHALPY SETTINGS Initial Menu Display On initial start up, Honeywell displays on the first line and When the OA temperature, enthalpy and dew point are economizer W7220 on the second line. After a brief pause, below the respective set points, the Outdoor Air can be the revision of the software appears on the first line and the used for economizing.
  • Page 40: Controller Options

    2. Turn the assembly 90 degrees and then rotate end to 3. Press the (Enter) button. ALARM ERASED end. Make sure that the elbow fitting is pointing displays. down. See Fig. 49, Step 2. 4. Press the (Menu up/Exit) button to complete the 3.
  • Page 41 STEP 1 STEP 2 STEP 3 Fig. 49 — Completing Installation of Return Air Smoke Sensor Unit Without Economizer or Economizer 2 Position Damper 2 Position Damper Fig. 50 — EconoMi$er IV Wiring ® RHV-036-072-01SI Specifications subject to change without notice.
  • Page 42: Step 14 - Fan Speed Set Up

    Step 14 — Fan Speed Set Up UNITS WITH ELECTRO-MECHANICAL CONTROLS The Fan Speed set up controls are located on the lower section of the Unit Control Board (UCB). See Fig. 51 for location. 1. Check the job specifications for the CFM (cubic feet per minute) and ESP (external static pressure) required.
  • Page 43: Typical Unit Piping

    ESP in. wg Factory Setting: Calculator 9.0 V 1500 Field Setting: 1625 Record field setting here 1750 1875 2000 Switch Range: 2125 10.0 2250 4.1 - 7.5 2375 6.9 - 8.7 2500 7.7 - 10.0 Field Accessories: Economizer * Overlap in A, B, C switch range 1 Stage E Heat designed for maximum field adjustment potential.
  • Page 44: Pre-Start And Start-Up

    Filter LPS/LOC Drier Cooling Liquid Line DFT 1 Acutrol Acutrol Indoor Coil Outdoor Coil Strainer Accurater Heating Mode Liquid Line Fig. 53 — RHV 036-060 Piping Schematic — One-Stage Cooling Filter LPS/LOC Drier Cooling Liquid Line DFT 1 Acutrol Indoor Coil Outdoor Coil Strainer Accurater...
  • Page 46 © 2021 Carrier Lewisburg, TN 37091 USA Replaces: 52701170100 RHV-036-072-01SI Specifications are subject to change without notice.
  • Page 47: Start-Up Checklist

    START-UP CHECKLIST RHV 036-072 Single Package Rooftop Heat Pump Units (Remove and use for job file) NOTE: To avoid injury to personnel and damage to equipment or property when completing the procedures listed in this start-up checklist, use good judgment, follow safe practices, and adhere to the safety considerations/information as outlined in preceding sections of this Installation Instruction document.
  • Page 48 © 2021 Carrier Lewisburg, TN 37091 USA Replaces: 52701170100 RHV-036-072-01SI CL-2 Specifications are subject to change without notice. 12-21...