USER MANUAL
WATER VALVE ACTUATOR ZAC36 LR
Automatic shut-off actuator for your main water valve
Ÿ
Connect it to your Z-Wave® hub for full smart home control
Ÿ
Use it offline with the included leak sensor probe
Ÿ
Built-in temperature detection for instant freeze detection
Ÿ
Retrofit installation with no tools required
Ÿ
Use with " - 1 " ball valves only (close prior to installation)
Ÿ
Indoor & outdoor installation with IP66 rating (avoid direct sunlight)
Ÿ
Z-Wave® Long Range for ultra reliable no-mesh communication
Ÿ
S2 Security and SmartStart for easier inclusion
Ÿ
SPECIFICATIONS
Model Number: ZAC36 LR
Ÿ
Z-Wave® Region: US / CA / MX
Ÿ
Power: 12 V DC (1 A) power supply (included)
Ÿ
Temperature Sensor Range: -40° to 257° F
Ÿ
Sound Indicator: up to 85 dB
Ÿ
Z-Wave® Range: Up to 400 feet line of sight (up to 1300 with LR)
Ÿ
Operating Temperature: 14-122° F (-10-50° C)
Ÿ
Installation and Use: Indoor & outdoor (Ip66)
Ÿ
Standby Power Consumption: 0.12 W
Ÿ
Full Operation Power Consumption: 8.4 W
Ÿ
This product can be included and operated in any Z-Wave® network
with other Z-Wave® certified devices from other manufacturers
and/or other applications. All non-battery operated nodes within the
network will act as repeaters regardless of vendor to increase
reliability of the network. This product features the latest Security 2
(S2) framework to remove smart home network hacking risks. This
device is equipped with a unique authentication code for trusted
wireless communication.
SCAN FOR FULL INSTALLATION GUIDE
Scan the QR code with your phone's camera.
Then click on the link to access the detailed
installation guide with video instructions!
BEFORE YOU INSTALL
Install this actuator on ball valves only.
At least 1.25" space between valve handle and pipe required.
ALWAYS CLOSE THE VALVE FIRST!
Use with " - 1 " ball valves only.
Do NOT use with gate valves.
TITAN
www.getzooz.com
ask@getzooz.com
FEATURES
PAGE 1
1. CLOSE YOUR VALVE: turn the main shut-off valve to the
closed position before you start installing the Titan.
2. PREPARE YOUR ACTUATOR:
position the Titan over the valve
so that the clamp fasteners are
facing the same direction as
the valve handle, just as shown
in the drawing.
3. INSERT THE SPACER
IF NEEDED: when installing
the Titan on a low-profile valve, you'll
need to place the included spacer accessory between the
valve handle and the Titan's fork.
4. PLACE THE ACTUATOR ON THE VALVE: make sure the
Titan's fork is aligned with the handle screw and press down
so that the fork catches the screw and the clamps embrace
the pipe. Tighten the fasteners to secure the actuator on the
pipe.
S2
5. CONNECT THE LEAK DETECTOR: if you'd like to use the
offline leak detector probe (included), connect it to the jack
located on the cable next to the power supply connector (take
off the cap from the jack first!). It will trigger the valve to close
whenever a leak is detected and send a report to your Z-Wave
hub (sold separately).
6. POWER THE ACTUATOR: connect the power jack on the
included DC adapter with the Titan's power cord. Turn
clockwise until the seal cover is fully secured. Plug into a
standard 120 V receptacle. The LED will start blinking yellow.
7. CALIBRATE: Do NOT skip this step! Hold the Z-Wave®
button until the second beep sounds, then immediately
release it. Auto-calibration will start and the LED will flash
green twice when it's complete. Click the Z-Wave® button
once to open or close the valve.
INSTALLATION