USER MANUAL – XSI-B-120V-1K-3K
XSI-B-120V-1K/2K/3K
This manual Information cannot be copied or distributed totally
.
VER.2405.14- (ESP)
VER. 2405.14
ENGLISH
USER MANUAL
SOLAR INVERTER 120V
XSI-B-120-1K-12-MPP
XSI-B-120-2K-24-MPP
XSI-B-120-3K-24-MPP
INDEX
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Xmart XSI-B-120-1K-12-MPP and is the answer not in the manual?

Questions and answers

Summary of Contents for Integra Xmart XSI-B-120-1K-12-MPP

  • Page 1 INDEX USER MANUAL – XSI-B-120V-1K-3K VER. 2405.14 ENGLISH USER MANUAL XSI-B-120V-1K/2K/3K SOLAR INVERTER 120V XSI-B-120-1K-12-MPP XSI-B-120-2K-24-MPP XSI-B-120-3K-24-MPP Technical information on this manual is property of XMART  This manual Information cannot be copied or distributed totally ▪ or partially without written approval of XMART. XMART can introduce modifications in their products or manuals without further notice.
  • Page 2: Table Of Contents

    INDEX USER MANUAL – XSI-B-120V-1K-3K TABLE OF CONTENTS 1. GENERAL SAFETY INSTRUCTIONS 2. SAFETY, QUALITY AND PERFORMANCE STANDARDS 3. PARTS IDENTIFICATION 4. PRODUCT DESCRIPTION 5. INSTALLATION 6. OPERATION MODES 7. OPERATION INTERFACE (KEYBOARD & LCD) 8. STARTUP 9. CONFIGURATION 10. ERROR & ALARMS CODES / TROUBLESHOOTING 11.
  • Page 3: General Safety Instructions

    INDEX USER MANUAL – XSI-B-120V-1K-3K 1. GENERAL SAFETY INSTRUCTIONS WARNING: It is required to read and understand this manual. Follow all instructions given in this manual for starting up and operating this product. Only qualified technician must startup, operate and maintain this product. Keep manuals as a guide for future consults. Neither manufacturer, nor distributor, will never be responsible for any accident produced by lack of knowledge or negligent practices at the moment of install, starting up or maintain this product.
  • Page 4: Safety, Quality And Performance Standards

    INDEX USER MANUAL – XSI-B-120V-1K-3K 2. SAFETY, QUALITY AND PERFORMANCE STANDARDS SAFETY - LOW VOLTAGE DIRECTIVE EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013 ELECTROMAGNETIC COMPATIBILITY - EMC DIRECTIVE EN 55032: 2015 EN 61000-3-2: 2014 EN 61000-3-3: 2013 EN 55024:2010+A1:2015 CE compliant IP PROTECTION IP20 (static) QUALITY MANAGEMENT:...
  • Page 5: Parts Identification

    INDEX USER MANUAL – XSI-B-120V-1K-3K 3. PARTS IDENTIFICATION This unit is a multifunctional “off-grid” solar inverter with sine-wave output for 120Vac systems including an internal solar charger and AC charger. This unit can operate receiving energy from any of its 3 inputs: AC, Solar, and Batteries. A perfect inverter for hybrid “off-Grid” applications with capacities of 1K, 2K, and 3KVA.
  • Page 6 INDEX USER MANUAL – XSI-B-120V-1K-3K 4. PARTS IDENTIFICATION MODELS: 120V - 1K FRONT PANEL: BOTTOM PANEL: www.xmart-ups.com VER.2405.14- (ESP)
  • Page 7 INDEX USER MANUAL – XSI-B-120V-1K-3K MODEL: 120V - 2K FRONT PANEL: BOTTOM PANEL: www.xmart-ups.com VER.2405.14- (ESP)
  • Page 8 INDEX USER MANUAL – XSI-B-120V-1K-3K MODEL: 120V - 3K FRONT PANEL: BOTTOM PANEL: www.xmart-ups.com VER.2405.14- (ESP)
  • Page 9: Installation

    INDEX USER MANUAL – XSI-B-120V-1K-3K 5. INSTALLATION SAFETY INSTRUCTIONS WARNING: Before start checking information in this section, please be advised that checking and understanding safety and warning information from section 1 “Safety Instructions” is absolutely necessary. LIABILITY LIMITATION REACH AND LIABILITY LIMITATION: The preparation of the site, wiring and all protection devices must be supplied by end user and it will not be responsibility neither the inverter distributor nor the inverter technician in charge of the startup, unless it has been previously agreed.
  • Page 10 INDEX USER MANUAL – XSI-B-120V-1K-3K SITE INSPECTION AND INSTALLATION CONDITIONS REGULATIONS AND LEGAL DIRECTIVES It is necessary to check that installation site, wiring and power protection in the installation supplied by end user, fulfill technical parameters required by this manual, as well as local electrical regulation. A particular installation might accomplish with Inverter requirements but not with local directives and regulations.
  • Page 11 INDEX USER MANUAL – XSI-B-120V-1K-3K Battery Connections It is recommended to install a Circuit Breaker that can open the battery circuit for connection and disconnection to the inverter and for maintenance tasks. Make sure to install a Circuit Breaker device (fuse or breaker) on the positive battery cable. Size the breaker devices according to the maximum expected current for each inverter model.
  • Page 12 INDEX USER MANUAL – XSI-B-120V-1K-3K BATTERY BANK ARRAY 1K model operates with a 12VDC battery voltage. 2K and 3K models operate with a 24VDC battery voltage (2 x 12V batteries in series). For extended backup, additional batteries can be added in parallel as shown in the figure in this section. The more batteries connected to the inverter, the longer the backup time will be, but the battery recharge time will also increase.
  • Page 13 INDEX USER MANUAL – XSI-B-120V-1K-3K AC INPUT CONNECTION Install a Circuit Breaker on the AC input cables (phase and neutral) to protect the circuit against overcurrent and to allow for circuit connection and disconnection during installation and maintenance. Select the input breaker with a rating 30% higher than the nominal current. Select cables according to the information in the table in this section.
  • Page 14 INDEX USER MANUAL – XSI-B-120V-1K-3K AC OUTPUT CONNECTION Install a Circuit Breaker on the AC input cables (phase and neutral) to protect the circuit against overcurrent and to allow for circuit connection and disconnection during installation and maintenance. Select the input breaker with a rating 30% higher than the nominal current. Select cables according to the information in the table in this section.
  • Page 15 INDEX USER MANUAL – XSI-B-120V-1K-3K SOLAR PANELS CONNECTION IMPORTANT: Select monocrystalline or polycrystalline solar panels. When selecting and designing the solar panel array, make sure the open-circuit voltage (Voc) of the array does not exceed the maximum Voc of the inverter's PV input, as this will cause permanent damage to the inverter. Refer to the table in this section and the suggestions in Annex 1.
  • Page 16 INDEX USER MANUAL – XSI-B-120V-1K-3K COMMUNICATION PORTS USB: (Built-In) All models are equipped with a USB communication port, located under the bottom panel of the inverter. See previous image for reference on the Comm. Port location for each model. USB & RS-232: (Only for 3K Model) All models are equipped with a USB and an RS232 communication ports, located either on the left side or the right side according to the model.
  • Page 17: Operation Modes

    INDEX USER MANUAL – XSI-B-120V-1K-3K 6. OPERATION MODES This inverter can operate in 4 main modes: Stand-By: Connected to the input power sources (AC and/or Solar), but with the power switch in <OFF>. Line: Connected to the input power sources (AC and/or Solar) and with the power switch in <ON>. Battery or Inverter: Connected to the solar source and/or batteries (one of the two) and with the switch in <ON>...
  • Page 18 INDEX USER MANUAL – XSI-B-120V-1K-3K Output powered from AC input. The solar input is used to recharge the batteries: In this mode, inverter is connected to power sources, and the inverter has been turned on using the <ON> button. NORMAL MODE In this condition, inverter can recharge the batteries from either of the two Output powered from AC input.
  • Page 19 INDEX USER MANUAL – XSI-B-120V-1K-3K 7. KEYBOARD & LCD On the inverter front panel there is an operations panel, consisting of an LCD screen, status indicator LEDs, and operation buttons. LEDS DESCRIPTION: Name Description / Operation On: The output is powered from the AC input. AC / INV Status Led Blinking: The output is powered from the battery and/or solar input.
  • Page 20 INDEX USER MANUAL – XSI-B-120V-1K-3K LCD DESCRIPTION LCD screen can be divided into 4 areas to provide specific information about the inverter: La pantalla LCD se puede dividir en 4 segmentos dedicados a proporcionar información especializada sobre el inversor: 1. INPUT INFORMATION: 2.
  • Page 21 INDEX USER MANUAL – XSI-B-120V-1K-3K AC INPUT DETECTED SOLAR INPUT DETECTED CHARGER IN OPERATION (LINE MODE) INVERTER IN OPERATION (BATTERY MODE) OUTPUT POWER DELIVERED (LOAD CONNECTED TO INVERTER OUTPUT) Graphically indicates the load level (as a percentage) connected to the INVERTER output: 100%: Power delivered between 75% &...
  • Page 22 INDEX USER MANUAL – XSI-B-120V-1K-3K 8. STARTUP AND OPERATION INSPECTION BEFORE STARTUP Make sure all wires are tightly connected to terminal block. Any loose connection will produce overheating, failures, and damage to the unit. Make sure all instructions of installation sections have been performed correctly. Verify wiring and Circuit Breakers are correctly installed.
  • Page 23: Configuration

    INDEX USER MANUAL – XSI-B-120V-1K-3K 9. CONFIGURATION Configuration menu provides access to the INVERTER's adjustable functions and parameters. It is activated by pressing the ENTER button for 3 seconds. Use <UP> and <DOWN> keys to scroll through the menu. Select the desired value with the ENTER key and confirm the selection.
  • Page 24 INDEX USER MANUAL – XSI-B-120V-1K-3K AUTO-RESTART AFTER AN OVERHEATING EVENT TTD, TTE TTD: Disable (default) TTE: Enable OUTPUT VOLTAGE 110, 120 110: Sets output voltage to 110Vac 120: Sets output voltage t 120Vac (default) OUTPUT FREQUENCY 50, 60 50: Sets output frequency to 50Hz 60: Sets output frequency to 60Hz (default) AC CHARGER MAXIMUM CHARGE CURRENT: 10, 20, 30, 40...
  • Page 25 INDEX USER MANUAL – XSI-B-120V-1K-3K MAIN POWER SOURCE INTERRUPTION ALARM: AON, AOF AON: An audible alarm will sound when the main power source is interrupted. AOF: Audible alarm for main power source interruption OFF SWITCH TO BYPASS DUE TO OVERLOAD IN BATTERY MODE: byd: If an overload is detected at the output while in battery mode, the inverter output will Byd, byE turn off (default).
  • Page 26 INDEX USER MANUAL – XSI-B-120V-1K-3K 10. ERRORS & ALARMS CODES / TROUBLESHOOTING IMPORTANT: All alarm and errors are informed on the LCD by dedicated codes and symbols. ▪ ALARMS: Are usually represented by blinking codes or symbols. Audible alarm beeps are also intermittent for alarms. Alarm ▪...
  • Page 27 INDEX USER MANUAL – XSI-B-120V-1K-3K TROUBLESHOOTING PROBLEM PROBABLE CAUSE & SOLUCION Automatically shuts down during startup Issue: Batteries discharged below 11.45V (per battery). (The screen remains on for 3 seconds and then turns off) Solution: Recharge the batteries in stand-by mode or replace batteries if damaged.
  • Page 28: Specifications

    INDEX USER MANUAL – XSI-B-120V-1K-3K 11. SPECIFICATIONS XSI-B - SOLAR INVERTER 120V - (1/2) 1K-12-MPP 2K-24-MPP 3K-24-MPP Out Capacity / Capacidad de Salida (VA) 1000 VA 2000 VA 3000 VA Output Capacity / Capacidad de Salida (W) 800 W 1600 W 2400 W MAIN FEATURES / FUNCIONALIDADES 6 units max...
  • Page 29 INDEX USER MANUAL – XSI-B-120V-1K-3K SPECIFICATIONS XSI-B - SOLAR INVERTER 120V - (2/2) 1K-12-MPP 2K-24-MPP 3K-24-MPP CHARGERS (SOLAR & AC) Solar charger type / Cargador solar MPPT Charging procedure / Tipo de recarga 3 steps: 1-Constant Current (Bulk), 2-Constant Voltage, 3-Floating Data for VRLA Batteries / Datos para Baterías VRLA Bulk Charging / Voltaje cargador (Etapa Bulk) 14.1 VDC...
  • Page 30: Annex 1. Solar Panels Array

    INDEX USER MANUAL – XSI-B-120V-1K-3K ANNEX 1: SOLAR PANELS ARRAYS SOLAR PANELS ARRAYS SUGGESTED FOR: XSI-B-120V-1K-12V-MPP Suggestions based on 120W, 150W, 270W, and 320W solar panels. INVERTER (PV INPUT) PANEL TYPE SOLAR PANELS ARRAY INVERSOR (ENTRADA PV) TIPO DE PANEL ARREGLO PANELES SOLARES Range/Rango Parallel...
  • Page 31 INDEX USER MANUAL – XSI-B-120V-1K-3K SOLAR PANELS ARRAYS SUGGESTED FOR: XSI-B-120V-2K-24V-MPP. Suggestions based on 120W, 150W, and 270W panels. INVERTER (PV INPUT) PANEL TYPE SOLAR PANELS ARRAY INVERSOR (ENTRADA PV) TIPO DE PANEL ARREGLO PANELES SOLARES Range/Rango Parallel Series (Vdc) MAX.
  • Page 32 INDEX USER MANUAL – XSI-B-120V-1K-3K SOLAR PANELS ARRAYS SUGGESTED FOR: XSI-B-120V-3K-24V-MPP. Suggestions based on 100W, 120W, and 320W panels. INVERTER (PV INPUT) PANEL TYPE SOLAR PANELS ARRAY INVERSOR (ENTRADA PV) TIPO DE PANEL ARREGLO PANELES SOLARES Range/Rango Parallel Series (Vdc) MAX.
  • Page 33 INDEX USER MANUAL – XSI-B-120V-1K-3K ANNEX 2: BACKUP TABLES & RECHARGE TIMES BACKUP TABLES IMPORTANT: Backup times indicated in this section are approximate. Some of the values have been determined through laboratory tests, while others have been determined through calculations based on the discharge tables provided by the battery manufacturers. Backup times assume that Shutdown Voltage is 11.5VDC per battery.
  • Page 34 INDEX USER MANUAL – XSI-B-120V-1K-3K INVERTER: 3KVA 24VDC LOAD / BATT VOLT CONSUMO BACKUP (minutes) 1035 1620 2160 24 VDC 200 W XSI-B-120-2K-24-MPP 24 VDC 400 W 1080 24 VDC 600 W 24 VDC 800 W 24 VDC 1000 W 24 VDC 1200 W 24 VDC...
  • Page 35 INDEX USER MANUAL – XSI-B-120V-1K-3K RECHARGE TABLES IMPORTANT: The value of the recharge current from the AC and Solar charger is adjustable. It is recommended that the total recharge current (AC + Solar) never exceed 20% of the AH capacity of the battery bank (0.2C). For example, for a 100AH battery bank, a maximum total recharge current of 20A is recommended (100AH * 0.2).
  • Page 36 INDEX USER MANUAL – XSI-B-120V-1K-3K ANNEX 3. BATTERY CHARGER XMART XSI-B-120V inverters come with 2 powerful internal battery chargers. First one is connected to the AC input, while second one is connected to solar input. Both can recharge batteries either simultaneously or separately, depending on the configuration of the inverter. CHARGERS SETTINGS: Chargers used by this inverter are of modern technology and can be configured to limit maximum recharge current according to the capacity of the battery bank connected to the inverter.
  • Page 37 INDEX USER MANUAL – XSI-B-120V-1K-3K ANNEX 4. PARALLEL CONECTION – 3K MODEL PARALLEL OPERATION - 3KVA MODEL 3KVA model XSI-120-3KP-24-MPP can operate in parallel to increase capacity or to provide redundancy and more reliability to the power supply of your installation. The maximum number of units that can be installed in parallel is 6, so the maximum capacity that can be achieved in a parallel system is 18KW/14.4KW.
  • Page 38 INDEX USER MANUAL – XSI-B-120V-1K-3K 2. Before inserting the Parallel Control Board into the inverter, connect the 2-pin and 14-pin cables coming from inside the inverter, as shown in the figure on the right. These cables are exposed when removing the cover as explained in the previous step.
  • Page 39 INDEX USER MANUAL – XSI-B-120V-1K-3K It should be noted that the cables connecting the busbar to the batteries must withstand a current “X” time higher than the one going from the busbar to each inverter, where "X" is the number of inverters connected in parallel. Previous principles should also be applied to the AC input and AC output cables.
  • Page 40 INDEX USER MANUAL – XSI-B-120V-1K-3K (Note 1) PARALLEL CONTROL CABLE CONNECTION. This unit has 2 types of ports for parallel operation: • Communication Port: For continuous communication between inverters, maintaining stable and reliable operation. • Shared Current Port. With which the inverters synchronize their outputs, ensuring perfect parallel operation. For each type of port, there is a specific type of cable designed for effective parallel operation, as shown at the beginning of this annex.
  • Page 41 INDEX USER MANUAL – XSI-B-120V-1K-3K SINGLE-PHASE INSTALLATIONS www.xmart-ups.com VER.2405.14- (ESP)
  • Page 42 INDEX USER MANUAL – XSI-B-120V-1K-3K THREE-PHASE INSTALLATIONS Arrangement for 3 Inverters Inverters in Phase #1: 1 Inverters in Phase #2: 1 Inverters in Phase #3: 1 Electrical Connections Control Cables Note: Do not connect the shared current cables between inverters powered by different phases. Doing so can damage the units.
  • Page 43 INDEX USER MANUAL – XSI-B-120V-1K-3K Arrangement for 4 Inverters Inverters in Phase #1: 2 Inverters in Phase #2: 1 Inverters in Phase #3: 1 Electrical Connections Control Cables Note: Do not connect the shared current cables between inverters powered by different phases. Doing so can damage the units.
  • Page 44 INDEX USER MANUAL – XSI-B-120V-1K-3K Arrangement for 5 Inverters Inverters in Phase #1: 2 Inverters in Phase #2: 2 Inverters in Phase #3: 1 Electrical Connections Control Cables Note: Do not connect the shared current cables between inverters powered by different phases. Doing so can damage the units.
  • Page 45 INDEX USER MANUAL – XSI-B-120V-1K-3K Arrangement for 5 Inverters Inverters in Phase #1: 3 Inverters in Phase #2: 1 Inverters in Phase #3: 1 Electrical Connections Control Cables Note: Do not connect the shared current cables between inverters powered by different phases. Doing so can damage the units.
  • Page 46 INDEX USER MANUAL – XSI-B-120V-1K-3K Arrangement for 6 Inverters Inverters in Phase #1: 3 Inverters in Phase #2: 2 Inverters in Phase #3: 1 Electrical Connections Control Cables Note: Do not connect the shared current cables between inverters powered by different phases. Doing so can damage the units.
  • Page 47 INDEX USER MANUAL – XSI-B-120V-1K-3K Arrangement for 6 Inverters Inverters in Phase #1: 4 Inverters in Phase #2: 1 Inverters in Phase #3: 1 Electrical Connections Control Cables Note: Do not connect the shared current cables between inverters powered by different phases. Doing so can damage the units.
  • Page 48 INDEX USER MANUAL – XSI-B-120V-1K-3K Arrangement for 6 Inverters Inverters in Phase #1: 2 Inverters in Phase #2: 2 Inverters in Phase #3: 2 Electrical Connections Control Cables Note: Do not connect the shared current cables between inverters powered by different phases. Doing so can damage the units.
  • Page 49 INDEX USER MANUAL – XSI-B-120V-1K-3K LCD AND CONFIGURATION: To ensure proper operation of your inverters in parallel, they must be correctly configured. To do this, you should set the inverter to Standby mode and set parameters 28 and 30, as shown in the following table: For Single-Phase parallel installations: Set parameter to “PAL”, remember “SIG”...
  • Page 50 INDEX USER MANUAL – XSI-B-120V-1K-3K FAULT CODES The following error messages are available when the units operate in parallel: FAULT DESCRIPTION FAULT CODE FAULT ICON Electrical feedback protection Inconsistent internal firmware version Shared current failure CAN data loss Loss of internal network server Loss of synchronization Difference in battery voltage between inverters Voltage and/or frequency differences between AC input phases of the equipment.
  • Page 51 INDEX USER MANUAL – XSI-B-120V-1K-3K This will become the main screen of the inverters, and in some models, it can be alternated with the input and output voltage screens. For more information about available screens and handling, refer to section 8. SETUP AND OPERATION, of this manual. Turn on the input circuit breakers of each inverter.
  • Page 52 INDEX USER MANUAL – XSI-B-120V-1K-3K TROUBLESHOOTING SITUATION PROBABLE CAUSE & SOLUTION 1. Restart the inverter. 2. Check the polarity of the Line (L1, L2) and Neutral cables. 3. Ensure that the shared current and communication cables are properly Code 60 connected to all inverters in single-phase installations.
  • Page 53 INDEX USER MANUAL – XSI-B-120V-1K-3K ANNEX 5: XMART LiFePO4 BATTERIES. CONNECTION AND SETTING INTRODUCTION TO XMART LiFePO4 BATTERIES These batteries belong to the Lithium-Ion battery group, specifically the LiFePO4 type (Lithium Iron Phosphate, LFP). They are the safest type of Lithium batteries, provided that all safety, storage, and operation regulations are followed to avoid overheating, fire, and/or explosions.
  • Page 54 INDEX USER MANUAL – XSI-B-120V-1K-3K NOTE 1: CHARGING CURRENTS FOR XMART LIFEPO4 12.8/100AH BATTERIES The maximum charging current depends on the environment temperature. It is very important to set the maximum current of the battery charger depending on the site temperature and, above all, to respect the temperature ranges within which the batteries should not be charged.
  • Page 55 INDEX USER MANUAL – XSI-B-120V-1K-3K WARRANTY & SUPPORT Support: If a failure or problem is detected please check troubleshooting section in user manual. If problem cannot be solved, please contact authorized service center or authorized dealer. Batteries: Rechargeable batteries can be charged and discharged hundreds of times. However, they will eventually wear out. This is not a defect or failure so that batteries wear out is not covered by this warranty.
  • Page 56 EUROPE LATAM Miami, FL 33172. USA Barcelona, Sabadell 08202. Spain Santiago de Chile, Chile sales@xmart-ups.com sales@xmart-ups.com sales@xmart-ups.com...