  • Page 1 Cellular Blood Pressure Monitor Traditional Paper Manual Online manual and FAQs at the link below. GREATERGOODS.COM/0042...
  • Page 2: Table Of Contents

    Table Of Contents 2 Introduction 3 Device 5 Batteries 6 Setting Up Your Monitor 7 Taking a Measurement 10 Memory 11 Irregular Heartbeat Detector / Indications for Use 12 Tips / Upkeep 13 FAQ 15 Warnings 18 Troubleshooting 19 Device Specifications 20 EMC Guidance 23 FCC Statement 24 Warranty...
  • Page 3: Introduction

    Introduction Thanks so much for using a Greater Goods blood pressure monitor! This monitor was designed for ultimate ease-of-use and accuracy—making home health monitoring more approachable than ever before. This model detects blood pressure measurements by utilizing the oscillometric method, which turns blood pressure into a digital reading.
  • Page 4: Device

    Device Cuff Button Down Button Start/Stop Air Hose LCD Display Button Air Hose AC Adapter Plug Plug (adapter not included) Battery Compartment Box Includes: Blood Pressure Monitor, Cuff, 4xAA Batteries, User Manual...
  • Page 5 Device (cont.) ICON DESCRIPTION EXPLANATION Systolic blood pressure High blood pressure Diastolic blood pressure Low blood pressure Pulse display Heartbeats per minute Indicates it is in memory mode and Memory which reading it is. mmHg Measurement unit of blood pressure Batteries are running low and need to Low battery be replaced...
  • Page 6: Batteries

    Batteries 1. Open the battery compartment cover on the back of the device. 2. Install 4 AA batteries that match the correct polarity. NOTE: Always use AA batteries with this device. 3. Replace the batteries whenever shows, the display dims, or the display does not light up. NOTE: Do not heat or deform the batteries, or dispose of them in fire.
  • Page 7: Setting Up Your Monitor

    Setting Up Your Monitor 1. Every time you insert or replace batteries in the monitor, it will automatically start searching for a cellular network to connect to. The device will spend up to 5 minutes looking for a network to connect to, and the screen will look like this as it is searching: 2.
  • Page 8: Taking A Measurement

    Taking a Measurement Fastening the Cuff 1. Fasten the cuff on your upper arm, then align the tube off-center, toward the inner side of the arm in line with the little finger. 2. The cuff should be snug but not too tight. You should be able to insert one finger between the cuff and your arm.
  • Page 9 Taking a Measurement (cont.) Start the Measurement 1. With the monitor off, press the START/STOP button to turn on the monitor. 2. After the monitor is turned on, the reading will start automatically. 3. When the measurement is completed, the data transmission process will begin. If your results are successfully sent, the symbols “...
  • Page 10 Taking a Measurement (cont.) This product uses the Oscillometric Measuring method to detect blood pressure. Before every measurement, the unit establishes a “zero pressure” equivalent to the atmospheric pressure. When the arm cuff starts inflating, the unit also detects pressure oscillation generated by beat-to-beat pulsatile, which will determine systolic and diastolic pressure, as well as pulse rate.
  • Page 11: Memory

    Memory 1. When the monitor is off press the UP or DOWN button, and the monitor will display the most recent record. 2. Measurements can be cycled through using the UP or DOWN buttons. Pressing UP will cycle through records from newest to oldest, and pressing DOWN will cycle from oldest to newest.
  • Page 12: Irregular Heartbeat Detector / Indications For Use

    Irregular Heartbeat Detector This Blood Pressure Monitor is equipped with an Irregular Heartbeat Detector (IHB). During each measurement, this equipment records the heartbeat intervals and works out the standard deviation. If the calculated value is larger than or equal to 15, this equipment will light up the IHB symbol on the screen when displaying the results.
  • Page 13: Tips / Upkeep

    Tips / Upkeep Tips for Measurement Inaccuracy can occur if measurements are taken under the following circumstances: • Measuring within 1 hour of eating or drinking. • Measuring within 1 hour of smoking. • Measuring 20 minutes after taking a bath or shower. •...
  • Page 14: Faq

    What is the difference between systolic pressure and diastolic pressure? When ventricles contract and pump blood out of the heart, the blood pressure reaches its maximum value in the cycle, which is called systolic pressure. When the ventricles relax, the blood pressure reaches its minimum value in the cycle, which is called diastolic pressure.
  • Page 15 FAQs (cont.) Does it matter which arm I use when measuring? It is acceptable to use either arm when measuring. However, to obtain the most consistent readings possible, it is suggested that you use the same arm each time you measure your blood pressure. What is the standard blood pressure classification? The chart below is the standard blood pressure classification by the American Heart Association (AHA).
  • Page 16: Warnings

    Warnings • This device is intended for indoor, personal, home use. This device is not intended for use in a public environment. • Do not use this device during patient transportation. • Consult your physician before measuring blood pressure, especially if you have any of the following conditions: •...
  • Page 17 Warnings (cont.) • If the cuff reaches 300 mmHg, the unit will automatically deflate. Should the cuff not deflate when the pressure reaches 300 mmHg, detach the cuff from the arm and press the START/STOP button to stop inflation. • Do not touch the battery output and the patient simultaneously. •...
  • Page 18 Warnings (cont.) • This equipment is not AP/APG equipment and is not suitable for use in the presence of a flammable anesthetic mixture with air with oxygen or nitrous oxide. • Do not disassemble or attempt to repair this device or any of its components.
  • Page 19: Troubleshooting

    Troubleshooting PROBLEM SYMPTOM REASON SOLUTION No power Display will not Batteries are drained Replace with new light up batteries Batteries are inserted Insert the batteries incorrectly correctly Low batteries Display is dim or Batteries are low Replace with new batteries icon is showing Error E1 appears...
  • Page 20: Device Specifications

    Device Specifications Power Supply Battery powered mode: 6VDC 4xAA batteries AC adapter powered mode: 6V 1A (adapter not included) Display Mode Digital LCD display. Viewing Area: 73x49mm Measurement Mode Oscillometric testing mode Measurement Range Rated cuff pressure: 0~299mmHg (0kPa~39.9kPa) Measurement pressure: SYS: 60~230mmHg (8.0kPa~30.7kPa) DIA: 40~130mmHg (5.3kPa~17.3kPa) Pulse value: 40-199 beat/minute...
  • Page 21: Emc Guidance

    EMC Guidance EMC Guidance The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare environments. Warnings: (1) Don’t near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high. (2) Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation.
  • Page 22 EMC Guidance (cont.) Table 2 Guidance and manufacturer’s declaration – electromagnetic Immunity IMMUNITY TEST IEC 60601-1-2 TEST LEVEL COMPLIANCE LEVEL Electrostatic ±8 kV contact ±8 kV contact discharge (ESD) ±2 kV, ±4kV, ±8 kV, ±15 kV air ±2 kV, ±4kV, ±8 kV, ±15 kV air IEC 61000-4-2 Electrical fast No application...
  • Page 23 EMC Guidance (cont.) Table 3 Guidance and manufacturer’s declaration – electromagnetic Immunity Radiated RF IEC61000-4-3 (Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment) TEST BAND SERVICE MODULATION MAXIMUM DISTANCE IMMUNITY TEST COMPLIANCE FREQUENCY (MHZ) POWER(W) LEVEL (V/m) LEVEL (V/m) (MHZ) TETRA 400...
  • Page 24: Fcc Statement

    FCC Statement FCC Statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 25: Warranty

    Warranty Activate Your Warranty Please visit greatergoods.com/0042 to activate your product’s warranty and access lifetime support. Your monitor is warranted by the manufacturer against defects in materials and workmanship for two (2) years from the original purchaser from the date of purchase.
  • Page 26 Notes...
  • Page 27 Notes...
  • Page 28: Contact Us

    CONTACT US 800.481.0233 info@greatergoods.com greatergoods.com/0042 DISTRIBUTED BY: Greater Goods, LLC. | 4427 Chouteau Ave. | St. Louis, MO 63110...