ANCEL S100 User Manual

ANCEL S100 User Manual

Automotive diagnostic smoke leak detector

Advertisement

User's Manual
Automotive Diagnostic Smoke Leak Detector
OBDSPACE TECHNOLOGY CO., LTD
Address: D03, Block A, No. 973 Minzhi Ave., Longhua District, Shenzhen, Guangdong, China
Email: support@anceltech.com
Website: www.anceltech.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S100 and is the answer not in the manual?

Questions and answers

Summary of Contents for ANCEL S100

  • Page 1 User’s Manual Automotive Diagnostic Smoke Leak Detector OBDSPACE TECHNOLOGY CO., LTD Address: D03, Block A, No. 973 Minzhi Ave., Longhua District, Shenzhen, Guangdong, China Email: support@anceltech.com Website: www.anceltech.com...
  • Page 2 2.Always keep this manual handy since it contains important information about using the product. Note: Due to the fact that the ANCEL Diagnostic Smoke Leak Detector product line consists of a series of product models, which vary from one model to another, not all of the descriptions in this manual are applicable to all product models. Please refer to the specific product configuration for the applicability of the introduction.
  • Page 3: Scope Of Use

    Scope of use The smoke leak detector, with its WYSIWYG efficiency, is widely applicable to the leak test of various pipeline systems and quick pinpoint leak position. This product can effectively find the leakage position by simulating most suitable operating pressure condition of the vehicle pipeline, and introducing the smoke into the vehicle pipeline system through appropriate adapters.
  • Page 4 (U.S. Standard) certain models Mostly used when work on leak test on Configured for Block-cap set vehicle engine while it’s unmounted certain models from the vehicle. S100 S100 Pro S110 S110 Pro S160 Output Pressure 0.5psi 0.5psi 0.5psi 0.5psi 0.8-1.2bar...
  • Page 5 S1000 S200 S2000 S300 S300 Lite Output Pressure 0.8-1.2bar 0.8-1.2bar 0.8-1.2bar 0.8-1.2bar 0.8-1.2bar inbuild air inbuild air inbuild air inbuild air inbuild air Air Source compressor compressor compressor compressor compressor Function Smart PCA Inbuilt √ √ Flow Meter √ √ Mechanical Pressure Gauge √...
  • Page 6: Specification

    ∅ Adapter Cone 25-85cm √ √ √ √ ∅ Adapter Cone Set 17-55mm √ √ Configuration 23pcs Blockoff Cap Set √ √ √ EVAP Test Kit √ √ Smoke Diffuser √ √ √ √ Specification Power Supply 12V(Automotive Battery)/5Amp Output Pressure 0.5psi or 0.8-1.2bar(Please refer to the specific product configuration) Flow Rate <6LPM or <8LPM(Please refer to the specific product configuration)
  • Page 7 Configured for While set up the unit, the Smoke Delivery Hose Smoke Outlet Port all models need to be mounted onto the Smoke Outlet . Configured for While set up the unit, the power cords need to Power Socket all models plug into the power socket.
  • Page 8 In many cases excessive smoke exiting a leak may make it difficult to determine the exact location of the leak. The purpose of the Flow Control Valve is to decrease the amount of smoke exiting a leak so that Configured for its position may be pinpointed without the masking Flow Dial certain models...
  • Page 9 No Leak Small Leak Massive Leak Flow Meter drop to Flow Meter stay between Flow Meter raise and ‘0’ and pressure reading 0.1 to 0.5LPM. pressure reading drop to ‘0’. raise to Max. Generic Operation 1.Mount the hook on to the unit. 2.Mount the shop air adapter to the unit (For the model without built-in air pump inside).
  • Page 10 vehicle. To access this port for testing, remove the cap, then remove the Schrader Valve from inside the Service Port, using the supplied Schrader Valve Removal Tool. Important Note: The Schrader Valve has left-hand threads, turn clockwise to remove! Connect the supplied Service Port Adaptor to the Service Port. 4.The Onboard Diagnostics on vehicles 1996 and beyond will determine if a leak exists, the following trouble codes may be indicated to report the leak: P0442 for a .040 leak standard...
  • Page 11: Troubleshooting

    Troubleshooting Error Possible Reason Solution Mistaken possitive to negative Connect to power source correctly. Check with meter if the power line LED not ON Poor contact of power line is broken , confirm and replace the power lines. Flow Dial not open Open the Flow Dial anti-clockwise.

Table of Contents

Save PDF