Installation Instruction GENERAL INSTRUCTIONS: - This product must be installed by a licensed plumber. Ensure that your plumbing installation conforms to the Australian/New Zealand Standard AS/NZS 3500. - All pipework must be thoroughly flushed prior to the installation of the mixer. In-line filters must be fitted on both hot and cold supplies to prevent foreign particles from damaging the ceramic cartridge.
Page 3
NOTE: To install the mixer, the floor thickness must be at least 50mm. If it is insufficient, the floor should be raised by at least 30mm before installation. 1. Mark the points according to the dimensions. 2. Drill holes in the floor oat the marked points, ensuring the distance from the bathtub to the concealed box is correct.
Page 4
Leveling Plate Spirit Level Testing Plugs 5. Protect the concealed box while filling the 6. Remove the screws and leveling plate, take floor around it. out the spirit level and test plugs. 7. Slide the decorative cover onto the straight 8.
9. Use an H3 Allen Key to tighten the screws 10. Insert the inlet pipe into the corresponding through the straight pipe, connecting the fixed hole of the concealed box, adjust the position pipe and the straight pipe. of the spout outlet and the bathtub, and secure them with the concealed box.
Need help?
Do you have a question about the Zen SS316L and is the answer not in the manual?
Questions and answers