  • Page 1 KEEP IN VEHICLE READ OPERATING INSTRUCTIONS INSIDE BEFORE OPERATING OESP 3016/3017 OPEN & CLOSED SYSTEMS AUGER, SPINNER, AND LIQUID (PRE-WET) OPERATION AND CONFIGURATION MANUAL...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Features and Description ..........................4 Specifications ..............................4 Spreader System Components ........................5-6 Relief Valve Adjustment ..........................7 OMNI-System ESP P/N Breakdown ......................8 ® Complete Spreader Packages ........................ 9-10 Wire Harnesses ............................11 Pin-Outs ...............................12 Pre-Wet Exhaust Valve Diagram ........................13 Spreader System Components ........................14 Controls and Displays ..........................15 Operation Instructions ..........................16 Configuration Menu ..........................
  • Page 4: Features And Description

    FEATURES AND DESCRIPTION • Auto and Manual Operation • 9 levels of Auger Control • 9 levels of Spinner Control • 9 levels of Pre-Wet Control • Blast Mode • Pause Mode • Liquid/Pre-Wet (Electric or Hydraulic Motor) • Ground Speed Controls •...
  • Page 5: Spreader System Components

    SPREADER SYSTEM COMPONENTS Controller Wire Harness — 34T42521 (Sold Separately) Spreader Controller — OESP OESP300A Valve Enclosure Wire Harness — 34T42522 (Sold Separately) Spinner Auger Spreader Manifold — HF80983-12 (Sold Separately)
  • Page 6 SPREADER SYSTEM COMPONENTS Auger Spinner Spreader Manifold — HF136735-19 (Sold Separately) Spinner Spinner Auger Auger Liquid Liquid Spreader Manifold — HF172326-23 (Includes Hydraulic Liquid/Pre-Wet) (Sold Separately)
  • Page 7: Relief Valve Adjustment

    RELIEF VALVE ADJUSTMENT Main System Relief (Factory Setting 1,800 PSI) 1. The tools required for adjusting the main relief setting includes: ¾" wrench and a ¼" Allen drive. 2. Tee a pressure gauge into the pump port (gauge greater than 3,000 PSI). 3.
  • Page 8: Omni-System ® Esp P/N Breakdown

    OMNI ELECTRONIC SPREADER PACKAGE OESP 30 16 G 3 ASM SS Series OESP — Omni ESP Controller 30 — OESP300A Valve Configuration 16 — Open Center (Gear Pump) 17 — Closed Center (LS Piston Pump) Hydraulic Functionality G — Auger + Spinner H —...
  • Page 9: Complete Spreader Packages

    COMPLETE SPREADER PACKAGES NO ENCLOSURE OESP3016G (Open Center) OESP3017G (Closed Center) Includes the following: Includes the following: • OESP300A – Controller • OESP300A – Controller • 34T42521 – Controller Wire Harness • 34T42521 – Controller Wire Harness • 34T42522 – Valve Enclosure Harness •...
  • Page 10 COMPLETE SPREADER PACKAGES WITH ENCLOSURE OESP3016GASM (Open Center) OESP3017GASM (Closed Center) Includes the following: Includes the following: • OESP300A – Controller • OESP300A – Controller • 34T42521 – Controller Wire Harness • 34T42521 – Controller Wire Harness • 34T42522 – Valve Enclosure Harness •...
  • Page 11: Wire Harnesses

    WIRE HARNESS LOCATION/ASSIGNMENT Controller Wire Harness — 34T42521 To Ground Speed To Controller To Spinner & Auger Valve Enclosure To Liquid Valve Enclosure Wire Harness — 34T42522 To Auger Orange Black To Controller Harness Black White To Spinner...
  • Page 12: Pin-Outs

    PIN-OUTS Controller Wire Harness — 34T42521 To Ground Speed To Controller To Spinner & Auger Valve Enclosure PIN LOCATION WIRE COLOR WIRE LABEL Pink Ground Speed Black Ground To Liquid +12 Volts +12 Volts +12 Volts White Spinner Orange Auger Green Liquid Green...
  • Page 13: Pre-Wet Exhaust Valve Diagram

    PRE-WET EXHAUST VALVE DIAGRAM Parts Needed: Qty. (1) NXPV7630AM12TN12ER This is a solenoid operated proportional flow control valve used to direct flow to the Pre-Wet Motor from the Auger Return. It electronically regulates the Auger Return flow between the Pre-Wet Motor and Tank. Max.
  • Page 14: Spreader System Components

    SPREADER SYSTEM COMPONENTS Liquid (Pre-Wet) Kits Developed to match the granular ground speed spreading consistently to maintain the desired gallons per ton of salt distribution. Our pre-wet kits are mounted and pre-wired into NEMA enclosures. Pumps are available for 5 or 6 GPM in electric systems or 10 to 20 GPM in hydraulic systems. Electric Liquid (Pre-Wet) Hydraulic Liquid (Pre-Wet)
  • Page 15: Controls And Displays

    CONTROLS AND DISPLAYS Liquid (Pre-Wet) Display Auger Display Spinner Display Auto Light Spinner Rate Control Auger Rate Control Liquid (Pre-Wet) Rate Control Pause On / Off Blast OPERATION INSTRUCTIONS – CONTROLS ON-OFF: Press the On – Off button to power controller AUGER RATE CONTROL: Rotate the ‘Auger’...
  • Page 16: Operation Instructions

    OPERATION INSTRUCTIONS AUTO MODE OPERATION In Auto Mode the truck speed (MPH) is used to automatically increase/decrease the auger output to maintain constant rate. If the Auto Mode feature is going to be used, the vehicle speed will need to be synchronized with the controller. See steps below on how to verify the controller is receiving the speedometer signal and how to sync.
  • Page 17: Configuration Menu

    CONFIGURATION MENU ACCESSING CONFIGURATION MENU: This menu is passcode protected to limit access to non-authorized personnel. It is recommended to change the passcode from the default value to limit access and prevent unintentional system adjustments. Follow the steps below to enter the Configuration Menu: 1.
  • Page 18 CONFIGURATION MENU SYSTEM MENU: Firmware Bundle: Non-adjustable and reference only. Profile: Non-adjustable and reference only. Passcode Change: Using the Liquid and Spinner knobs, adjust the default passcode. EQUIPMENT MENU: E Flow: Flow Sharing – N/A on standard Omni System ESP (OESP) only setups.
  • Page 19 CONFIGURATION MENU Plow Down Float: N/A on standard Omni System ESP (OESP) only setups. SPREADER: 0–OFF / 1-ON Retain: Use the Spinner knob to toggle the retain settings feature. This functionality allows the controller to retain the Auger, Liquid, and Spinner rates through power cycles.
  • Page 20 CONFIGURATION MENU SECONDS BLAST Time: The Blast duration can be adjusted from 0 – 199 seconds. Use the Liquid and Spinner knob to change. Above 199 setting will change to LT (latching). This means when you hit Blast, it will stay on until turned off. SECONDS Take-off Timer: The take-off timer is only applicable to Auto Mode, and it is intended...
  • Page 21: Troubleshooting

    TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE OESP300A controller will not Check wiring designation, and check inline fuse power on if installed. Auger - Non-Functional Check if the AUTO display light is illuminated yellow on controller. The Auger will not function in Auto Mode until vehicle begins moving.
  • Page 22: Notes

    NOTES...
  • Page 23 NOTES...
  • Page 24 201 East Jackson Street, Muncie, Indiana 47305 800-367-7867 Fax: 765-284-6991 info@munciepower.com • • Specifications are subject to change without notice. Visit www.munciepower.com for warranties and literature. All rights reserved. © Muncie Power Products, Inc. (2024) A Member of the Interpump Group IN24-01 (Rev. 05-24)