    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com CONTENT 1. General ..................................3 1.1 Introduction ................................3 1.2 Information regarding the user manual ....................3 1.3 Warranty................................. 3 2. Warnings ................................4 3. Principle and use of the product ........................ 5 4. Pre-installation inspections ..........................5 5.
  • Page 3: General

    1. General 1.1 Introduction The level gauge manufactured by WISE Control Inc. is installed outside of vessel or tank which has containing fluid. Fluid enter to level gauge attached outside of vessel or tank, and the level of the fluid stored inside the vessel or tank is checked.
  • Page 4: Warnings

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 2. Warnings Handling manual for safe use To ensure safe and proper use of the product, please thoroughly read this manual before use. Improper handling may cause equipment malfunction, as well as accidents such as injury. Warnings !...
  • Page 5: Principle And Use Of The Product

    3. Principle and use of the product The glass type level gauge manufactured by WISE Control Inc. is used to check the level of fluid in a vessel or tank by allowing fluid inside the vessel or tank to enter the level gauge.
  • Page 6: Precautions For Installation And Operation Of The Product

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 5. Precautions for installation and operation of the product 5-1. Pre-operation checks (Warming up) 1) Warm up for approximately 80 minutes until the temperature and pressure of the installed level gauge match the temperature and pressure of the tank or other vessel where the level gauge has been installed.
  • Page 7: Option_Illuminator

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 5-2. Option_Illuminator If the Illuminator has attached to the level Gauge, check the below precautions for installing the insulation. Check the operating temperature in the drawing or data sheet, and if the operating temperature is over 80 ℃, install the insulation only up to same height as the body so that the insulation does not cover the illuminator.
  • Page 8: Troubleshooting

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 5-3. Troubleshooting If the level of fluid is not visible through the glass cover of the level gauge even after the level gauge has been installed, please check the following. 1) Confirm that the block valve on the vessel and the gauge valve of the level gauge are open. (The fluid will not enter the gauge is the block valve and gauge valve are closed.) 2) When installing and operating, check if rapid ingress of fluid has triggered the check ball.
  • Page 9: Maintenance And Repair

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 6. Maintenance and repair 6-1. Basic matters The glass and gasket of the level gauge are consumables and must be replaced regulalry. (Depending on operating conditions, replacement is required every 1 to 2 months, or up to 6 months.
  • Page 10: Reassembling The Cover

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 6-3. Reassembling the cover 1) Assemble the gasket, glass and cover in the order shown in the figure below. (See <Figure 2>) <Figure 2> 2) Fasten the bolt and nut manually, without using tools. 3) Using a torque wrench, fasten the bolt and nut in three increments from 200 kgf·cm (20 N·m) to 400 kgf·cm (40 N·m) First increment : 200 kgf·cm (20 N·m) Second increment : 300 kgf·cm (30 N·m)
  • Page 11: Transport, Packaging And Storage Of The Product

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 7. Transport, packaging and storage of the product 1) The product must not be exposed to humidity, dust or other contaminants. 2) The product must not be subjected to impact during storage. 3) When returning the product for repairs, safely package the product in its original packaging, and return the related documentation as well.
  • Page 12 The specifications and appearance of this product are subject to change without notice for quality improvement, and WISE reserves the right to change this. The illustrations use in this instruction manual are for illustrative purposes only and may differ from the actual product.
  • Page 13 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Glass type level gauge L100 & L200 C-QIM-2731-F06_KR_Rev.2...
  • Page 14 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 목차 1. 일반사항 ................................... 2 1.1 소개 ..................................2 1.2 사용설명서 관련 정보 ............................2 1.3 보증 ..................................2 2. 경고 .................................... 3 3. 제품 원리 및 용도 ............................... 4 4. 제품 설치 전 점검 사항 ............................ 4 5.
  • Page 15: 일반사항

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 1. 일반사항 1.1 소개 ㈜와이즈에서 제작하는 레벨 게이지(Level gauge)는 유체가 저장된 탱크 등의 용기 외부에 설치하여, 탱크 등 용기 외부에 부착된 레벨 게이지 내부로 유체를 유입시켜 탱크 등의 용기 내부에 저장된 유체 의 수위를 확인하는 제품입니다. 레벨...
  • Page 16 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 2. 경고 안전한 사용을 위한 취급 설명서 이 제품을 바르고 안전하게 사용하기 위하여 사용 전에 이 취급설명서를 잘 읽어주시기 바랍니다. 취급 시의 오류는 기기 고장의 원인이 되며, 상해나 사고 등의 재해가 발생할 수 있습니다. 경 고 !...
  • Page 17: 제품 원리 및 용도

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 3. 제품 원리 및 용도 ㈜와이즈 에서 공급하는 글라스 타입 레벨 게이지는 탱크 등의 용기 내부의 액체를 레벨 게이지 내부로 유입시켜 탱크 등의 용기의 수위를 확인하는 제품입니다. 액체가 레벨 게이지 내부로 유입되면 레벨 게이지 커버의 유리를 통해 탱크 등 용기의 수위를 확인할 수...
  • Page 18: 문제 발생 시 확인사항

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 5-2. 문제 발생 시 확인사항 레벨 게이지 설치 및 작동 이후에도 레벨 게이지 커버의 유리를 통해 유체 수위를 확인할 수 없는 경우 다음 사항을 확인하여 주십시오. 1) 탱크 등 용기의 블록 밸브 와 레벨 게이지의 게이지 밸브가 열린 상태인지 확인하여 주십시오. (블록...
  • Page 19: 유지보수

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 6. 유지보수 6-1. 기본 사항 레벨 게이지의 유리,가스켓 등 은 소모품 이므로 주기적으로 교체 해야 합니다. (운전 조건에 따라 1~2 개월 또는 6개월 마다 교체가 필요하며, 최소 6개월마다 교체를 권장합니다.) 유리 및 가스켓 등 소모품 교체 및 레벨 게이지의 내부 세척이 필요한 경우에는 다음의 6.2 항에 따라 레벨...
  • Page 20: 커버 재 조립 방법

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 6-3. 커버 재 조립 방법 1) 아래 그림과 같이 가스켓, 유리, 커버를 순서대로 결합하여 주십시오. (<Figure 1 > 참조) <Figure 1.> 2) 공구를 사용하지 않은 채로, 볼트, 너트를 먼저 조여 주십시오. 3) 토크 렌치를 사용하여 200 kgf·cm (20 N·m) 에서 ~ 400 kgf·cm (40 N·m) 까지 총 3 단계에 걸쳐 볼트, 너트를...
  • Page 21: 제품의 운송 및 포장, 보관

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 7. 제품의 운송 및 포장, 보관 1) 제품은 습기, 먼지 및 기타 오염 물질에 노출되지 않아야 합니다. 2) 제품은 충격에 노출되지 않도록 보관되어야 합니다. 3) 수리를 위한 반품의 경우 원래의 포장 상태로 안전하게 포장하고 관련 서류도 함께 반환해야 합니다. 4) 운송...
  • Page 22 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 본 설명서의 내용은 심혈을 기울여 제작되었지만, 오탈자 또는 수정해야 할 내용이 있을 수 있으니 이점 양해하여 주시기 바랍니다. 본 제 품의 규격 및 외관은 품질 향상을 위해 사전 통보 없이 변경될 수 있으며, ㈜와이즈는 이에 대한 변경 권리를 가집니다. 본 사용설명서에서 사용하는...

This manual is also suitable for:

L200

Table of Contents