  • Page 1 Moisture meter Operating manual humimeter M30 Universal Material Moisture Meter for water content determination of special materials 78,0 °F | 6,16 % | 456 kg/m | -27,3 td | 0,64 aw | 51,9 %r.H. | 14,8 % abs | 100,4 g/m...
  • Page 2: Your Humimeter M30 At A Glance

    Operating manual humimeter M30 Your humimeter M30 at a glance The main unit Name USB Port (optional) Display Keypad Rubber protection cover Page 2...
  • Page 3: Rear Of The Main Unit

    Rear of the main unit Name Sensor surface Battery compartment The display Name Product type Water content in % ("6.1 How moisture is defined") Display symbols Temperature display Page 3...
  • Page 4: The Display Symbols

    Operating manual humimeter M30 The display symbols Symbol Name Symbol Name Enter Change input level Down Back Change menu Enter numbers Enter data Enter letters View measurements Continue / go right Delete measurements Left On/off button, display light Save measured value...
  • Page 5 Data Log menu Name Change menu Display illumination / device on/off Save measured value Show the last recorded values Main menu The main menu comprises the following menu items: • Edit Logs: Manual Logs, Clear Logs • Print Logs: Last Log, All Logs, Clear Logs •...
  • Page 6: Table Of Contents

    Operating manual humimeter M30 Inhaltsverzeichnis Your humimeter M30 at a glance ������������������������������������������������ 2 The main unit ......................2 Rear of the main unit ....................3 The display ....................... 3 The display symbols ....................4 The menues ......................4 1� Introduction �������������������������������������������������������������������� 9 Information about this operating manual ..........
  • Page 7 Preparing a measurement ..............15 Taking a measurement ................15 Simplified user ..................16 5.3.1 Activating/Deactivating the simplified user ..........16 5.3.2 Using the simplified user ............... 16 Hold function - Freezing the displayed values ........16 5.4.1 Activating the Hold function in the options menu ......... 17 5.4.2 Using the Hold function ................
  • Page 8 Operating manual humimeter M30 Selecting °C/°F ..................32 Changing the Userlevel ................. 33 9.7.1 Changing from the advanced to the simplified user ......33 9.7.2 Changing from the simplified user to the advanced user ....... 33 Reducing the device's power consumption ..........34 9.8.1...
  • Page 9: Introduction

    Introduction Information about this operating manual This operating manual is designed to enable you to use the humimeter M30 safely and effectively. It is part of the device, has to be stored nearby and must be easily accessible to users at all times.
  • Page 10: Symbols Used In This Manual

    Operating manual humimeter M30 Symbols used in this manual All of the safety information provided in this manual is shown with a corresponding symbol. ATTENTION It is essential to observe this warning. Non-compliance can lead to damage to property or equipment.
  • Page 11: For Your Safety

    For your safety The device complies with the following European directives: • Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS) • Electromagnetic compatibility (EMC) The device corresponds to state-of-the-art technology. However, it is still associated with a number of residual hazards. These hazards can be avoided through strict observance of our safety information Proper use •...
  • Page 12: General Safety Information

    Operating manual humimeter M30 General safety information The following safety information has to be observed at all times to avoid damage to objects and injury to people: • Remove the batteries if the device isn't used for a prolonged period of time (4 weeks).
  • Page 13: Inserting Batteries

    • humimeter USB data interface module - USB flash drive with software and USB- cable or download using humimeter.com/software • Operating manual Optional accessories: • humimeter USB data interface module - USB stick with LogMemorizer software (measurement data acquisition and evaluation software) and USB cable •...
  • Page 14: Using The Device - Basics

    Operating manual humimeter M30 Using the device - Basics Switching the device on • Press the  button for 3 seconds. » The display will then show the status indicator (figure 6). » After inserting the batteries, the device switches on automatically.
  • Page 15: Measuring Process

    Measuring process Preparing a measurement To do so: The device has to have nearly the same temperature than the product being measured. It is recommended to let your humimeter device adjust to the surrounding temperature of the product before the measurement.
  • Page 16: Simplified User

    Operating manual humimeter M30 Information - Measuring accuracy This rapid and non-destructive measuring procedure allows you to quickly take moisture readings at a number of different points. When saving the individual readings, the device will automatically calculate the readings’ average (see "5.6...
  • Page 17: Activating The Hold Function In The Options Menu

    5.4.1 Activating the Hold function in the options menu To do so: The device has to be switched on and be in the product selection menu. Press twice or hold for 2 seconds. Select Options. To do so, press and con- firm by pressing Select Log Time (figure 14).
  • Page 18: Activating The Manual Saving Function In The Options Menu

    Operating manual humimeter M30 5.5.1 Activating the manual saving function in the options menu To do so: The device has to be switched on and be in the product selection menu. Press twice or hold for 2 seconds. Select Options. To do so, press...
  • Page 19: Using The Manual Saving Function

    5.5.2 Using the manual saving function To do so: The device has to be in the Data Log menu. The device is set to Data Log Time - Manual. Press » The display will now appear as shown in figure and the disc symbol will be preceded by the digit one.
  • Page 20: Saving Several Readings (A Measurement Series) At The Same Time

    Operating manual humimeter M30 Saving several readings (a measurement series) at the same time To do so: The device has to be in the Data Log menu. Take several readings (see "5. Measuring process"). To save a reading, press as soon as the reading has been taken.
  • Page 21: Viewing Individual Readings

    Name Name of the measurement series Temperature (average) Date & start time of the measurement series Date & end time of the measurement series Number of saved readings Product type Device name Water content (average) Viewing individual readings To do so: You must have saved a reading (e.g.
  • Page 22: Viewing Individual Readings From A Series Of Measurements

    Operating manual humimeter M30 Viewing individual readings from a series of measurements To do so: You must have saved a series of measurements (e.g. 2 logs). The display will now appear as shown in figure 28. Press Navigate to the required measurement series. To do so, press »...
  • Page 23: Deleting Individual Measurement Series

    Press to leave the Edit Logs menu. Press to leave the main menu. 5.10 Deleting individual measurement series To do so: You must have saved a measured value (e.g. 1 log) or a series of measure- ments (e.g. 3 logs). The display will now appear as shown in figure 35. Press »...
  • Page 24: Deleting Individual Values From A Single Series Of Measurements

    Operating manual humimeter M30 5.11 Deleting individual values from a single series of measurements To do so: You must have saved a series of measurements comprising at least 2 logs. The display will now appear as shown in figure 39.
  • Page 25: Product Types

    The humimeter M30 is equipped with 11 freely editable characteristic curves, as well as a digital characteristic curve and a reference characteristic curve. It is possible for the user to edit these free characteristic curves on the humimeter M30 and set the parame- ters of the material to be measured.
  • Page 26: Using The Logmemorizer Program

    Operating manual humimeter M30 Using the LogMemorizer program To do so: The device is provided with USB interface, and the USB stick with LogMemo- rizer software and USB cable are available. Otherwise, you can also install the software at humimeter.com/software or by scanning the QR code.
  • Page 27: Exporting Measured Values To A Computer

    The LogMemorizer program is installed. You must have taken and saved one or several moisture readings. Options: You can export moisture readings from the humimeter M30 or initiate the export at your computer. Exporting moisture readings from the humimeter M30...
  • Page 28: Checking The Device's Status

    Operating manual humimeter M30 Switch on the humimeter M30. Open the Communication tab in LogMemorizer (figure 51) .Select and click on one of the two buttons shown in figure 52. » Import all manual logs (for importing all manually saved readings) »...
  • Page 29: Configuring The Device

    » The display will show the following information: Name Serial number Software version Battery status Memory status Confirm by presssing Press  to leave the main menu. Configuring the device Turning on Bluetooth The information on Bluetooth is provided in a separate operating manual. Page 29...
  • Page 30: Adjust The Date/Time

    Operating manual humimeter M30 Adjust the date/time Press  twice or hold for 2 seconds. Select Options. To do so, press and confirm by pressing Select Date/Time. To do so, press and confirm by pressing » The display will now appear as shown in figure 53.
  • Page 31: Selecting A Language

    Selecting a language Press twice or hold for 2 seconds. Select Options. To do so, press and confirm by pressing Select Language. To do so, press and confirm by pressing Navigate to the required language. To do so, press and confirm by pressing »...
  • Page 32: Deactivating Options

    Operating manual humimeter M30 Confirm the four-digit password by pressing » The setting has been saved. » The °C/°F, Adjust, Userlevel, BL On Time, Auto Off Time, Materialcalibration, Pass- word, Reset options are now activated. Press to leave the Options menu.
  • Page 33: Changing The Userlevel

    Changing the Userlevel 9.7.1 Changing from the advanced to the simplified user To do so: All of the options must be activated (see "9.4 Activating options"). Press twice or hold for 2 seconds. Select Options. To do so, press and confirm by pressing Select Userlevel.
  • Page 34: Reducing The Device's Power Consumption

    Operating manual humimeter M30 Reducing the device's power consumption 9.8.1 Configuring the display illumination time To do so: All of the options must be activated (see "9.4 Activating options"). Press twice or hold for 2 seconds. Select Options. To do so, press and confirm by pressing Select BL On Time.
  • Page 35: Configuring The Material Calibration Function

    Configuring the material calibration function The type calibration function is described in a separate operating manual. 9.10 Changing the password To do so: All of the options must be activated (see "9.4 Activating options"). Press twice or hold for 2 seconds. Select Options.
  • Page 36: Resetting The Device To Its Factory Settings

    Operating manual humimeter M30 9.11 Resetting the device to its factory settings To do so: All of the options must be activated (see "9.4 Activating options"). Press twice or hold for 2 seconds. Select Options. To do so, press and confirm by pressing Select Reset.
  • Page 37: Checking The Calibration

    10.2 Checking the calibration The calibration of the device should be checked every four weeks. Use the optionally purchasable test plate for checking. To do so: The device and the test plate must have a temperature between 20.0 °C and 26.0 °C. The wooden cassette must lie on a wooden table.
  • Page 38: Configuring The Material Calibration Function

    Operating manual humimeter M30 10.3 Configuring the material calibration function To do so: The device must have a temperature between 20.0 °C and 26.0 °C. Switch on the device. Press twice or hold for two seconds to enter the main menu level.
  • Page 39: Care Instructions

    10.4 Care instructions • Do not leave the device out in the rain. The device is not waterproof. • Do not expose the device to extreme temperatures. • Protect the device from strong mechanical shocks and loads. 10.5 Cleaning the device ATTENTION Do not clean with fluids Water or cleaning fluid getting inside the device can destroy the device.
  • Page 40 Operating manual humimeter M30 Fault Cause Remedy Material thickness not Make sure that the minimum sufficient material thickness of 30 mm is given. Incorrect contact pressure Press the device against the material being measured with a pressure of approx. 4 kg.
  • Page 41: Storage And Disposal

    12. Storage and disposal 12.1 Storing the device The device must be stored as follows: • Do not store outdoors. • Store in a dry and dust-free place. • Protect the device from sunlight. • Avoid mechanical shocks/loads. • Remove the batteries if the device isn't used for a period of 4 weeks or longer •...
  • Page 42: Device Information

    Operating manual humimeter M30 13. Device information 13.1 CE declaration of conformity _______________ KONFORMITÄTSERKLÄRUNG DECLARATION OF CONFORMITY Name/ Adresse des Herstellers: Schaller Messtechnik GmbH Max-Schaller-Straße 99 Name/ address of manufacturer: A – 8181 St. Ruprecht Produktbezeichnung: humimeter Product designation: Typenbezeichnung: GE1 ;...
  • Page 43 Für das angeführte Produkt ist eine vollständige Dokumentation mit Betriebsanleitung in Originalfassung vorhanden. For the mentioned product a complete documentation with manual of instruction in original version is available. Bei Änderungen, die nicht vom Hersteller spezifiziert sind, verliert diese Konformitätserklärung die Gültigkeit.
  • Page 44 Operating manual humimeter M30 _______________ DECLARATION OF CONFORMITY Schaller Messtechnik GmbH Name/ address of manufacturer: Max-Schaller-Straße 99 A – 8181 St. Ruprecht Product designation: humimeter Type designation: GE1 ; GF2 ; LM5 ; LM6 ; M05 ; M20 ; M30 ; M50...
  • Page 45 For the mentioned product, a complete documentation with manual of instruction in original version is available. In case of any changes not agreed upon with the manufacturer, this declaration of conformity loses its validity. St. Ruprecht a.d. Raab, 31.07.2022 …............Bernhard Maunz Legal binding signature of the issuer Page 45...
  • Page 46: Technical Data

    Operating manual humimeter M30 13.2 Technical data Display resolution 0.1 % wood moisture, 0.5 °C/°F temperature Measuring range Dependents on material Operating temperature 0 °C bis +40 °C Storage temperature -20 °C bis +60 °C Temperature compensation Automatic Data memory up to 10.000 measured values...
  • Page 47: Notes

    14. Notes Page 47...
  • Page 48 Food Buildings Bioenergy Paper / Board Schaller Messtechnik develops, produces and sells professional moisture meters and turnkey solutions.. Schaller Messtechnik GmbH Max-Schaller-Straße 99, A - 8181 St. Ruprecht an der Raab Tel +43 (0)3178 - 28899 , Fax +43 (0)3178 - 28899 - 901...