Rear of the main unit Name Sensor surface Battery compartment The display Name Product type Water content in % ("6.1 How moisture is defined") Display symbols Temperature display Page 3...
Operating manual humimeter M30 The display symbols Symbol Name Symbol Name Enter Change input level Down Back Change menu Enter numbers Enter data Enter letters View measurements Continue / go right Delete measurements Left On/off button, display light Save measured value...
Page 5
Data Log menu Name Change menu Display illumination / device on/off Save measured value Show the last recorded values Main menu The main menu comprises the following menu items: • Edit Logs: Manual Logs, Clear Logs • Print Logs: Last Log, All Logs, Clear Logs •...
Operating manual humimeter M30 Inhaltsverzeichnis Your humimeter M30 at a glance ������������������������������������������������ 2 The main unit ......................2 Rear of the main unit ....................3 The display ....................... 3 The display symbols ....................4 The menues ......................4 1� Introduction �������������������������������������������������������������������� 9 Information about this operating manual ..........
Page 7
Preparing a measurement ..............15 Taking a measurement ................15 Simplified user ..................16 5.3.1 Activating/Deactivating the simplified user ..........16 5.3.2 Using the simplified user ............... 16 Hold function - Freezing the displayed values ........16 5.4.1 Activating the Hold function in the options menu ......... 17 5.4.2 Using the Hold function ................
Page 8
Operating manual humimeter M30 Selecting °C/°F ..................32 Changing the Userlevel ................. 33 9.7.1 Changing from the advanced to the simplified user ......33 9.7.2 Changing from the simplified user to the advanced user ....... 33 Reducing the device's power consumption ..........34 9.8.1...
Introduction Information about this operating manual This operating manual is designed to enable you to use the humimeter M30 safely and effectively. It is part of the device, has to be stored nearby and must be easily accessible to users at all times.
Operating manual humimeter M30 Symbols used in this manual All of the safety information provided in this manual is shown with a corresponding symbol. ATTENTION It is essential to observe this warning. Non-compliance can lead to damage to property or equipment.
For your safety The device complies with the following European directives: • Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS) • Electromagnetic compatibility (EMC) The device corresponds to state-of-the-art technology. However, it is still associated with a number of residual hazards. These hazards can be avoided through strict observance of our safety information Proper use •...
Operating manual humimeter M30 General safety information The following safety information has to be observed at all times to avoid damage to objects and injury to people: • Remove the batteries if the device isn't used for a prolonged period of time (4 weeks).
• humimeter USB data interface module - USB flash drive with software and USB- cable or download using humimeter.com/software • Operating manual Optional accessories: • humimeter USB data interface module - USB stick with LogMemorizer software (measurement data acquisition and evaluation software) and USB cable •...
Operating manual humimeter M30 Using the device - Basics Switching the device on • Press the button for 3 seconds. » The display will then show the status indicator (figure 6). » After inserting the batteries, the device switches on automatically.
Measuring process Preparing a measurement To do so: The device has to have nearly the same temperature than the product being measured. It is recommended to let your humimeter device adjust to the surrounding temperature of the product before the measurement.
Operating manual humimeter M30 Information - Measuring accuracy This rapid and non-destructive measuring procedure allows you to quickly take moisture readings at a number of different points. When saving the individual readings, the device will automatically calculate the readings’ average (see "5.6...
5.4.1 Activating the Hold function in the options menu To do so: The device has to be switched on and be in the product selection menu. Press twice or hold for 2 seconds. Select Options. To do so, press and con- firm by pressing Select Log Time (figure 14).
Operating manual humimeter M30 5.5.1 Activating the manual saving function in the options menu To do so: The device has to be switched on and be in the product selection menu. Press twice or hold for 2 seconds. Select Options. To do so, press...
5.5.2 Using the manual saving function To do so: The device has to be in the Data Log menu. The device is set to Data Log Time - Manual. Press » The display will now appear as shown in figure and the disc symbol will be preceded by the digit one.
Operating manual humimeter M30 Saving several readings (a measurement series) at the same time To do so: The device has to be in the Data Log menu. Take several readings (see "5. Measuring process"). To save a reading, press as soon as the reading has been taken.
Name Name of the measurement series Temperature (average) Date & start time of the measurement series Date & end time of the measurement series Number of saved readings Product type Device name Water content (average) Viewing individual readings To do so: You must have saved a reading (e.g.
Operating manual humimeter M30 Viewing individual readings from a series of measurements To do so: You must have saved a series of measurements (e.g. 2 logs). The display will now appear as shown in figure 28. Press Navigate to the required measurement series. To do so, press »...
Press to leave the Edit Logs menu. Press to leave the main menu. 5.10 Deleting individual measurement series To do so: You must have saved a measured value (e.g. 1 log) or a series of measure- ments (e.g. 3 logs). The display will now appear as shown in figure 35. Press »...
Operating manual humimeter M30 5.11 Deleting individual values from a single series of measurements To do so: You must have saved a series of measurements comprising at least 2 logs. The display will now appear as shown in figure 39.
The humimeter M30 is equipped with 11 freely editable characteristic curves, as well as a digital characteristic curve and a reference characteristic curve. It is possible for the user to edit these free characteristic curves on the humimeter M30 and set the parame- ters of the material to be measured.
Operating manual humimeter M30 Using the LogMemorizer program To do so: The device is provided with USB interface, and the USB stick with LogMemo- rizer software and USB cable are available. Otherwise, you can also install the software at humimeter.com/software or by scanning the QR code.
The LogMemorizer program is installed. You must have taken and saved one or several moisture readings. Options: You can export moisture readings from the humimeter M30 or initiate the export at your computer. Exporting moisture readings from the humimeter M30...
Operating manual humimeter M30 Switch on the humimeter M30. Open the Communication tab in LogMemorizer (figure 51) .Select and click on one of the two buttons shown in figure 52. » Import all manual logs (for importing all manually saved readings) »...
» The display will show the following information: Name Serial number Software version Battery status Memory status Confirm by presssing Press to leave the main menu. Configuring the device Turning on Bluetooth The information on Bluetooth is provided in a separate operating manual. Page 29...
Operating manual humimeter M30 Adjust the date/time Press twice or hold for 2 seconds. Select Options. To do so, press and confirm by pressing Select Date/Time. To do so, press and confirm by pressing » The display will now appear as shown in figure 53.
Selecting a language Press twice or hold for 2 seconds. Select Options. To do so, press and confirm by pressing Select Language. To do so, press and confirm by pressing Navigate to the required language. To do so, press and confirm by pressing »...
Operating manual humimeter M30 Confirm the four-digit password by pressing » The setting has been saved. » The °C/°F, Adjust, Userlevel, BL On Time, Auto Off Time, Materialcalibration, Pass- word, Reset options are now activated. Press to leave the Options menu.
Changing the Userlevel 9.7.1 Changing from the advanced to the simplified user To do so: All of the options must be activated (see "9.4 Activating options"). Press twice or hold for 2 seconds. Select Options. To do so, press and confirm by pressing Select Userlevel.
Operating manual humimeter M30 Reducing the device's power consumption 9.8.1 Configuring the display illumination time To do so: All of the options must be activated (see "9.4 Activating options"). Press twice or hold for 2 seconds. Select Options. To do so, press and confirm by pressing Select BL On Time.
Configuring the material calibration function The type calibration function is described in a separate operating manual. 9.10 Changing the password To do so: All of the options must be activated (see "9.4 Activating options"). Press twice or hold for 2 seconds. Select Options.
Operating manual humimeter M30 9.11 Resetting the device to its factory settings To do so: All of the options must be activated (see "9.4 Activating options"). Press twice or hold for 2 seconds. Select Options. To do so, press and confirm by pressing Select Reset.
10.2 Checking the calibration The calibration of the device should be checked every four weeks. Use the optionally purchasable test plate for checking. To do so: The device and the test plate must have a temperature between 20.0 °C and 26.0 °C. The wooden cassette must lie on a wooden table.
Operating manual humimeter M30 10.3 Configuring the material calibration function To do so: The device must have a temperature between 20.0 °C and 26.0 °C. Switch on the device. Press twice or hold for two seconds to enter the main menu level.
10.4 Care instructions • Do not leave the device out in the rain. The device is not waterproof. • Do not expose the device to extreme temperatures. • Protect the device from strong mechanical shocks and loads. 10.5 Cleaning the device ATTENTION Do not clean with fluids Water or cleaning fluid getting inside the device can destroy the device.
Page 40
Operating manual humimeter M30 Fault Cause Remedy Material thickness not Make sure that the minimum sufficient material thickness of 30 mm is given. Incorrect contact pressure Press the device against the material being measured with a pressure of approx. 4 kg.
12. Storage and disposal 12.1 Storing the device The device must be stored as follows: • Do not store outdoors. • Store in a dry and dust-free place. • Protect the device from sunlight. • Avoid mechanical shocks/loads. • Remove the batteries if the device isn't used for a period of 4 weeks or longer •...
Operating manual humimeter M30 13. Device information 13.1 CE declaration of conformity _______________ KONFORMITÄTSERKLÄRUNG DECLARATION OF CONFORMITY Name/ Adresse des Herstellers: Schaller Messtechnik GmbH Max-Schaller-Straße 99 Name/ address of manufacturer: A – 8181 St. Ruprecht Produktbezeichnung: humimeter Product designation: Typenbezeichnung: GE1 ;...
Page 43
Für das angeführte Produkt ist eine vollständige Dokumentation mit Betriebsanleitung in Originalfassung vorhanden. For the mentioned product a complete documentation with manual of instruction in original version is available. Bei Änderungen, die nicht vom Hersteller spezifiziert sind, verliert diese Konformitätserklärung die Gültigkeit.
Page 44
Operating manual humimeter M30 _______________ DECLARATION OF CONFORMITY Schaller Messtechnik GmbH Name/ address of manufacturer: Max-Schaller-Straße 99 A – 8181 St. Ruprecht Product designation: humimeter Type designation: GE1 ; GF2 ; LM5 ; LM6 ; M05 ; M20 ; M30 ; M50...
Page 45
For the mentioned product, a complete documentation with manual of instruction in original version is available. In case of any changes not agreed upon with the manufacturer, this declaration of conformity loses its validity. St. Ruprecht a.d. Raab, 31.07.2022 …............Bernhard Maunz Legal binding signature of the issuer Page 45...
Operating manual humimeter M30 13.2 Technical data Display resolution 0.1 % wood moisture, 0.5 °C/°F temperature Measuring range Dependents on material Operating temperature 0 °C bis +40 °C Storage temperature -20 °C bis +60 °C Temperature compensation Automatic Data memory up to 10.000 measured values...