1.1. General Preventive Measures 1.2. Regulations for equipment that connects to power mains 1.3. Technical warnsigns and explanation 2. Introduction 2.1. About us 2.2. NEO 3. General Product Information 3.1. Scope of delivery 3.2. Control Functions 3.3.Features 4. Installation & Setup 4.1 Physical Installation and Rigging...
Page 3
User Manual 7. Technical Data / Diagrams 7.1 Technical drawings and measurements 7.2 IP Rating 7.3 Technical Data 7.4 Section Chart / DMX-Charts / Color Macro Charts / CCT Chart 7.5 RDM Templates 8. Troubleshooting 9. Manufacturer´s Declaration...
1.1.1. Please read, understand and follow the instructions. 1.1.2. Store the instructions and information in a safe place. Best solution is the ring binder provided by ROXX. 1.1.3. Follow all safety warnings. Under no circumstances remove safety warnings or other information from the equipment.
User Manual 1.1.20. Observe all disposal laws applicable in your country. Especially for the packaging. 1.1.21. Plastic bags are not a toy! Keep away from children! 1.1.22. Please note that changes or modifications which are not approved by the party responsible for compliance will void the user’s authority to operate the device.
User Manual 1.3. Technical warnsigns and explanation In order to prevent the risk of an electric shock, under no circumstances remove the cover/back or open the unit in any way! No user serviceable parts are inside. Service, maintenance and repairs should only be done by qualified service personnel or the manufacturer.
With temperature-controlled fan modes, including fan- off mode for silent operation, NEO is ideal for any stage, TV, and film application. The fixture offers linear CTC control from 2000K to 10,000K, ensuring versatility for any lighting scenario. The user-friendly 2” TFT display, complemented by backlighted buttons, provides direct access to dimmer, CCT, gels, app control, and CRMX functions, simplifying ope- ration for users of all levels.
• 6 extra display controls for direct access of wireless settings, dimmer, CCT, color & user defi nable functions • Master & Slave (by DMX and Wireless DMX) • Wireless DMX (Lumenradio CRMX ® • ROXX App - Bluetooth 5.0 • ROXX NFC App - Near Field Communication 3.3. Features...
220° tilt movement of the fi xtures head. Hanging: On the bottom 3x Camlock 1/4 turn connnectors are installed. Here it´s possible to click in the ROXX Omega Bracket ST (optional accessory) equiped with any suitable clamp. Open...
Do not connect the fixture to an electrical dimmer system, as doing so may cause damage that is not covered by the product warranty! 4.2.2 DC Power ROXX NEO provides a 4-pin DC power input and enables the fixture to run on external battery power under the here below listed technical requirements: DC Battery Voltage Range: 24-34V...
User Manual 4.2.3 DMX Connection The NEO is fully controllable by DMX (USITT DMX512-A standard, based on RS-485) and RDM. It can be connected using either DMX cables or via the built-in LumenRadio CRMX wireless system. 4.2.3.1. Cable Connection If using a cabled DMX system, connect the DMX IN cable to the input connector (male 5-pin XLR connector) and DMX OUT cable to the output (female 5-pin XLR connectors).
Page 12
User Manual 4.2.3.2. Wireless Connection CRMX Disabled Operation Mode n.a. •DMX 19 CH Linked The indicator infront of "DMX" shows that DMX is active. Receive Reset Next Enabled ( 20 ) BLE (Bluetooth) Disabled CRMX Enabled • CRMX(RX) The indicator infront of "CRMX Operation Mode (RX)"...
Additionally, the fi xtures fi rmware can be read out and updated to latest version. For this please make sure NEO stays AC powered during update process.
Once the fixture is connected to AC power, the boot process starts and the following information will appear on the display: “Ready to ROXX”, the product name and the current software version. After this process, the fixture is ready for operation, and starts in the previous- ly enabled mode.
Page 15
User Manual Display Off Pressing ESC + arrow down simultaneously the display backlight function will set to off and the display will turn off immediately. Once a control is pressed the display backlight will turn on. Manual display flip function* The fixture includes an auto display flip function by default.
User Manual 5.4 Configuration Home Screen After boot process the fixture is ready for operation and starts in the previously enabled mode. At home screen the following information will appear, depending on the current operating mode: DMX Adress Operating Mode (DMX Mode, Quick Light or Standalone Mode) Next available DMX address depending on the fixtures DMX footprint External Data protocol (CRMX, DMX, BLE).
User Manual Level 1 Level 2 Menu DMX Mode DMX Mode 3CH CCT Stand Alone 3CH RGB Slave 6CH RGB Settings 8CH RGB 19CH RGB System Info 23CH RGB 4CH DIRECT 8CH DIRECT 9CH DIRECT 21CH DIRECT 26CH DIRECT 17CH HSI 16CH PURE 29CH PURE 28CH FULL ACCESS...
Page 18
User Manual Auto* Select “Auto” by using the up/down arrows and press ENTER. Here at sub-menu (level 3), you can choose between 20 different Auto Programs and Stop Program. Using the Up/ Down arrows you can select one of the 10 auto programs and confirm by pressing ENTER or step back by ESC. After confirming your preferred Auto Program, you can now adjust speed and brightness at level 4.
Page 19
User Manual Editor* At Editor you have up to three customizable programs which can be defined and run from the menus. Each of the three values contains twenty four user-definable scenes with its own values for RGBL (RAW) or RGB (Calibrated) and shutter, playing continuously in a loop.Each scene has a definable fade-in time for the transition from one color to the other and wait-time.
Page 20
User Manual Color Macro* 46 different color macros (34x matched LEE color filters, 6 LED colors and 6 different Whites) are available as presets. For each the brightness can be adjusted separately. Level 1 Level 2 Level 3 Menu Stand Alone Mode Color Macro DMX Mode Stop Stand Alone...
Page 21
User Manual Quick Color* The standalone mode “Quick Color” allows a direct adjustment of the single LED colors R, G, B, L, Dimmer and Shutter. Level 1 Level 2 Level 3 Menu Stand Alone Mode Quick Color DMX Mode Stop Stand Alone Dimmer <0-100>...
Page 22
User Manual Using UP and DOWN controls to select your desired menu item, confirm by ENTER and adjust the desired value by up and down controls and confirm all entries with ENTER. * Note: Tint values = no function/neutral 001 - 127 = + green -001 to - 127 = - green...
Page 23
User Manual Timer* Via the internal timer function, all Stand Alone modes except "Auto" and "Editor" can be conveniently faded in and out after the function is enabled in the previously activated standalone mode, without the need for an external controller. Also it remains active even the fixture is switched off and restarted.
User Manual 5.4.5 Settings Level 1 Menu DMX Mode Stand Alone Slave Settings System Info Main Menu Menu level 2 Menu level 3 Menu level 4 Description CRMX <on/off> On=CRMX enabled / Off= CRMX disabled Receive= CRMX module as Receiver Operating Mode <receive/transmit>...
Page 25
User Manual Main Menu Menu level 2 Menu level 3 Menu level 4 Description On= Auto-Display-Flip-Function enabled Auto Flip <on/off> Off= Auto-Display-Flip-Function disbaled On= controls permanent on, display itself will deactivate after 60 minues of incativity Backlight <on/off> Off= controls and display deactivation after approximately 1 minute of inactivity On= Automatically locks the controls after approximately 1 minute of inactivity.
Page 26
User Manual Main Menu Menu level 2 Menu level 3 Menu level 4 Description The LED responds abruptly to it´s DMX values Dimmer Response The LED responds similar to a halogen fixture Halogen with soft changes at brightness. Normal CRI Color Calibration High CRI Red <0-255>...
Page 27
User Manual Main Menu Menu level 2 Menu level 3 Menu level 4 Menu Level 5 Are you sure to reset? / Confirm by Restores all factory defaults , but not Factory Reset pressing ENTER, cancel with ESC User defaults and no User Colors Restores all User Reset according to the User Preset List.
User Manual Dimmer Curves Linear Exponential Logarithmic S-Curve 5.4.5.1 Reset Functions 1. Via DMX Factory / User Reset only starts if shutter channel has the DMX value “250” at the same time Factory Reset: DMX address and DMX mode stay on the same value as set before the reset. All other settings will set back to default User Reset: DMX address and DMX mode stay on the same value as set before the reset.
User Manual User Reset: Display Query: “> With Add. / Mode No Add. / Mode RESET NOW?” If “With Add. / Mode” is selected, DMX address is set to “1” and DMX mode changes to the mode defined by “User Reset List / DMX Mode”. All other settings will set back to User Reset List. If “No Add.
User Manual 6. ACCESSORIES 6.1 Filters Available fi lters of ROXX NEO with order numbers: Very Narrow 10° Narrow 15° Medium 40° Art.: 14905101 Art.: 14905201 Art.: 14905301 Wide 80° Horizontal 60° x 10° Vertical 10° x 60° Art.: 14905401 Art.: 14905501...
Page 31
User Manual 7. TECHNICAL DATA / DIAGRAMS 7.1 Technical drawings and measurements 497,00 451,50 545,00 32,00 125,00...
Page 32
Manual 7.2 IP Rating ROXX products conform to officially classified IP standard levels. NEO is rated to IP65 when using the covers for the housing parts. IP stands for Ingress Protection and IP65, according to classified standard, means shielded against dust and high-pressure jets of water from any side.
Page 33
User Manual 7.3 Technical Data Photometrics LED expected lifetime 50.000 hours Lightsource 24x 40W RGBL Type of optical system TIR lens LED PWM Frequency selectable 800Hz, 1.200Hz, 2.000Hz, 3.600Hz, 12kHz, 25kHz Beam angles @ Full (50%) 8° (native) Maximum Field angles @ Full (10%) 15°...
Page 34
User Manual 7.3 Technical Data Power Linking 1 unit @ 230V / 0 units @ 100V Power Factor PF 0.993@ 100V / PF 0.977@ 230V Power Supply Unit Inbuilt auto-ranging electronic switch-mode DC Power In 24-34V Operator & Controller 3CH CCT, 3CH RGB, 6CH RGB, 8CH RGB, 19CH RGB, 23CH RGB, 4CH DIRECT, DMX channels 8CH DIRECT, 9CH DIRECT, 21CH DIRECT, 26CH DIRECT, 17CH HSI, 16CH PURE, 29CH PURE, 28CH FULL ACCESS, 44CH FULL ACCESS...
Page 35
User Manual 7.4 DMX-Charts / Color Macro Charts / CCT Chart / Pattern Chart / Section Chart 3CH CCT 9CH DIRECT 3CH RGB 21CH DIRECT 6CH RGB 26CH DIRECT 8CH RGB 17CH HSI 19CH RGB / Default Mode 16CH Pure Mode 23CH RGB 29CH Pure Mode 4CH DIRECT...
Page 36
User Manual Channel 4CH DIRECT 8CH DIRECT 9CH DIRECT 21CH DIRECT 26CH DIRECT 17CH HSI Dimmer Dimmer Dimmer Dimmer Green Red Fine Shutter Shutter Dimmer Fine Dimmer Fine Blue Green Duration Shutter Shutter Lime Green Fine Green Duration Blue Blue Green Saturation Blue Fine...
Page 37
User Manual Channel 16CH PURE 29CH PURE 28 CH Full Acces Channel 44CH Pure Mode Channel 44CH Pure Mode Master Dimmer Master Dimmer Master Dimmer Master Dimmer Segment 2 Blue Segment 2 Blue Shutter Master Dimmer fine Shutter Master Dimmer fine fine Duration Shutter...
Page 38
User Manual 3CH CCT 9CH DIRECT 3CH RGB 21CH DIRECT 6CH RGB 26CH DIRECT 8CH RGB 17CH HSI 19CH RGB / Default Mode 16CH Pure Mode 23CH RGB 29CH Pure Mode 4CH DIRECT 28CH Full Access Mode 8CH DIRECT 44CH Pure Mode 3 CH CCT MODE (Color Calibrated) Function Value...
Page 39
User Manual 8 CH - RGB (Color Calibrated) Function Value Setting Default Dimmer 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open 070 - 084 Strobe 2: opening pulse (fast slow) 085 - 089...
Page 40
User Manual 19 CH RGB Mode (Color Calibrated) - Default mode Function Value Setting Default Dimmer 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open 070 - 084 Strobe 2: opening pulse (fast...
Page 41
User Manual Color Macro affects main & according to Color Macro Chart (override RGB/CTC) pattern background color 000 - 005 no function Color Macro 006-105 0,1s - 10s (0,1s steps) Crossfade (Transition Time 106-214 11s - 119s (1s steps) between Color 215-244 2m - 4m50s (10s steps) Macros)
Page 43
User Manual 23 CH RGB Mode (Color Calibrated) 000-005 Snap from cell to cell Pattern X-fade 006-255 Fade Duration short to long Pattern Red 000-255 0 - 100% Pattern Green 000-255 0 - 100% Pattern Blue 000-255 0 - 100% Device Settings according to Device Settings RGB mode (p.58) 4 CH - DIRECT MODE (RAW Balance)
Page 44
User Manual 170 - 184 Strobe 7: burst pulse (fast slow) 185 - 189 Shutter open 190 - 204 Strobe 8: random burst pulse (fast slow) 205 - 209 Shutter open Shutter 210 - 224 Strobe 9:sine wave (fast slow) 225 - 229 Shutter open 230 - 244...
Page 46
User Manual 21 CH - DIRECT MODE (RAW Balance) Pattern Red 000-255 0 - 100% Pattern Green 000-255 0 - 100% Pattern Blue 000-255 0 - 100% Pattern Lime 000-255 0 - 100% Device Settings according to Device Settings Direct mode (p.60) 26 CH - DIRECT MODE (RAW Balance) Function Value...
Page 47
User Manual 26 CH - DIRECT MODE (RAW Balance) 000-255 0 - 100% Red Fine 000-255 0 - 100% Green 000-255 0 - 100% Green Fine 000-255 0 - 100% affects main & pattern background color Blue 000-255 0 - 100% Blue Fine 000-255 0 - 100%...
Page 48
User Manual 26 CH - DIRECT MODE (RAW Balance) Pattern Red 000-255 0 - 100% Pattern Green 000-255 0 - 100% Pattern Blue 000-255 0 - 100% Pattern Lime 000-255 0 - 100% Device Settings according to Device Settings Direct mode (p.60) 17CH - HSI Mode (Color Calibrated) Function Value...
Page 49
User Manual 17CH - HSI Mode (Color Calibrated) 000 - 004 5600K 2000K-6500K linear in 20-21K steps 005-226 (please see detailed CTC chart) CTC (affects HUE and Saturation) --> 182-182 5600K according to CTC chart CTC no effect if Sa- turation to 100% 226-226 6500K...
Page 50
User Manual 16CH Pure Mode (Color Calibrated ) Function Value Setting Default Master Dimmer 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open 070 - 084 Strobe 2: opening pulse (fast slow)
Page 51
User Manual 16CH Pure Mode (Color Calibrated ) Segment 4 Red 000-255 0 - 100% Segment 4 Green 000-255 0 - 100% Segment 4 Blue 000-255 0 - 100% Device Settings according to Device Settings RGB mode (p.58) 29CH Pure Mode (Color Calibrated) Function Value Setting...
Page 52
User Manual 29CH Pure Mode (Color Calibrated) Segment 1 Green 000-255 0 - 100% Segment 1 Green 000-255 0 - 100% fine Segment 1 Blue 000-255 0 - 100% Segment 1 Blue 000-255 0 - 100% fine Segment 2 Red 000-255 0 - 100% Segment 2 Red fine 000-255...
Page 53
User DMX CHART Manual 28CH Full Access Mode (Color Calibrated) 090 - 104 Strobe 3: closing pulse (fast slow) 105 - 109 Shutter open 110 - 124 Strobe 4: random strobe (fast slow) 125 - 129 Shutter open 130 - 144 Strobe 5: random opening pulse (fast slow) 145 - 149...
Page 54
User Manual 28CH Full Access Mode (Color Calibrated) 000 - 004 5600K 2000K-6500K linear in 20-21K steps 005-226 (please see detailed CTC chart) 182-182 5600K according to CTC chart (affects RGB) 226-226 6500K 6621K-10.000K linear in 120-121K steps 227-255 (please see detailed CTC chart) no function 001-127 Magenta ->...
Page 55
User Manual 44CH Pure Mode (Color Calibrated) Function Value Setting Default Master Dimmer 000-255 0 - 100% Master Dimmer fine 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open...
Page 56
User DMX CHART Manual 44CH Pure Mode (Color Calibrated) 000-005 Snap from cell to cell Pattern X-fade 006-255 Fade Duration short to long Pattern Red 000-255 0 - 100% Pattern Red fine 000-255 0 - 100% Pattern Green 000-255 0 - 100% Pattern Green fine 000-255 0 - 100%...
Page 57
User Manual 44CH Pure Mode (Color Calibrated) Segment 2 Blue 000-255 0 - 100% Segment 2 Blue 000-255 0 - 100% fine Segment 3 Red 000-255 0 - 100% Segment 3 Red fine 000-255 0 - 100% Segment 3 Green 000-255 0 - 100% Segment 3 Green...
Page 58
User Manual Device Setting RGB Modes Settings DMX Value Function remark 000-005 No function Display Backlight On (hold 3s) Display Backlight Off (hold 3s) Display Lock On (hold 3s) Display Lock Off (hold 3s) 010-014 reserved / no function DMX Fail - Blackout (hold 3s) DMX Fail - Hold (hold 3s) DMX Fail - Emergency Light (hold 3s) 018-022...
Page 59
User Manual Device Setting RGB Modes Settings DMX Value Function remark Fan Studio (hold 3s) Fan Off (hold 3s) Fan High Power (hold 3s) 064-068 reserved / no function Redshift (affects only Redshift On (hold 3s) between 2700-3500K) Redshift Off (hold 3s) 071-083 reserved / no function Runtime Off (hold 3s)
Page 60
User Manual Device Setting DIRECT Modes Settings DMX Value Function remark 000-005 No function Display Backlight On (hold 3s) Display Backlight Off (hold 3s) Display Lock On (hold 3s) Display Lock Off (hold 3s) 010-014 reserved / no function DMX Fail - Blackout (hold 3s) DMX Fail - Hold (hold 3s) DMX Fail - Emergency Light (hold 3s) 018-022...
Page 61
User Manual Device Setting DIRECT Modes Settings DMX Value Function remark Fan Studio (hold 3s) Fan Off (hold 3s) Fan High Power (hold 3s) 064-068 reserved / no function Redshift (affects only bet- Redshift On (hold 3s) ween 2700-3500K) Redshift Off (hold 3s) 071-083 reserved / no function Runtime Off (hold 3s)
Page 62
User Manual Color Macro Chart Gels - Color Macros for DMX Gels - Color Macros for DMX DMX value Gel Name Color Number DMX value Gel Name Color Number 000-005 no function 102-104 Special Med Lavender LEE 343 006-008 100% Red LED 105-107 Ultimate Violet LEE 707...
Page 63
User Manual Color Macro Chart Gels - Color Macros for Standalone Mode Gels - Color Macros for Standalone Mode Position Gel Name Color Number Position Gel Name Color Number 100% Red LED Lavender LEE 058 Fire LEE 019 Magenta LEE 113 Medium Red LEE 027 Mauve...
Page 64
Section Chart Below you can see the layout of the controllable sections for the NEO: Below you can see the layout of the controllable sections for the NEO, when „Invert“ is activated in settings: CTC channel DMX / Color temperature 10.000...
Page 65
User Manual CTC-Chart Color Color Color Color Color Color Temp Temp Temp Temp Temp Temp (Step) (Step) (Step) (Step) (Step) (Step) (°K) (°K) (°K) (°K) (°K) (°K) 5600 4525 2774 3649 5400 6276 5600 4545 2794 3670 5421 6296 5600 2814 3690 4566...
Page 66
0137 xxxx * Note: During RDM identifying process NEO flashes white to blue color alternately. RDM functions For easy identifying ROXX NEO during RDM process the unit will jump from white color to blue color every second. Function Action Values...
Page 67
Bluetooth is disabled at your mobile Please eanble Bluetooth at your mobile device device settings. Please use same Bluetooth Pin to connect ROXX. Mobile device has wrong Bluetooth Pin APP with the fixture. Current BLE Pin can be read out inside fixture´s wireless DMX settings.
Page 68
ROXX GmbH, Hansestr. 91, 51149 Köln Email: info@roxxlight.com or the ROXX authorized reseller in your country, from where you purchased your product. Correct Disposal of this product This is for the European Union and European countries with electrical waste collection systems. When this label is shown on the product or brochure it means that the item cannot be disposed with household waste.
Page 69
User Manual CE Compliance The equipment marketed by ROXX GmbH complies (where applicable) with the essential requirements and other specifications of the following Directives: • 2014/53/EU (RED) • 2014/30/EU (EMC) • 2014/35/EU (LVD) • 2011/65/EU (RoHS) The complete EU- and UK-Declaration of Conformity can be found at www.roxxlight.com/support, or you can also request it at info@roxxlight.com...