ADF Web AXIS HD67401-E4V User Manual

Can - repeater - extender bus line

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 2.100
English
CAN - Repeater – Extender bus line
(Order Codes: HD67401-E4V – HD67401-E7R CAN 2.0A & 2.0B
HD67402-E4V – HD67402-E7R CANopen
HD67403-E4V – HD67403-E7R DeviceNet
HD67404-E4V – HD67404-E7R J1939/NMEA2000)
For Website information :
www.adfweb.com?Product=HD67401
www.adfweb.com?Product=HD67402
www.adfweb.com?Product=HD67403
www.adfweb.com?Product=HD67404
Benefits and Main Features:
Very easy to configure
Wide supply input range
Electrical isolation
Industrial temperature range:
-40°C / 105°C (-40°F / 221°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
User Manual CAN – Repeater – Extender bus line
Document code: MN67401_ENG
Revision 2.100
For others Repeaters:
CAN Repeaters
See also the following links:
www.adfweb.com?Product=HD67117
www.adfweb.com?Product=HD67180
www.adfweb.com?Product=HD67181
www.adfweb.com?Product=HD67182
Optic Fibres Repeaters
See also the following links:
www.adfweb.com?Product=HD67117F
www.adfweb.com?Product=HD67117FSX
www.adfweb.com?Product=HD67180F
www.adfweb.com?Product=HD67180FSX
www.adfweb.com?Product=HD67181F
www.adfweb.com?Product=HD67181FSX
www.adfweb.com?Product=HD67182F
www.adfweb.com?Product=HD67182FSX
www.adfweb.com?Product=HD67221F
www.adfweb.com?Product=HD67221FS
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
in India
in India
in India
in India
Page 1 of 28
(For CANopen)
(For DeviceNet)
(For CAN 2.0A & 2.0B)
(For J1939)
(For CANopen)
(For CANopen)
(For DeviceNet)
(For DeviceNet)
(For CAN 2.0A & 2.0B)
(For CAN 2.0A & 2.0B)
(For J1939)
(For J1939)
(Copper Bridge)
(Copper Bridge)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AXIS HD67401-E4V and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADF Web AXIS HD67401-E4V

  • Page 1 User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 1 of 28 Industrial Electronic Devices User Manual Revision 2.100 English CAN - Repeater – Extender bus line (Order Codes: HD67401-E4V – HD67401-E7R CAN 2.0A & 2.0B HD67402-E4V –...
  • Page 2: Table Of Contents

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 2 of 28 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 3 of 28 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 4 of 28 Industrial Electronic Devices EXAMPLES OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 5 of 28 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD6740x-E4x-xxx ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6 User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 6 of 28 Industrial Electronic Devices Figure 1b: Connection scheme for HD6740x-E7x-xxx ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 7: Characteristics

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 7 of 28 Industrial Electronic Devices CHARACTERISTICS: “HD67401, HD67402, HD67403, HD67404” series are rugged devices that can be located on cars, trucks, trains, boats and any other machine that needs to isolate / repeat a portion of CAN bus network (CAN 2.0A &...
  • Page 8: Power Supply

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 8 of 28 Industrial Electronic Devices POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below.
  • Page 9: Leds

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 9 of 28 Industrial Electronic Devices LEDS: The device has got four LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: USB cable inserted...
  • Page 10: Can

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 10 of 28 Industrial Electronic Devices CAN: The connection of both CAN (CAN0 and CAN1) in the HD6740x-E4x-xxx device must be made with a 3way MiniFit Female connector. The pinout of Male Mini-Fit connector of the board is at right side of the page.
  • Page 11: Usb

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 11 of 28 Industrial Electronic Devices USB: The USB port is used to start the converter in Boot Mode and to program the converter. It is necessary to use a Micro USB type B cable. ADFweb.com Srl –...
  • Page 12: Use Of Compositor Sw6740X

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 12 of 28 Industrial Electronic Devices USE OF COMPOSITOR SW6740X: To configure the Converter, use the available software that runs with Windows called SW6740X. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 13: New Project / Open Project

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 13 of 28 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “CAN –...
  • Page 14: Software Options

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 14 of 28 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 15 User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 15 of 28 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 16: Set Communication

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 16 of 28 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of converter. By Pressing the “Set Communication” button from the main window for SW6740X (Fig. 2) the window “Set Communication”...
  • Page 17: Update Device Can

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 17 of 28 Industrial Electronic Devices UPDATE DEVICE CAN (ONLY FOR THE HARDWARE WITHOUT USB PORT): By pressing the “Update Device” button it is possible to load the created Configuration into the device;...
  • Page 18: Update Device Usb

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 18 of 28 Industrial Electronic Devices UPDATE DEVICE USB: By pressing the “Update Device USB” button it is possible to load the created Configuration into the device, and also the Firmware if is necessary, using the USB port.
  • Page 19 User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 19 of 28 Industrial Electronic Devices Note: When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD6740X device. Note: When you receive the device, for the first time, you have to update also the Firmware in the HD6740X device.
  • Page 20: Download Conf

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 20 of 28 Industrial Electronic Devices DOWNLOAD CONF.: By pressing the “Download Conf. CAN” or “Download Conf. USB” button, it is possible to download the Configuration that is inside the device into the opened project.
  • Page 21: Mechanical Dimensions

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 21 of 28 Industrial Electronic Devices MECHANICAL DIMENSIONS: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 22 User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 22 of 28 Industrial Electronic Devices Type A ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 23 User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 23 of 28 Industrial Electronic Devices Type B ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 24 User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 24 of 28 Industrial Electronic Devices Type C ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 25: Ordering Informations

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 25 of 28 Industrial Electronic Devices ORDERING INFORMATIONS: The ordering part number is formed by a valid combination of the following: HD6740X – E y z – s d f Fixing lugs A: Type 1 B: Type 2...
  • Page 26: Accessories

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 26 of 28 Industrial Electronic Devices ACCESSORIES: Order Code: AC34001 Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V AC Order Code: AC34002 Rail DIN - Power Supply 110V AC 50/60Hz –...
  • Page 27: Disclaimer

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 27 of 28 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 28: Warranties And Technical Support

    User Manual CAN – Repeater – Extender bus line Document code: MN67401_ENG Revision 2.100 Page 28 of 28 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents