Performance Parameters 9 - Haier HSU-12LA10 Owner's Manual

Split wall mounted type
Hide thumbs Also See for HSU-12LA10:
Table of Contents

Advertisement

Model
Power
Rated cooling capacity(W)
Rated heating capacity(W)
Rated input
Heat pump
power(W)
Aux-heat
3
Air flow volume(m /h)
Dehumidifying capacity (L/h)
Waterproof class
Protection class
Climate type
Refrigerant(
R22
)charge amount(g)
Indoor
Noise(dB(A))
Outdoor
Indoor
Net weight(kg)
Outdoor
Indoor
Dimension WxHxD
(mmxmmxmm)
Outdoor
NOTICE
1.The indicated noise parameter is measured in laboratories before leaving factory.
2.The rated cooling/heating capacity is tested under the following conditions:
Cooling operation
Heating operation
3.Due to the policy of constant development, we reserve the right to modify technical data without
notice. While errors and omissions are a possibility, every reasonable effort has been made to
ensure that the information in this manual is correct.
4.Operating temperature range:
Indoor side DB/WB(
Outdoor side DB/WB(
5.Wiring diagram of air conditioner (indoor unit/outdoor unit) are attached to the indoor/ outdoor unit
respectively.
6.If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
9 9
Cool
Indoor
27 (DB)
Indoor
20 (DB)
Maximum cooling Minimum cooling Maximum heating Minimum heating
)
32/23
C
43/26
C
)
PERFORMANCE PARAMETERS
IP20(INDOOR) IP24(OUTDOOR)
Outdoor
19 (WB)
Outdoor
15 (WB)
21/15
21/15
I
T1
35 (DB)
7 (DB)
27/--
24/18
24 (WB)
6 (WB)
20/--
-5/-6