Sensible Cooling Value-Temperature Curves - Haier HSU-12HSA03 Service Manual

Domestic air conditioner
Table of Contents

Advertisement

6.5 Sensible cooling value-temperature curves

HSU-09HSA03/R2(DB)
Indoor temp.
18
DB/WB
18/12
1885
18/14
1917
20/15
1982
22/16
2061
25/18
2137
27/19
2232
30/22
2320
32/23
2430
32/24
2501
Haier air conditioner
Sensible cooling value - Temperature table
Outdoor temp. (Humidity 46%)
20
25
1783
1720
1866
1800
1920
1845
1969
1935
2066
2003
2132
2063
2261
2192
2348
2260
2404
2302
32
35
1647
1489
1720
1545
1764
1634
1870
1691
1961
1774
2020
1885
2147
1941
2181
2051
2218
2056
- 71-
Edition: 20070116
40
43
46
1400
1315
1236
1489
1400
1310
1536
1408
1315
1562
1445
1347
1667
1491
1366
1713
1570
1459
1769
1630
1486
1834
1699
1562
1920
1723
1574

Hide quick links: