Haier HSU-12HSA03 Service Manual page 25

Domestic air conditioner
Table of Contents

Advertisement

in 7s resound 7 times.
b. Then operation as following program: Enter min capacity rated frequency operation; panel show
cool status; have ration in communication.
Enter rated frequency operation; Panel show cool status; have ration in communication.
c. Exit condition Exit rated operate mode and enter remote control set status after received remote
control signal.
.Fault explain
LCD fault code
Indoor unit fault code
Fault code
Contents
E1
Room temperature sensor fault
E2
Heat exchange sensor fault
E3
Total current Over Current
E4
EEPROM error
E5
Cool icing
E6
Reset
E7
Communication fault(between indoor and outdoor unit)
E8
communication between panel and indoor unit
E9
High load protection
E10
Humidity Sensor
E11
Stepping motor fault
E12
High voltage static electricity apparatus
E13
Power off moment
E14
Indoor fan motor fault
E15
Central control fault
E16
High voltage electrostatic dust collection fault
E17
reserved
E18
reserved
E19
reserved
Outdoor unit fault code
Fault code
Contents
F1
Module fault (overheat, over current, short circuit)
F2
No load
F3
Communication fault
F4
Compressor overheat
F5
Total current Over Current
Haier air conditioner
- 25 -
Edition: 20070116
Remark
Use in split unit
Heat overload
Remark
Ventilation
temperature
protection