6.2.1 Cooling capacity-temperature curves

HSU-09HSA03/R2(DB)
Indoor temp.
DB/WB
18/12
18/14
20/15
22/16
25/18
27/19
30/22
32/23
32/24
Haier air conditioner
Cooling value - Temperature table
Outdoor temp. (Humidity 46%)
18
20
25
2383
2313
2243
2534
2460
2386
2610
2537
2460
2672
2625
2580
2849
2754
2671
2940
2842
2750
3045
3015
2923
3240
3173
3077
3342
3277
3208
32
35
2196
1986
2336
2060
2409
2179
2493
2254
2615
2365
2693
2486
2862
2588
2971
2724
3141
2841
- 57-
Edition: 20070116
40
43
46
1866
1669
1518
1986
1811
1615
2048
1854
1666
2082
1838
1729
2187
1963
1780
2247
2029
1862
2394
2140
1979
2527
2285
2083
2670
2405
2172