Installation Manual of Room Air Conditioner

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
Accessory parts
No.
Accessory parts
1
Remote controller
2
R-03 dry battery
3
Mounting plate
4
Drain hose
4X50
5
Steel nail, cement
6
4X25
Plastic cap
Screw
7
Cover
8
Cushion
9
Pipe supporting plate
10
Drain-elbow
No.0010531057
Necessary Tools for Installation
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
Drawing for the installation of indoor and outdoor units
Number
of
articles
1
Optional parts for piping
Mark
Parts name
2
A
Non-adhesive tape
Adhesive tape
B
1
C
Saddle(L.S) with screws
Connecting electric cable
D
for indoor and outdoor
1
Drain hose
E
F
Heating insulating material
6
Piping hole cover
G
4
1
Arrangement of piping directions
4
Left
1
1
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
Rear left
Rear
right
Right
Below
The marks from
A
The distance between the indoor unit and the floor should be
more than 2m.
9.Nipper
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Attention must be paid to
the rising up of drain hose
to
G
in the figure are the parts numbers.
12.Reamer
A
C
D
E

Advertisement

loading

Summary of Contents for Haier HSU-12H03

  • Page 1: Installation Manual Of Room Air Conditioner

    Arrangement of piping directions Cushion Rear left Rear Left right Pipe supporting plate Right Below Drain-elbow The marks from in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m. No.0010531057...
  • Page 2 2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
  • Page 3: Connecting The Indoor/Outdoor Electric Cable

    Two ways for the installation of indoor part, as illustrated: Way One : When the pipes go from the back of the indoor unit, you can connect the fresh air tube with the outlet joint on the two sides of the frame,and then fix it at the pipe exit of the frame Way Two : When installing the side outlet pipe,connect the fresh tube and the outlet joint ,and then fix it on the left side or right side of the frame.Outlet pipe is connected with the pipe hole cover by the pipe lid.
  • Page 4: Connection Of Pipes

    Outdoor unit 1.Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. The max vertical distance between the indoor unit and the outdoor unit is 5 m.