Arrangement of piping directions Cushion Rear left Rear Left right Pipe supporting plate Right Below Drain-elbow The marks from in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m. No.0010531057...
Page 2
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
Two ways for the installation of indoor part, as illustrated: Way One : When the pipes go from the back of the indoor unit, you can connect the fresh air tube with the outlet joint on the two sides of the frame,and then fix it at the pipe exit of the frame Way Two : When installing the side outlet pipe,connect the fresh tube and the outlet joint ,and then fix it on the left side or right side of the frame.Outlet pipe is connected with the pipe hole cover by the pipe lid.
Outdoor unit 1.Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. The max vertical distance between the indoor unit and the outdoor unit is 5 m.