® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE USE OF THE HYDRAULIC FUNCTIONS OF THE BOOM Boom lock ........................................49 Unfolding ........................................49 Up / Down ........................................50 Folding ..........................................51 ALARM CONFIGURATION START SPRAYING USEFUL INFORMATION WHILE SPRAYING...
Page 4
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE GENERAL WARNINGS AND PRECAUTIONS DANGER! WARNING! PRESSURISED SPRAY SYSTEM • Read and follow instructions. If instructions are unclear after reading the manual, please contact a local dealer. • It is important to recognise proper safety precautions when using a pressurised spray system. Fluids under pressure can penetrate skin and cause serious personal injury.
Page 5
® SPRAY JOB COMPUTER IC45-DYNARATE CAUTION! HARNESS CABLE AND HOSE SAFETY • Routinely check all harness cables and hoses for damage or wear. Replace or repair when necessary. • Do not route harness cables and hoses with sharp bends. • Do not strap harness cables and hoses to lines with high vibration or spikes in pressure.
INTRODUCTION Opens the settings menu. Returns to the previous screen The start-up of the IC45-DynaRate work screen will depend on the If after several minutes the IC45 work screen does not appear, Available on the main working screen type of installation of your equipment: please contact the dealer who sold you the equipment.
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE Customization of the data displayed on the screen Description of the function keys The key set may be different depending on your sprayer’s The configurable information zones are located in the dark bands features.
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE Graphic indicators Show/hide Pressure Bargraph and Tank volume The center of the screen displays information about the status of Note 1: The display of the Pressure / Droplets and Tank the sprayer in real time.
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE Display of alarms Unlocking the IC45 options The IC45 has an alarm system (see alarm settings on page XX) To unlock additional functions available as options, you must enter a code (to be purchased through your dealer).
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE Calibration / Speed sensor CHAPTER 2 – AT THE BEGINNING OF THE SEASON Establish the speed source As there are several speed sensors fitted either on the tractor/ IMPORTANT motor engine or on the implement (attached sprayer), you may...
Page 12
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE Calibration / Flow Sensor Calibrate speed source The calibration of the speed is done by driving a marked distance. Calibration of the flow sensor is done either: The distance to be covered is 100 meters.
Page 13
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE Calibration / Pressure sensor Once these the two steps described on the previous page completed, no further pressure calibration is required for the perfect sprayer operation. Calibration of the pressure sensor is done in two steps.
Page 14
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE Step 3: Calibration / Tank level sensor Calibrate the maximum level of the tank “Tank Max Level” is a data pre-defined by the manufacturer in the The calibration of the tank gauge is done in 4 steps with 3 instantaneous measurements and 1 multipoint measurement OEM Menu.
• The remaining parameters will be automatically filled in with the technical data of the nozzle and the flow rate provided by TeeJet Technologies. TeeJet nozzle information cannot be changed. General and User Nozzle series nozzle information should be entered on the appropriate lines.
Page 16
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE Presetting a thrid party nozzle (user nozzle) Then return to the NOZZLE PRESETS screen, by pressing the return button. Note : TeeJet nozzles are already pre-registered, to preselect them see procedure on previous page.
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE HOW TO USE SIMULATED SPEED TO TEST A SPRAYER STOPPED Other nozzle preset functions The following keys can be used to simulate a speed to test the The following button resets the User Nozzle list to sprayer settings before working, while remaining stationary.
® SPRAY JOB COMPUTER IC45-DYNARATE The simulated speed values (fast/slow) are set as follows: MAIN MENU MACHINE JOB SETTINGS OPERATION Press the lines to change the speed settings if you want to simulate other speed values for the low (tortoise) or high (hare) speed.
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE CHAPTER 3 - USE AND SPRAYING Agitation during spraying ENTERING THE SPRAYING PARAMETERS VIA JOB WIZARD NOTE: The agitation mode may not appear in your configuration. Agitation mode will be available in function of your sprayer configuration.
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE CHOICE OF REGULATION MODE SETUP OF THE DOSE ADJUST STEPS: How to switch between Manual and You may want to customize the percentage of the target rate Automatic modes adjustment performed by one pressing of the adjustment keys.
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE FILLING THE SPRAYER TANK The tank filling can be controlled on various levels depending on: – and the features of your job computer (is it fitted with the Manual mode TankMatic option or not) –...
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE – WITH THE COMPUTER CONTROLS With a featured sprayer, the filling is started by simply pressing the “Filling Status” line to toggle the button ON (green). This will turn the automatic fill valve ON and display the Press the calculator to access the tank filling menu.
Page 23
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE ADVANCED FILLING MODE (FOLLOWING): Enter the dose per hectare in the Application Rate screen and the Enter the desired volume to be filled into the tank with the central required values in each of the other lines, using the right/left and...
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE START-UP FILLING AND FILLING STATUS WITH THE EXTERNAL REMOTE SCREEN A tap is displayed on the screen indicating the remaining volume to be filled to reach the required volume. The fill button of the remote screen Display the calculator by pressing the corresponding button.
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE Start of the agitation USE OF THE HYDRAULIC FUNCTIONS OF THE BOOM Once the tank filled up, you may want to keep the spray solution Boom Lock properly mixed while you are driving toward the field or during the When driving on the road, the boom’s pendular suspension must be locked for safety.
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE This screen may feature several key pages, depending on the Folding sprayer type and configuration, and will also display the Spray Boom’s pendular suspension lock/unlock button. To fold the boom, first lock the boom’s pendular...
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE ALARM CONFIGURATION START SPRAYING Accessible from the Main menu, the alarm settings page allows you to choose the events that will trigger a visual alert on the When all settings are completed and the sprayer is ready for work, screen during the work.
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE USEFUL INFORMATION WHEN SPRAYING STATUS BAR During the work, a selection of data is permanently displayed on The gray status bar at the bottom of the screen displays icons the screen in the configurable information areas.
® SPRAY JOB COMPUTER IC45-DYNARATE SECTIONS CONTROL ON THE SCREEN 4 - AFTER SPRAYING The function key pages on the work screen include commands to turn on and turn off spray boom sections. On the graphic display, the sections are represented by rectangles under...
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE AFTER SPRAYING ALARM LOG Displayed on the work screen pages, the button The alarm log will assist the user or service technician to get an TASK COUNTER on the right accesses the logbook that records overview of the most common issues and thereby make it easier alerts that occur during the work.
® ® SPRAY JOB COMPUTER IC45-DYNARATE SPRAY JOB COMPUTER IC45-DYNARATE DIAGNOSTICS DIAGNOSTIC OF ACTUATORS Go to MENU > HELP > Test Outputs This section accesses test and maintenance functions. to test the operation of the valve actuators: master valve, Go to...
Need help?
Do you have a question about the IC45-DYNARATE and is the answer not in the manual?
Questions and answers