Cool Mode; Fan Mode - GE AJCS12DCB Owner's Manual And Installation Instructions

Room air conditioner
Hide thumbs Also See for AJCS12DCB:
Table of Contents

Advertisement

ge.com
COOLMODE
Remote C ontrol
l. Px_ss COOLpad.
2. Px_ss LOW. IVIED or HIpads to set desired fire speed.
3. PI_SS the
INCREASEA/DECREASEV
pads to set the
desix_d temperature
60°F to 85°F in l °F increments.
Control P anel
l. Pxess fl_e MODEpad until tile COOL indicator lig]lt is
lit and the LOW. MEDor Hlin(ficator light is lit tbr
die (lesix_(1t_m speed.
2. Px>ss the INCREASEA/DECRFAISET pads to set the
(Iesix_d temperature
60°F to 85°F in l °F increments.
A them_osmt is used to maint_fin the room
tempenmtre.
Tile compressor will wcle on and off
to keep tile room at the set level of comtbrt. Set die
thermostat at a lower number and die indoor air will
become
coolex;
Set tile thermostat
at a higher
nmnber
and the indoor
air will become
_mnex:
NOTE: ff theair conditioner i s off andis thenturnedon
whileset toCOOL, it willtakeapproximately 3minutesfor
thecompressor tostartandcoolingtobegin.
CoolingDescriptions
ForNormalCooling--Select
the COOL mode and
HIGHor MEDtim with a middle set temperature.
ForMaximum Cooling--Select tile COOLmode
and HIGHtim with a lower set tempemtm>.
ForQuieter& NighttimeCooling--Select the COOL mode
and LOWfimwidi a middle set temperature.
NOTE: If youswitchfroma COOL s ettingtoOFF or to
a fansetting,wait atleast3 minutes beforeswitchingback
toa COOL s etting.
Fan Switch
The tim switch is located behind the ti'()nt grille on the
control box. Access through a hole in control box.
_,_]mn set at
CYCLE (do_n)
the tbn e',cles on and ottl
When set at
CONT (confimtous, tip)
the tim runs
all
the
time providing a mi/x_ balanced mmperau/x_.
The unit
is shipped in the
CONrsetting.
FAN MODE
Use the FAN mode to provide _dr circulation and
filtering without cooling. Since fire only settings do not
provkle cooling, a temperature
setting will not be
displa}ed.
Remote Control
Px>ss FAN pad. Press LOW, MEDor HI pads to set
(lesix_(1 fire speed.
Control Panel
Pxess die MODEpad until the FANindicator light is lit
and the LOW, MEDor HIin(ficator light is lit for the
(lesix_(1 f_m speed.
Vent Control
The vent control is located behind the ti'ont grille on
the right side of the air (fischarge area. "_\lmn set at
CLOSE, only tile air inside fl_e room will be circulated
and conditioned.
When set at OPEN,some inside air is
exhausted outside.
To opeil
or
close
tile
vent:
1. Remove the ti'ont grille.
2. Remo\ e the vent card scx_.
3. Remove vent card, turn it over and replace it b}
locating rear hole in card over locating pin inside air
discharge and reattaching
scre_ at fi'ont.
Theunit leavesthe factoryset at theCLOSE position.
._Locating hole
Screw hole "_.
OPEN position
(Meshendtowardback)
Screwho
CLOSE position
(Meshendtowardfront)
A# Direction
Hofizont_fl lomers
on fl_e Ii'ont grille let
you control the air
(lirection up and
douvI/.
Remove tile fi'ont
grille to a@/st the
vertical lou\'ers
side-to_ide to
dixect the air
left or fight.