Time Flow Recess Adaptor Installation and Maintenance Instructions TFC794R technical data Working Pressure Range Min 50 kPa Max 500 kPa Recommended Pressure 250 - 300 kPa Maximum Static Pressure 1000 kPa (For testing purposes / system commissioning) Maximum Working Temperature 70°C 5/8”...
installation WALL/ • All supply lines must be flushed thoroughly to remove debris TILE SURFACE prior to the installation of this product, as per AS/NZS 3500.1. Strainers (40 mesh) are recommended if debris is an ongoing problem. • A thermostatic mixing valve and a pressure reduction valve may be required to comply with maximum temperature and pressure requirements.
FLOW ADJUSTMENT The flow rate can be adjusted without shutting off the water supply or removing the mechanism. 1. Pull out the colour indicator in the centre of push button. 2. Insert a 3mm Allen key into the slot in the centre of push button.
maintenance TIME FLOW CARTRIDGE- CLEANING If the automatic shut-off takes too long or if there is continuous flow: 1. Unscrew cartridge [3] from body [4] and pull off Time Flow Chamber [12]. 2. Clean the inside of the Time Flow Chamber [12] using a clean, dry cloth, and clean the calibrated groove [11] with a non-metallic, sharp point.
troubleshooting PROBLEM CAUSE RECTIFICATION Water runs constantly / Debris fouling time flow Dismantle cartridge and clean. leaking from outlet cartridge If problem persists, replace components using service kit or replace cartridge. If debris is an ongoing problem, install a strainer (40 mesh) upstream Scale build up on time Dismantle cartridge and clean...