Sensafe Spa Exact Z Quick Start Manual

Sensafe Spa Exact Z Quick Start Manual

Advanced photometer system

Advertisement

Quick Links

Spa
ADVANCED PHOTOMETER SYSTEM
DIGITAL ACCURACY FOR BETTER SPA CARE
Certified to
NSF/ANSI Standard 50
QUICK START GUIDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Spa Exact Z and is the answer not in the manual?

Questions and answers

Summary of Contents for Sensafe Spa Exact Z

  • Page 1 ADVANCED PHOTOMETER SYSTEM DIGITAL ACCURACY FOR BETTER SPA CARE Certified to NSF/ANSI Standard 50 QUICK START GUIDE...
  • Page 2: Table Of Contents

    CONTENTS Welcome..........
  • Page 3: Spa Exact ® Ez Overview

    4. Replace the base fi rmly with pressure while tightening the screw. The meter will turn on automatically. 5. Tighten the screw with #4 Phillips head screwdriver. Be SCREW sure not to over tighten. Unscrew to remove base Sensafe.com...
  • Page 4: Fill, Dip, Read

    FILL, DIP, READ TOTAL ALKALINITY TEST PROCEDURE POWER ON PHOTOMETER Press the button to power on the Spa eXact ® FILL CELL Before testing, rinse CELL and clean with brush thoroughly. Finally rinse the cell 3 times with FILL the water sample to be tested, then cell to capacity to begin test.
  • Page 5 If result reads “HI”, repeat steps 5-7 with a Total Alkalinity Range Extender Strip (part no. 486665) until a numerical value is displayed; Count how many AL Range Extender strips were used; each strip adds 130 ppm to the fi nal result. Sensafe.com...
  • Page 6: Total Bromine

    FILL, DIP, READ TOTAL BROMINE TEST PROCEDURE POWER ON PHOTOMETER Press the button to power on the Spa eXact ® FILL CELL Before testing, rinse CELL and clean with brush thoroughly. Finally rinse the cell 3 times with FILL the water sample to be tested, then cell to capacity to begin test.
  • Page 7 CAP CELL AND READ RESULTS READ Place the Cell Cover onto the CELL and result displayed as Total Bromine. This result is automatically stored in the bR(1) menu. After testing is complete, rinse the sample cell immediately and clean with brush. Sensafe.com...
  • Page 8: Calcium Hardness

    FILL, DIP, READ CALCIUM HARDNESS TEST PROCEDURE POWER ON PHOTOMETER Press the button to power on the Spa eXact ® FILL CELL Before testing, rinse CELL and clean with brush thoroughly. Finally rinse the cell 3 times with FILL the water sample to be tested, then cell to capacity to begin test.
  • Page 9 CAP CELL AND READ RESULTS READ Place the Cell Cover onto the CELL and result displayed as Calcium. This result is automatically stored in the CA(5) menu. After testing is complete, rinse the sample cell immediately and clean with brush. Sensafe.com...
  • Page 10: Free Chlorine

    FILL, DIP, READ FREE CHLORINE TEST PROCEDURE POWER ON PHOTOMETER Press the button to power on the Spa eXact ® FILL CELL Before testing, rinse CELL and clean with brush thoroughly. Finally rinse the cell 3 times with FILL the water sample to be tested, then cell to capacity to begin test.
  • Page 11 CL(3) menu. After testing is complete, rinse the sample cell immediately and clean with brush. IMPORTANT! Do not empty the CELL if you are also testing for Combined Chlorine. You will need the sample. Sensafe.com...
  • Page 12: Combined Chlorine

    FILL, DIP, READ COMBINED CHLORINE TEST PROCEDURE This procedure is a continuation from Free Chlorine Test Method on previous pages. DO NOT DISCARD SAMPLE FROM FREE CHLORINE TEST. ZERO METER Place the Cell Cover onto the CELL and press and the LCD Display reads 0.00 REMOVE STRIP Remove one eXact Strip Micro CL (DPD-3) (Part No.
  • Page 13: Exact ® Strip Micro Cl Interferences

    Peroxides Interference is possible. Typical pH samples of potable water with a pH of 6.0 to 9.0 are OK. If outside this range adjust to pH 6.0 to 7.0 using acid (0.5N Sulfuric acid) or base (0.5N Sodium hydroxide). Sensafe.com...
  • Page 14 FILL, DIP, READ POWER ON PHOTOMETER Press the button to power on the Spa eXact ® FILL CELL Before testing, rinse CELL and clean with brush thoroughly. Finally rinse the cell 3 times with FILL the water sample to be tested, then cell to capacity to begin test.
  • Page 15 CAP CELL AND READ RESULTS READ Place the Cell Cover onto the CELL and result displayed as pH. This result is automatically stored in the PH(2) menu. After testing is complete, rinse the sample cell immediately and clean with brush. Sensafe.com...
  • Page 16: Acrylic Calibration Key

    If variation is greater, please re-check your ZERO procedure (steps 3-4 on page 10) and be sure to use clean water (deionized or distilled if necessary). Acrylic Calibration Key Records: ©2023, Industrial Test Systems, Inc. Printed in USA Sensafe.com...
  • Page 17: For Best Accuracy

    Even if all pads are not immersed in water, DO NOT BEND THE STRIP. Make sure the strip touches the bottom of the CELL while dipping the strip for 20 seconds. To ensure lab quality results, it is recommended to clean the cell with the brush provided after every test. Sensafe.com...
  • Page 18: Troubleshooting

    (803) 329-9712. HEADQUARTERS - INDUSTRIAL TEST SYSTEMS TEMS 1875 Langston Street | Rock Hill, SC 29730 (800) 861-9712 | (803) 329-9712 its@sensafe.com | SENSAFE.COM SENSAFE_ITS ITSSENSAFE SENSAFE EUROPEAN DISTRIBUTION OFFICE - ITS EUROPE LTD. UK Centre for Homeland Security...
  • Page 19: About

    If the meter is faulty or otherwise defective contact ITS by phone (+1-803-329- 9712 Ext. 0) or email (its@sensafe.com) to describe the problem and obtain a return authorization form before returning the photometer to ITS. Damage caused by improper packing of the photometer for return shipment to ITS will not be covered by the warranty.
  • Page 20: Compliance Testing (Usepa)

    ABOUT COMPLIANCE TESTING This DPD test system for Chlorine is accepted for reporting by most health departments because the tests are USEPA (DIN Standard 38 408 G4/G5, ISO 7393/2) accepted for testing requirements for Free Chlorine. The compliance requirement is a photometer wavelength to measure between 490 and 530nm.
  • Page 21: Mahc And Nsf/Ansi 50 Certification

    L1, L2 or L3, with L1 being the highest accuracy rating. TEST RANGE ACCURACY RATING POOL PARAMETERS Total Bromine 0.0 - 17 ppm Combined Chlorine 0.01 - 12 ppm Free Chlorine 0.0 - 12 ppm 6 - 8.4 pH Sensafe.com...
  • Page 22: Other Exact Photometers

    OTHER EXACT PHOTOMETERS ® Part No. 486101 SMART PHOTOMETER SYSTEM ® EXACT IDIP PHOTOMETER SYSTEM EXACT IDIP PHOTOMETER SYSTEM ® TESTS INCLUDE: ( *INCLUDED IN APP Total Alkalinity* Cyanuric Acid Total Bromine Calcium Hardness Chloride (as Salt) Nitrate & Nitrite Free Chlorine* Phosphate Total Chlorine...
  • Page 23 TESTS INCLUDE: ( *INCLUDED IN APP Total Alkalinity* Total Chlorine Ammonia Magnesium Calcium Hardness UH Nitrate & Nitrite Chloride (as Salt) Phosphate Free Chlorine* pH-II* and many more... eXact iDip Part No. 486207 ECO-CHECK EXACT EZ PHOTOMETER ® eXact iDip Sensafe.com...
  • Page 24: Exact ® Micro Tests & Reagents

    For a complete list of accuracies throughout all ranges, please visit sensafe.com/photometers/spa-exact-ez/. For detailed instructions on using this product, contact us (see below) or visit sensafe.com/photometers/spa-exact-ez Combined Chlorine DPD-3 Test requires Free Chlorine DPD-1 (486637) to be run fi rst.