Santak C700 User Manual

Portable power station

Advertisement

Quick Links

USER
PORTABLE
MANUAL
POWER STATION
C700 & C1400

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C700 and is the answer not in the manual?

Questions and answers

Summary of Contents for Santak C700

  • Page 1 USER PORTABLE MANUAL POWER STATION C700 & C1400...
  • Page 3 Change history Release date Description 2024-03-15 First release. NOTE: SANTAK, STK, and CASTLE are registered trademarks of SANTAK Electronic (Shenzhen) Co., Ltd. Permission must be obtained before using them.
  • Page 4: Table Of Contents

    Contents Safety precautions ................1 Package list ................... 5 Function description ................5 Panel introduction ..................5 Introduction to the display interface ............9 Turn-on instruction ...................11 Turn-off instruction ...................11 Charge .......................11 UPS mode ....................13 Maintenance ..................14 Clean ......................14 Storage ......................14 Usage ......................14 Alarms ....................
  • Page 5: Safety Precautions

    • Use additional devices and accessories specified by our company. If you need to replace any part, check the information on SANTAK's official website www.santak.com. • Use the product within the allowed operating temperature range of -20℃ to +60℃. High ambient temperature will easily trigger the overtemperature protection function of the portable power station, limiting the load capacity or load time.
  • Page 6 Product charging • The portable power station must be charged with an officially designated charging cable. SANTAK is not responsible for any consequences caused by the use of unauthorized charging cables. • When charging, put the portable power station on the floor away from flammable or combustible materials.
  • Page 7 temperature of the battery is 0℃ to 50℃, and charging within the optimal charging ambient temperature (22℃ to 28℃) can greatly prolong the service life of the battery. Product storage and transportation • Keep the portable power station out of reach of children. •...
  • Page 8 recommended to recharge the portable power station to 30% to 80%, and then turn off the portable power station and store it at room temperature. • Avoid using alcohol and other organic solvents to clean the surface of the portable power station. Wipe the surface with a dry cotton cloth.
  • Page 9: Package List

    Package list Charge Watt OutPut Watt Charge Watt DC O/P AC O/P OutPut Watt 10~60VDC 100W 100W DC INPUT 10A MAX DC O/P AC O/P 10~30VDC DC INPUT 10A MAX SINE WAVE 220V/1400W 28W MAX 28W MAX 28W MAX DC 12V 65W MAX DC 12V AC INPUT 220V...
  • Page 10 AC INPUT 220V AC BREAKER DC OUTPUT 10A MAX �� �� �� �� �� C700 Folding handle 10 Lighting and control switch 11 USB-A port Ambient light sensor (ALS) 12 Charging input port Power switch and function settings 13 Circuit breaker...
  • Page 11 No. Item Description Press for 0.1s to 1s to: – Turn on the portable power station – Wake up the LCD backlight and ambient light – Mute when the buzzer beeps Press the button twice within 1.5s to turn off the ambient light.
  • Page 12 No. Item Description Short press the power switch to turn on or turn off the output of USB-C port (9 in the preceding DC output figure), USB-A port (11 in the preceding figure), switch and LED and car charging outlet (15 in the preceding indicator figure).
  • Page 13: Introduction To The Display Interface

    AC output vacuum cleaners. Derating is required for devices socket greater than 700 W (C700) or 1400 W (C1400) (test before use, some may not be supported). The car charger supports the maximum current output of 13.6V/10A, which can not only power...
  • Page 14 Used to set and display the ECO (energy saving) mode status. Used to set and display the UPS mode status. B Charge/Discharge time Displays the estimated remaining charge/discharge time based on the current power consumption. C Faults and alarms Temperature abnormal AC mains input abnormal Inverter output abnormal Overload...
  • Page 15: Turn-On Instruction

    G Output power Displays the current output active power or apparent power. *By default, the ECO (energy saving) mode is disabled. The portable power station will continue to output energy until the battery runs out. To enable the ECO (energy saving) mode, see the description in "Panel introduction"...
  • Page 16 (⑧) to the solar panel. This product can be charged with 10-60 VDC (C1400)/10-30 VDC (C700) input. If the input exceeds 60 V (C1400)/30 V (C700), overvoltage protection will be triggered. Overvoltage may cause damage to the product. For damage caused by exceeding the specified number of connections or not connecting according to specifications, SANTAK will not provide free repair service.
  • Page 17: Ups Mode

    SANTAK will not provide free maintenance service. Charge Watt OutPut Watt DC O/P AC O/P 10~60VDC 100W 100W DC INPUT 10A MAX SINE WAVE 220V/1400W...
  • Page 18: Maintenance

    * The UPS mode is available only for equipment below 1400 W (C1400)/700 W (C700). Do not use other equipment at the same time during use to avoid triggering the overload protection function of the mobile power storage power supplier. SANTAK is not responsible for malfunction or data loss caused by improper use.
  • Page 19: Alarms

    • Continuous operation under high ambient temperature and heavy load may trigger the overtemperature protection function of this product. In this case, wait for the temperature inside the product to recover before continuing to use it. Alarms Ambient light Item Alarm Buzzer Indication...
  • Page 20: Troubleshooting

    Ambient light Item Alarm Buzzer Indication (orange) Overtemperature √ √ Temperature Low temperature   √ Fan stuck or     disconnected √ Troubleshooting Alarm Symptom Cause Possible solution indication The AC mains is normal, but the The circuit breaker portable power of the portable Manually connect station cannot be...
  • Page 21: Technical Specifications

    If the problem persists, contact your local distributor or SANTAK Customer Service at santakexport@santak.com. Please be sure to record and provide the following information: • Model and serial number • Date of failure • Complete problem description (including indicator status, buzzer...
  • Page 22 -20℃ to +60℃ Charge temperature 0 to 50℃ Battery SoH >80% SoH after 500cycles *The maximum AC+DC output power is 1400 W (C1400)/700 W (C700). *USB-A protocol:QC2.0, QC3.0, FCP, AFC *USB-C protocol:QC2.0, QC3.0, FCP, AFC, PD3.0, PPS(3A) - 18 -...
  • Page 23: Appendix Acronyms And Abbreviations

    Appendix Acronyms and abbreviations Acronym/Abbreviation Full form Alternating current Ambient light sensor Liquid-crystal display Uninterruptible power supply - 19 -...
  • Page 24 SANTAK Electronic (Shenzhen) Co., Ltd. Address: No.8 Baoshi Road, 72 Block, Baoan District, Shenzhen, P.R.China www.santak.com 614-40200AX1-00...