rn
Installation Instructions
to the expe_
NOTE:
Read
the entire
instruction
manual
before
starting
the
installation.
NOTE:
Installer:
Make
sure the Owner's
Manual
and Service
Instructions
are left with the unit after installation.
TABLE
OF CONTENTS
PAGE
SAFETY
CONSIDERATIONS
.........................
1
INTRODUCTION
...................................
2
RECEIVING
AND INSTALLATION
.................
2-13
Check Equipment
..................................
2
Identify
Unit
....................................
2
Inspect
Shipment
.................................
2
Provide
Unit Support
...............................
2
Roof Curb
......................................
2
Slab Mount
.....................................
6
Field Fabricate
Ductwork
............................
6
Provide
Clearances
.................................
6
Rig and Place Unit
.................................
6
Inspection
......................................
6
Rigging/Lifting
..................................
6
Connect
Condensate
Drain
...........................
9
Install Flue Hood
...................................
9
Install
Gas Piping
..................................
9
Install Duct Connections
............................
10
Configuring
Units for Downflow
(Vertical)
Discharge
.....................................
10
Install Electrical
Connections
........................
11
High-Voltage
Connections
........................
11
..............
12
.......................
12
.............................
12
Heat Anticipator
Setting
..........................
12
Transformer
Protection
...........................
12
...................................
13
.....................................
13-24
Check for Refrigerant
Leaks
.........................
13
Start-Up
Heating
& Make Adjustments
................
13
...........................
14
................................
14
................................
14
.............................
15
Normal
Operation
...............................
22
Airflow
and Temperature
Rise ......................
22
Heating
Sequence
of Operation
.....................
22
Limit Switches
.................................
22
Rollout
Switch
.................................
22
Start-Up
Cooling
& Make Adjustments
................
22
Checking
Cooling
Control
Operation
................
22
Checking
& Adjusting
Refrigerant
............
22
Indoor Airflow
and Airflow
Adjustments
.............
23
Continuous
Fan Operation
........................
24
Cooling
Sequence
of Operation
.....................
24
MAINTENANCE
................................
34-38
Air Filter
......................................
34
Indoor Blower
and Motor
.........................
34
A09034
Fig. 1 - Unit 48ES-A
(Low NOx Model Available)
Induced
Draft (Combustion
Air) Blower
..............
35
Flue Gas Passageways
............................
35
Limit Switch
...................................
35
Burner
Ignition
.................................
35
...................................
35
Removal
of Gas Train
............................
36
Coil, Indoor Coil, & Condensate
Drain Pan
....
36
Outdoor
Fan
...................................
36
Electrical
Controls
and Wiring
.....................
37
Circuit
...............................
37
Gas Input ......................................
37
Evaporator
Airflow
..............................
37
Puron Items
....................................
37
TROUBLESHOOTING
..............................
38
............................
38
SAFETY
CONSIDERATIONS
Improper
installation,
adjustment,
alteration,
service
maintenance,
or
use
can
cause
explosion,
fire,
electrical
shock,
or
other
conditions
which
may
cause
death,
personal
iniury,
or property
Consult
a qualified
installer,
service
agency,
or your
distributor
or branch
for information
or assistance.
The qualified
installer
or agency
must use factory-authorized
kits or accessories
when
modifying
this product.
Refer
to the individual
instructions
packaged
with the kits or accessories
when installing.
Follow
all safety codes.
Wear safety
glasses,
protective
clothing,
and work
gloves.
Have
a fire extinguisher
available.
Read
these
thoroughly
and
follow
all warnings
or cautions
included
in literature
and
attached
to
the
unit.
Consult
local
building
codes, the current editions
of the National
Fuel Gas Code
(NFGC)
NFPA 54/ANSI
Z223.1,
and the National
Electrical
Code
(NEC)
NFPA 70.
Need help?
Do you have a question about the Comfort 48ES A Series and is the answer not in the manual?
Questions and answers