Table of Contents 1. Introduction ..................4 ................4 1.1 Key Features 1.2 Indications for Use ..............4 1.3 Explanation of Symbols ............5-6 2. Warnings and Cautions ...............6-8 3. Components ..................9 4. Cleaning ..................10 4.1 Before using your pump ............10 4.2 After using your pump ...............10 5.
Useful information or information you need to know when using NOTICE this product. 1.2 Indications for Use The Cimilre S7 Dual Pro breast pump is intended to be used by lactating women to express and collect milk from their breasts.
1.3 Explanation of Symbols Symbol Description Manufacturer Date of manufacture Serial number General prohibition sign General warning sign Caution Notice Refer to instruction manual Type BF applied part CLASS II equipment Alternating current Degree of protection against harmful ingress of water or IP22 particulate matter.
Humidity limitation Atmospheric pressure limitation Keep dry Fragile, handle with care This product should not be mixed with other commercial waste for disposal. Power(Start or stop each pump) Battery Status Adjust the level of suction Control both pumps simultaneously 3 cycle settings per level in SYNC Mode LED night light 2.
Page 6
If damage is found, immediately discontinue use of power adapter or battery pack and call Cimilre customer service. • The Cimilre S7 Dual Pro should not be positioned so that it is difficult to operate the adapter. WARNING: To avoid health risk and reduce the risk of injury.
Page 7
• This product is the intended for use by a single user only and should not be shared between users. • Do not drive while pumping. • Never use while pregnant, as pumping can induce labor. • Clean and sanitize all parts that come in contact with your breast and breast milk prior to first use.
3. Components • Cimilre reserves the right to substitute any component or accessory with a replacement of equivalent performance. Included Components 1 - Dual Motor Rechargeable Breast Pump, Cimilre S7 Dual Pro 2 - Tubing 3 - Backflow Protector Top...
4. Cleaning 4.1 Before using your pump Clean and sanitize the parts before using your pump for the first time. Backflow protectors Breast shields Bottles, bottle discs, and bottle covers Nipples Valves WARNING: Do not wash or boil tubing. Tubing needs to remain dry to avoid any potential mold contamination.
7. Screw the bottle onto the underside of the breast shield. 8. Connect the tubing to the backflow protector assembly and connect the other end of the tubing to the Cimilre S7 Dual Pro(for single pumping attach the cap on one of the airflow ports).
While some discomfort may be felt when first using a breast pump, using a breast pump should not cause pain. If you are unsure about breast shield sizing, please contact a Lactation Consultant or Cimilre representative who can help you get a proper fit.
(Same method as enabling.) Night Light - The LED light appears by pressing the cimilre logo. - LED can be adjusted with 3 dim levels. - Press the button one more time at level 3 to turn off the LED.
6.4 Battery Information Description Operating time: Approx 2+ hours When Charging - Bars flash progressively inside the battery indicator to show that the pump is charging. Fully Charged - Battery indicator shows 3 full bars and the outline of the battery blinks continuously.
When the pump is powered on for the first time after unboxing, the suction may be preset to a higher level than desired. Adjust the level to a preferred setting before first use. After first use, the Cimilre S7 Dual Pro will automatically remember your last settings for your next pumping session.
Page 15
6. To adjust the suction (vacuum) strength for each breast independently, press the SYNC control to power SYNC off ("SYNC" light in center of the screen will turn off). Then you can adjust the level of each pump by pressing the arrow control.
6.6 Suction Settings 1. The Cimilre S7 Dual Pro will automatically remember your last settings for your next pumping session. If you want to start pumping on different settings, adjust the settings before you start expressing. 2. The suction (vacuum) level refers to the suction strength; this is measured in millimeters of mercury (mmHg).
7. Breast Shield Sizing 7.1 Understanding Size Pumping should not hurt. This guide is a starting point to help determine your optimal size based on your nipple diameter. How to find the right size flange for you: Areola Step 1: Using a ruler or measuring tape, Nipple Base measure the diameter of your nipple at Nipple...
Good Fit Too Small Too Large 7.3 Determining the right fit Does your nipple rub the sides of flange tunnel to the point of causing discomfort? Do you see excessive areola being pulled into tunnel? Do you see any redness? Is your nipple or areola turning white? Do you feel unexpressed milk after pumping? If you answered ‘YES’...
8.2 How do I thaw and use stored breast milk? 1. Always thaw the oldest breast milk first. Remember first in, first out. Over time, the quality of breast milk can decrease. 2. There are several ways to thaw your breast milk: a.
No suction Check if they are Disassemble and properly properly connected to Valve reassemble. breast shield. Listen for abnormal Contact Cimilre at (888) 394- Suction pump sound/noise. 2422. level Disassemble and Defective Check the connection reassemble the kit.
10. Disposal As an electrical and electronic equipment, the device must be disposed of according to a specialized procedure for collection, pick-up and recycling or destruction in accordance with Directive 2012/19/EU of the European Council on Waste Electrical and Electronic Equipment [WEEE]. Please properly dispose the Class II medical device in accordance with local, state and federal regulations.
Guidelines and Manufacturer’s Declaration – Electromagnetic Emissions The Cimilre S7 Dual Pro is intended for use in the electromagnetic environment specified in the table below. The customer or the user of the Cimilre S7 Dual Pro should ensure that it is used in such an environment.
Page 24
0.5 cycle for 0.5 cycle interruptions environment. If the user 40% U 40% U and voltage of the Cimilre S7 Dual Pro variations (60% dip in U (60% dip in U requires continued for 6 cycles for 6 cycles...
Page 25
Conducted RF 3 Vrms 3 Vrms Portable and mobile RF communications equipment IEC 61000-4-6 150 kHz to should be used no closer to 80 MHz any part of the device, including cables, than the Radiated RF 3 V/m 3 V/m recommended separation IEC 61000-4-3 80 MHz to...
Page 26
The Cimilre S7 Dual Pro is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of Cimilre S7 Dual Pro can help prevent electromagnetic interference by maintaining a minimum distance between...
13. Description of IP Classification 0: Non-protected 1: Protected against solid foreign objects of 50 mm Ø and greater 2: Protected against solid foreign objects of 12,5 mm Ø and greater 3: Protected against solid foreign objects of 2,5 mm Ø and greater 4: Protected against solid foreign objects of 1,0 mm Ø...
14. Warranty LIMITED MANUFACTURER’S WARRANTY The manufacturer provides the following limited warranties on the Cimilre S7 Dual Pro: THE MANUFACTURER PROVIDES A LIMITED 24-MONTH MECHANICAL WARRANTY FOR MAIN PUMP: The manufacturer provides a LIMITED MECHANICAL WARRANTY that the main pump will be free from manufacturing defects in materials and workmanship under normal personal use for the 24-month period after purchase by the original owner.
Page 29
THIS IS THE EXCLUSIVE WARRANTY BY THE MANUFACTURER, WHICH DOES NOT MAKE ANY OTHER WARRANTY OF ANY KIND, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY. This breast pump is intended for single-user use only. Sharing a breast pump can cause health hazards and voids the manufacturer’s warranty.
Page 30
CIMIRLE S7 Dual Pro Operation Manual Cimilre Co., Ltd. 97-14, Seongnam-ro, Mokcheon-eup, Dongnam-gu, Cheonan-si, Chungcheongnam-do, Korea Phone : +82-41-553-0941 Email : cimilre@cimilre.kr Symmetrical Health, LLC AGENT 615 Main Street Toms River, NJ 08753 Phone: (888) 394-2422 Email: help@cimilrebreastpumps.com 2023.11.02 REV0...
Need help?
Do you have a question about the S7 Dual Pro and is the answer not in the manual?
Questions and answers