Evco EVD Web User Manual
Evco EVD Web User Manual

Evco EVD Web User Manual

Iot gateway for the epoca system
Hide thumbs Also See for EVD Web:

Advertisement

Quick Links

EVCO S.p.A.
EVD Web | User manual ver. 1.0 | Code 144DWEBE104
EVD Web
®
IoT gateway for the EPoCA
system
User manual | ENGLISH
Code 144DWEBI104
page 1 of 28

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EVD Web and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Evco EVD Web

  • Page 1 EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 EVD Web ® IoT gateway for the EPoCA system User manual | ENGLISH Code 144DWEBI104 page 1 of 28...
  • Page 2 EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 IMPORTANT Read this document carefully before installation and before using the device and take all the prescribed precautions. Keep this document with the device for future reference. Only use the device in the ways described in this document.
  • Page 3: Table Of Contents

    EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 Contents INTRODUCTION ........................................4 MAIN FEATURES OF THE MODELS AVAILABLE AND PURCHASING CODES ......................... 5 MEASUREMENTS AND INSTALLATION ..................................6 Measurements ........................................ 6 INSTALLATION ........................................ 6 DESCRIPTION ........................................... 7 ELECTRICAL CONNECTION ......................................
  • Page 4: Introduction

    Equipped with 3 RS-485 master serial ports, each for a line of up to 6 controllers with the MODBUS RTU protocol, EVD Web also has a TTL serial port to connect another EVCO controller.
  • Page 5: Main Features Of The Models Available And Purchasing Codes

    EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 MAIN FEATURES OF THE MODELS AVAILABLE AND PURCHASING CODES PURCHASING CODES EVDW01Z9 FORMAT 4 DIN modules • USER INTERFACE Blind version • INSTALLATION On a DIN rail •...
  • Page 6: Measurements And Installation

    EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 MEASUREMENTS AND INSTALLATION 3.1 Measurements Measurements are expressed in mm (inches). 3.2 INSTALLATION On a DIN rail in a control panel. To install the device, proceed as shown in figures 1 and 2.
  • Page 7: Description

    EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 DESCRIPTION PART DESCRIPTION Ethernet port Micro USB port RS-485 MODBUS master ports Power supply Reserved Analogue inputs TTL MODBUS port Signalling LED page 7 of 28...
  • Page 8: Electrical Connection

    - the compatibility of the connected controllers with the EPoCA cloud platform depends on the type of controller: see the document EPoCA - List of compatible controllers which is available on the website www.evco.it or by scanning the QR code below: 5.1 Connectors 5.2 Description of connectors...
  • Page 9 EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 DIGITAL OUTPUTS CONN. DESCRIPTION reserved reserved reserved ANALOGUE INPUTS CONN. DESCRIPTION reference (GND) analogue input 1 (for Pt 1000 probes) analogue input 2 (for Pt 1000 probes) analogue input 3 (for Pt 1000 probes) TTL MODBUS port.
  • Page 10: Main Possible Scenarios

    EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 MAIN POSSIBLE SCENARIOS 6.1 Scenario 1 ® Management via the EPoCA cloud platform of: ® up to 18 EVCO devices with EPoCA technology connected in 3 RS-485 networks:...
  • Page 11: Scenario 2

    Management via a third-party supervision system which uses MODBUS TCP of: up to 18 EVCO or third-party devices with the MODBUS RTU protocol: 6 with the same connection parameters (baud rate, parity, stop bits) connected to the first RS-485 MODBUS master port...
  • Page 12: First-Time Use

    Connect the micro USB port on EVD Web to the free USB port on the PC (or laptop) using connecting cable 0810500023. Connect the Ethernet port on EVD Web to the free Ethernet port on the router (or to the free Ethernet port of the Ethernet hub connected to the local network) using an Ethernet cable.
  • Page 13 EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 Run the EPoCA.exe app on the PC (or laptop). The Device selection screen will appear. Select the device then press Next (only click Device web page for extremely advanced configurations).
  • Page 14 EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 Check the Sync server data box to be able to send data to the EPoCA ® cloud platform. Select Save Config. to save the plant configuration data. As it is the first time the device is used, the system will suggest downloading the configuration file (hereinafter also called plant file) to the PC (or laptop).
  • Page 15 Device data recording to delete the data recorded by the connected device. This procedure is only possible if the connected device is recognised by EVD Web, namely if On Line and not Off Line appears to the right of Addr. X.
  • Page 16 Select the criterion for assigning the EVD Web IP address from the drop-down menu: Dynamic if the address is assigned automatically by a router If the router does not assign an IP address to EVD Web within 90 s, the device will automatically be allocated: IP address 192.168.4.1 subnet mask 255.255.255.0...
  • Page 17 EPoCA technology to respond to a request from EVD Web. In the Idle time box of the Modbus RTU group, enter the minimum time in milliseconds that must elapse between EVD Web receiving a response from a ® device in the RS-485 network of EVCO devices without EPoCA technology and sending the next request.
  • Page 18 EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 Once MODBUS configuration is complete, select Next. The following screen will appear. Select Configure: the EPoCA.exe app will close. page 18 of 28...
  • Page 19: First Access To The Epoca Cloud Platform

    EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 ® 7.2 First access to the EPoCA cloud platform Open the web browser on the PC (or laptop) and open the web page epoca.cloud. The following screen will appear.
  • Page 20 EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 Select REGISTER. The following screen will appear. Enter the username for the account in the Username box (see point 3). Enter the password for the account in the Password box (see point 4).
  • Page 21: Subsequent Uses

    EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 SUBSEQUENT USES 8.1 Subsequent uses of EVD Web From point 10 of section 7.1. Run the EPoCA.exe app on the PC (or laptop). The Device selection screen will appear.
  • Page 22: Subsequent Accesses To The Epoca

    EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 Enter the name for the plant in the Plant name box (see point 12, section 7.1). Enter the password for the plant in the Password box (see point 13, section 7.1).
  • Page 23: Signalling Leds

    EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 SIGNALLING LEDS FLASHING BLINKING COM0 no MODBUS activity MODBUS activity (communication status TTL MODBUS port) COM1 no MODBUS activity MODBUS activity (communication status RS-485 MODBUS master port 1)
  • Page 24: Accessories

    EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 ACCESSORIES 10.1 Connecting cable Personal Computer 0810500023 Allows connection from the device to a PC via a USB. Length: 1 m (3.28 ft). 10.2 Connection kit CJAV74 Makes it possible to cable the device.
  • Page 25: Technical Specifications

    EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 TECHNICAL SPECIFICATIONS Housing Grey, self-extinguishing Category of heat and fire resistance Measurements 4 DIN modules: 71.0 x 110.0 x 60.0 mm (2 13/16 x 4 5/16 x 2 3/8 in)
  • Page 26 EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 page 26 of 28...
  • Page 27 EVCO. The customer (manufacturer, installer or end user) assumes all responsibility for the configuration of the device. EVCO accepts no liability for any possible errors in this document and reserves the right to make any changes at any time without prejudice to the essential functional and safety features of the equipment.
  • Page 28 EVCO S.p.A. EVD Web | User manual ver. 1.0 | Code 144DWEBE104 EVCO S.p.A. Via Feltre 81, 32036 Sedico (BL) ITALY phone +39 0437 8422 fax +39 0437 83648 email info@evco.it web www.evco.it page 28 of 28...

Table of Contents