Download Print this page
Evco DADO Series Quick Start Manual
Evco DADO Series Quick Start Manual

Evco DADO Series Quick Start Manual

Internet / modbus gateway

Advertisement

Available languages

Available languages

Quick Links

EVCO S.p.A. | Code 104D2EA104 | Pag. 1 di 2| GL 10/13 | version 1.0
DADO series
Internet / MODBUS Gateway
EN
ENGLISH
EVD2ETHB30
Ethernet
DADO communicates with the CloudEvolution internet portal via Ethernet using the existing network infrastructure (on
EVD2ETHB30), Ethernet or GPRS (on EVD2ETHG30) and Ethernet or WiFi (on EVD2ETHW30).
The communication mechanism has a low data volume and it has been designed to be as much firewall-fiendly as possible.
Static IP address not requested.
DIMENSIONS
Dimensions
The dimensions are expressed in mm.
77.6
68.1
72.6
63.1
68.5
73.0
INSTALLATION
Installation
Device may only be put into service and operated by qualified personnel only.
The device is designed for an installation on a grounded 35 mm DIN Rail in dry rooms.
(only on EVD2ETHG30)
(db9 to therminal
block adapter)
After installation the housing of the device is connected with functional earth.
The power supply must be a grounded circuit (PELV) and it must be a limited power source according to
EN60950-1 cap 2.5 or the device must be provided with an antisurge fuse of 2 A.
Insert the SIM card in the device's rear before the installation on the DIN rail, The device must be switched off (only on
EVD2ETHG30). It is recommended to remove the SIM card PIN before use in the device.
Never use the device in areas where the operation of wireless equipment is prohibited. The location for the antenna
must guarantee the recommended radiological limits (be at least 20 cm from persons and other antennas). When the
antenna is installed outdoors the lightning protection standard VDE V0185 must be complied with. The EMC lightning
protection zone concept must be observed. The device must be switched off during work on the antenna. It can not be
guaranteed, that there will not be any harmful interference for other devices. In case of interferences install the device
or the antenna in another location (only for EVD2ETHG30 and EVD2ETHW30).
GETTING STARTED
Getting started
Wire the device according to the technical data.
Get the "Installation manual" at www.evco.it/eng/products/monitoring/clouevolution.html and follow instructions.
All manuals and user guides at all-guides.com
EVD2ETHG30
Ethernet / GPRS
9.5
SD card
24 VDC
Device
1
RS485
+ -
GND
IMPORTANT
Read this document thoroughly before installation and before
EVD2ETHW30
use of the device and follow all recommendations; keep this
Ethernet / WiFi
document with the device for future consultation.
Only use the device in the way described in this document.
1
1.1
GND
1.2
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Housing
2
2.1
Green LED
Yellow LED
2.2
The following chart illustrate the LEDs meaning on EVD2E-
THB30 (Ethernet):
Status A
Status B
Status C
Status D
RS485
Power
The following chart illustrate the LEDs meaning on EVD2E-
THG30 (Ethernet / GPRS):
Modem
GSM/GPRS
1= Y (+)
Status A
5= GND
Status B
6= Z (-)
Power
The following chart illustrate the LEDs meaning on EVD2E-
Device
Device
THW30 (Ethernet WiFi):
2
3
120 ohm
WLAN
Connect
Status A
Status B
Power
3
3.1
Operating Temperature
3.2
Operating Temperature
3.2
The device must be disposed of in compliance
with local standards regarding the collection of
electric and electronic equipment.
PIN ASSIGNMENT
Power supply
FE
Functional earth
Ground
VCC
24 VDC
Serial interface
RS232
NC
RxD
TxD
NC
GND
NC
RTS
CTS
NC
Connected to functional earth
LEDs
Ethernet interface
Link indication
Activity indication
LEDs meaning
LEDs on EVD2ETHB30
- - -
- - -
Serial communication (MODBUS)
MODBUS TCP communication
Device is powered
LEDs on EVD2ETHG30
Modem is initialized
GPRS internet connection status
Serial communication (MODBUS)
MODBUS TCP communication
Device is powered
LEDs on EVD2ETHW30
WLAN module is initialized
WLAN connection status
Serial communication (MODBUS)
MODBUS TCP communication
Device is powered
GENERAL DATA
General data
Size (WxLxH)
46x105x70 mm
0 bis 55 °C
Electrical shock
Class III
Protection rating
IP20
EMC emission
IEC 61000-6-4
EMC immunity
IEC 61000-6-2
Compliance
CE, RoHS
Electrical data
Supply voltage
24 VDC (±15%)
<80 mA (on EVD2ETHB30)
<120 mA (on EVD2ETHG30)
<0.10 A (on EVD2ETHW30)
Scope of supply
EVD2ETHB30 or EVD2ETHG30 or EVD2ETHW30
Start-up guide
Connector 3-pin
DB9 - Terminal Block Adapter
Male 90° GPRS antenna (EVD2ETHG30)
Male 90° WiFi antenna (EVD2ETHW30)
EVPS02
RS485
Y (+)
NC
NC
NC
GND
Z (-)
NC
NC
NC

Advertisement

loading
Need help?

Need help?

Do you have a question about the DADO Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Evco DADO Series

  • Page 1 All manuals and user guides at all-guides.com EVCO S.p.A. | Code 104D2EA104 | Pag. 1 di 2| GL 10/13 | version 1.0 DADO series Internet / MODBUS Gateway ENGLISH IMPORTANT Read this document thoroughly before installation and before EVD2ETHB30 EVD2ETHG30 EVD2ETHW30 use of the device and follow all recommendations;...
  • Page 2 Antenna maschio 90° WiFi (EVD2ETHW30) EVCO S.p.A. Questo documento è di esclusiva proprietà EVCO; EVCO non si assume alcuna responsabilità in merito ai possibili errori riportati. Il cliente (costruttore, installatore o utente finale) si assume ogni responsabilità in merito alla configurazione del dispositivo.

This manual is also suitable for:

Evd2ethb30Evd2ethg30Evd2ethw30