Piazzetta LEGNA E929 Series Instructions For Installation, Use And Maintenance Manual
Piazzetta LEGNA E929 Series Instructions For Installation, Use And Maintenance Manual

Piazzetta LEGNA E929 Series Instructions For Installation, Use And Maintenance Manual

Advertisement

Quick Links

EN
The instruction manual is an integral part of the product
Wood burning stove
Range E929
Range ROUND
INSTRUCTIONS FOR INSTALLATION,
USE AND MAINTENANCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LEGNA E929 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Piazzetta LEGNA E929 Series

  • Page 1 The instruction manual is an integral part of the product Wood burning stove Range E929 Range ROUND INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE...
  • Page 2 TRONIC FORMAT on our company website (www.piazzetta.com), under “Products”, on the specific product characteristics page. This document is the property of Gruppo Piazzetta S.p.A. and no part of it may be reproduced or disclosed to third parties, whol- ly or in part, without written permission All rights reserved by Gruppo Piazzetta S.p.A..
  • Page 3: Table Of Contents

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE CONTENTS GENERAL INFORMATION PRODUCT INFORMATION Product description Part identification Product identification data Characteristics Accessories upon request Technical data Sizes FUEL GENERAL INFORMATION REGARDING THE SYSTEM Installation room Fresh air intake Chimney Chimney terminal Flue pipe PREPARATIONS FOR INSTALLATION Handling Unpacking...
  • Page 4: General Information

    (authorized technical assistance centre). in the sections " FAULTS " or " MESSAGES - - Gruppo Piazzetta S.p.A. cannot be held liable for situations of SAFETY WARNINGS - ANOMALIES ". risk, defects, damage, product malfunctioning or for damage...
  • Page 5 INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Product use may cause some surfaces to During the operation and/or cooling phase, become extremely hot (the glass, the exter- slight creaking noises may be heard. This nal surfaces, the handles, the smoke outlet is not considered a defect, but is a conse- passage).
  • Page 6: Product Information

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE PRODUCT INFORMATION Do not use the appliance as an incinerator or in any way other than that for which it was designed. PRODUCT DESCRIPTION Do not use the appliance if the glass or seals ■...
  • Page 7: Part Identification

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE PART IDENTIFICATION Upper smoke outlet Combustion chamber Door Ceramic glass Door handle Smoke deflector (Skamolex) Upper back panel (Aluker) Left side panel (Aluker) Lower back panel (Aluker) 10 Grate 11 Ash drawer 12 Right side panel (Aluker) 13 Combustion air control 14 Metal structure 15 Cladding (example for E929 M model)
  • Page 8: Product Identification Data

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE PRODUCT IDENTIFICATION DATA CHARACTERISTICS Each product is identified in the following way: Structure: - IDENTIFICATION DATA PLATE (1) with the model (A) and ap- - in steel pliance performance specifications Cladding: - SERIAL NUMBER PLATE (2) with the serial number of the ap- - majolica pliance (B) Firebox:...
  • Page 9: Technical Data

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE TECHNICAL DATA E929 C, E929 C S/B, E929 E929 C, E929 C S/B, E929 C-H, D, E929 M, E929 T, ROUND, E929 D, E929 M, E929 T, E929 C-H S/B, E929 D, E929 Model ROUND M, ROUND-H, E929 ROUND, ROUND M, ROUND-H, D-H, E929 M, E929 M-H, E929 T,...
  • Page 10 INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE (1) Weight without HSS accumulation kit (2) Weight with HSS accumulation kit (n1) Data obtained with top outlet connection (n2) Data obtained with rear outlet connection (n4) Data obtained with top outlet connection and installation of 1 m additional connecting flue pipe. Laboratory data using beech wood with moisture content below 16%.
  • Page 11: Sizes

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE (values in cm) SIZES E929 C Fig. 4 22 30,5 27.5 Ø 15 cm 7,5 cm 7,5 cm A Smoke outlet Combustion air duct Ducting outlet standard position E929 C-H Fig. 5 16 24,5 27.5 15 cm 7,5 cm 7,5 cm Ø...
  • Page 12 INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE E929 D Fig. 6 32,5 15 cm 7.5 cm 7,5 cm Ø A Smoke outlet Combustion air duct Ducting outlet standard position E929 D-H Fig. 7 32,5 Ø 15 cm 7.5 cm 7.5 cm A Smoke outlet Combustion air duct Ducting outlet...
  • Page 13 INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE E929 M Fig. 8 32,5 15 cm 7.5 cm 7.5 cm Ø A Smoke outlet Combustion air duct Ducting outlet standard position E929 M-H Fig. 9 8 32,5 Ø 15 cm 7.5 cm 7.5 cm A Smoke outlet Combustion air duct Ducting outlet...
  • Page 14: E929 T X

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE E929 T Fig. 10 32,5 Ø 15 cm 7.5 cm 7.5 cm A Smoke outlet Combustion air duct Ducting outlet standard position ROUND Fig. 11 18,5 Ø 15 cm 7.5 cm 7.5 cm A Smoke outlet Combustion air duct Ducting outlet standard position...
  • Page 15: Round M X

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE ROUND-M Fig. 12 18,5 Ø 15 cm 7.5 cm 7.5 cm A Smoke outlet Combustion air duct Ducting outlet standard position ROUND-H Fig. 13 18,5 Ø 15 cm 7.5 cm 7.5 cm A Smoke outlet Combustion air duct Ducting outlet standard position...
  • Page 16: E929 C-H S/B

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE E929 C S/B Fig. 14 27,5 Ø 15 cm 7,5 cm A Smoke outlet Combustion air duct standard position E929 C-H S/B Fig. 15 27.5 15 cm 7,5 cm Ø A Smoke outlet Combustion air duct standard position DT2003572_H072246EN0_04...
  • Page 17: Fuel

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Unsuitable fuel FUEL Never use damp wood or wood with pitch. The following must not be used: waste (refuse), waste paper, pa- The characteristics and quality of the wood considerably affect per briquettes, plywood or chipboard, fibrous panels, packaging, product autonomy, efficiency, atmospheric emissions and correct painted wood or wood covered with synthetic material, plastic product operation.
  • Page 18: General Information Regarding The System

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE GENERAL INFORMATION The existence of more than one appliance is only per- REGARDING THE SYSTEM mitted if allowed by the regulations and manufacturer of each individual appliance. Below is some general information regarding the system, appli- If the existence of more than one appliance is permit- ■...
  • Page 19: Fresh Air Intake

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE The connecting pipe for the combustion air inlet of the appliance must comply with the following requirements: In the appliance installation room: - have a diameter equal to or greater than the diameter of the it is not permitted to install liquid fuel appliances with ■...
  • Page 20: Chimney Terminal

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE CHIMNEY TERMINAL The chimney terminal is the part which is positioned on the top of the flue to ease the dispersion of combustion products into the atmosphere. In brief, remember that the chimney terminal: - must have a useful outlet section of not less than twice that of H (*) the flue...
  • Page 21 INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE The connecting flue pipe must not cross rooms where it is prohibited to install combustion appliances, nor in other rooms divided into compartments for fire or with the hazard of fire, or in rooms and/or spaces that can- not be inspected.
  • Page 22: Preparations For Installation

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE PREPARATIONS FOR INSTALLATION Product installation and maintenance must be carried out exclusively by qualified personnel with sufficient knowledge of the product itself. This work must also be carried out using suitable equip- ■ ment and in full compliance with all health and safety regulations.
  • Page 23: Installation Kit And Accessories

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Construction elements which are already present such as wood- A Product air distance from rear wall en beams or a counter-hood and all trims in combustible material Product air distance from side walls must be positioned outside the irradiating range of the product Area free from combustible or heat-sensitive materials D Distance of front floor protection overhang and away from any grilles or slits from which hot air is releases.
  • Page 24: Combustion Air Connection

    Connection with inlet (1) air into a designated room. - connect the flexible pipe (1) to the combustion air duct (2) on In this EXCLUSIVE system PATENTED by Gruppo Piazzetta S.p.A., the appliance heat produced by the firebox is distributed from bottom-up with- - secure the flexible pipe (1) with a clamp (3) (not supplied).
  • Page 25 - remove the knockout from the rear panel of the cladding - graft the connecting flue pipe on the smoke outlet using a T25 Fig. 27 (1) pipe and a C6 curve (2) (Gruppo Piazzetta S.p.A. accessories). Depending on the model, connection with other outlets is pos- sible:...
  • Page 26: Start-Up And Operating Test

    Additional requirements for the connecting flue pipe - read the instructions and the information, supplied in all forms Gruppo Piazzetta S.p.A. supplies pipes and bends for the connect- together with the product and any accessories, as well as the ing flue pipe, all of which are approved and specifically sized for documentation referred to in this manual carefully the smoke outlet of its products.
  • Page 27: Use

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE 10 USE If any part of the appliance or the connecting flue pipe leaks smoke while the appliance is in use, refer to the section " FAULTS ". To reload fuel in the firebox, open the door, adjust the combustion air and damper valve (where applicable) or move parts of the appliance which may be hot.
  • Page 28: Starting The Appliance

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE A significant amount of unburned gas/smoke inside the firebox can cause the flame to ignite suddenly and in some cases, can cause the glass to explode. An excessive fuel load and excessive opening of the ■...
  • Page 29: Fuel Dimensions And Layout

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE In the case of climatic conditions which are not optimal for appliance operation (low pressure, windy day...) there could be an inverse draught in the flue system. In this case, use a small amount of paper to heat the flue and restore the normal draught and then proceed to start-up the appliance as normal.
  • Page 30: Operation In Adverse Climatic Conditions

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Your own experience will give you an indication of the amount of wood to be loaded and the most suitable combustion air control. In the case of fire, extinguish using a fire extinguisher. To operate the appliance at minimum, the firebox must be hot (at Do not extinguish the fire with water.
  • Page 31: Cleaning And Maintenance

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE 11.1 SCHEDULED MAINTENANCE 11 CLEANING AND MAINTENANCE Scheduled maintenance must be carried out at least For all installation and maintenance interventions ONCE A YEAR and in any case, before the commission- which require access to inside the cladding, the smoke ing of the appliance after a long period of inactivity.
  • Page 32: Cleaning The Ceramic Cladding

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE 11.4 CLEANING THE GLASS Recommended interval Interventions which may be carried out by the user During start-up it is possible that tar may accumulate on the glass which will disappear when optimal combustion is reached. If this Glass 1 day does not happen, it is recommended that the glass is cleaned dai-...
  • Page 33 INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Removing the internal parts of the firebox Proceed as follows: - open the firebox door - support the upper back panel (2) with your hand - remove the bracket (7) from the relative side panel - turn the rear part of the side (3) towards the centre of the fire- box, then tilt it and remove it from the mouth of the firebox - continue to support the upper back panel (2) and at the same...
  • Page 34: Disposal Of Ashes

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Cleaning parts in ALUKER “Aluker ® ” is a material made of non toxic substances, resistant to Recommended cleaning frequency: refer to the section heat (up to 1400°C). Despite its good mechanical resistance it is "...
  • Page 35: Faults

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Smoke escapes from the firebox in adverse weather 13 FAULTS conditions POSSIBLE CAUSES ACTION All work is to be carried out when the fire is out, the Operations which require the intervention of the T.A.C. appliance has cooled down completely and with the Smoke evacuation system ob- Check and clean the smoke...
  • Page 36 INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Condensation forms The firebox does not heat up POSSIBLE CAUSES ACTION POSSIBLE CAUSES ACTION Interventions which may be carried out by the user Interventions which may be carried out by the user Start-up procedure not suffi- Refer to the section “...
  • Page 37: Disposal Of Product At End Of Product Life

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Noisy fan (if present) 14 DISPOSAL OF PRODUCT AT END OF POSSIBLE CAUSES ACTION PRODUCT LIFE Operations which require the intervention of the T.A.C. The owner is exclusively responsible for destroying and disposing Powder or foreign bodies in Checking and cleaning the fan of the product in compliance with the regulations in force as re- the fan...
  • Page 38: Reference Standards

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE 15 REFERENCE STANDARDS Country of application: The European Union EN 13240 Roomheaters fired by solid fuel - Requirements and test methods EN 1443 Chimneys - General requirements EN 1457-1 Chimneys - Clay/ceramic flue liners - Part 1: Flue liners operation under dry conditions – Requirements and test methods EN 1457-2 Chimneys - Clay/ceramic flue liners - Part 2: Flue liners operating under wet conditions - Requirements and test...
  • Page 39: Appendix

    INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE 16 APPENDIX Identification data plate: key Please read and comply with the instructions for installation, use and maintenance. Model = Model Type = Type DoP = Declaration of performance N.Body = Notified body Pn = Nominal heat output Pp = Part load heat output Pnom = Nominal space heat output Ppart = Part load space heat output...
  • Page 40 Via Montello, 22 31011 Asolo (TV) - ITALY Tel. +39.04235271 - Fax +39.042355178 www.piazzetta.com e-mail:infopiazzetta@piazzetta.it...

Table of Contents