Brief Operating Instructions
Flowmeter
Proline 10
IO-Link transmitter
with Coriolis sensor
These instructions are Brief Operating Instructions; they are
not a substitute for the Operating Instructions pertaining to
the device.
Brief Operating Instructions part 2 of 2: Transmitter
Contain information about the transmitter.
Brief Operating Instructions part 1 of 2: Sensor →  3
Solutions
Services

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline 10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Endress+Hauser Proline 10

  • Page 1 Services KA01665D/06/EN/01.24-00 71654759 2024-06-12 Brief Operating Instructions Flowmeter Proline 10 IO-Link transmitter with Coriolis sensor These instructions are Brief Operating Instructions; they are not a substitute for the Operating Instructions pertaining to the device. Brief Operating Instructions part 2 of 2: Transmitter Contain information about the transmitter.
  • Page 2 Flowmeter Proline 10 IO-Link Order code: XXXXX-XXXXXX Ser. no.: XXXXXXXXXXXX Ext. ord. cd.: XXX.XXXX.XX Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555 Endress+Hauser...
  • Page 3 These Brief Operating Instructions are Brief Operating Instructions Part 2: Transmitter. The "Brief Operating Instructions Part 1: Sensor" are available via: • Internet: www.endress.com/deviceviewer • Smart phone/tablet: Endress+Hauser Operations App Detailed information about the device can be found in the Operating Instructions and the other documentation: • Internet: www.endress.com/deviceviewer •...
  • Page 4: Table Of Contents

    Table of contents Flowmeter Proline 10 IO-Link Table of contents About this document ............. . 5 Symbols .
  • Page 5: About This Document

    Flowmeter Proline 10 IO-Link About this document About this document Symbols 1.1.1 Warnings DANGER This symbol alerts you to an immediate dangerous situation. Failure to avoid the situation will result in a fatal or serious injury. WARNING This symbol alerts you to a potentially dangerous situation. Failure to avoid the situation may result in a fatal or serious injury.
  • Page 6: Safety Instructions

    Safety instructions Flowmeter Proline 10 IO-Link Forbidden procedures, processes or actions Additional information Reference to documentation Reference to page Reference to graphic Measure or individual action to be observed Series of steps 1. 2. ,… Result of a step Help in the event of a problem...
  • Page 7: Environment And Process

    Modifications to the device ‣ Only carry out modifications or repairs after consulting beforehand with an Endress+Hauser service organization. ‣ Install spare parts and accessories according to the Installation Instructions. ‣ Only use original spare parts and original accessories from Endress+Hauser. Endress+Hauser...
  • Page 8: Product Information

    Product information Flowmeter Proline 10 IO-Link Product information Designated use The device is intended only for the flow measurement of liquids and gases. Depending on the version ordered, the device measures potentially explosive, flammable, poisonous and oxidizing media. Devices for use in a hazardous area, in hygienic applications, or where there is an increased risk due to process pressure, are labeled accordingly on the nameplate.
  • Page 9: Product Design

    Flowmeter Proline 10 IO-Link Installation Product design The transmitter and sensor form a mechanical unit. A0043525  1 Main device components Housing cover Display module Transmitter housing Sensor Installation For detailed information about installing the sensor, see the Brief Operating Instructions for the sensor →...
  • Page 10: Turning The Transmitter Housing

    Installation Flowmeter Proline 10 IO-Link Turning the transmitter housing Order code for "Housing", option "Aluminum" Loosen the fixing screws on both sides of the transmitter housing. NOTICE Overrotation of the transmitter housing! Interior cables are damaged. ‣ Turn the transmitter housing a maximum of 180°...
  • Page 11: Post-Installation Check

    Flowmeter Proline 10 IO-Link Installation Post-installation check Is the device undamaged (visual inspection)?  Does the device comply with the measuring point specifications? For example: • Process temperature  • Process pressure • Ambient temperature • Measuring range Has the correct orientation been selected for the device? ...
  • Page 12: Electrical Connection

    Electrical connection Flowmeter Proline 10 IO-Link Electrical connection Connecting requirements 5.1.1 Notes on the electrical connection WARNING Live parts! Incorrect work performed on the electrical connections can result in an electric shock. ‣ Have electrical connection work carried out by appropriately trained specialists only.
  • Page 13: Ground Cable Requirements

    Flowmeter Proline 10 IO-Link Electrical connection Ground cable requirements Copper wire: at least 6 mm (0.0093 in Endress+Hauser...
  • Page 14: Transmitter Connection

    Electrical connection Flowmeter Proline 10 IO-Link Transmitter connection 5.4.1 Transmitter terminal connections A0053767 M12 plug for power supply (supply voltage) and signals (IO-Link) Dummy plug Outer ground terminal Pin assignment of IO-Link device plug IO-Link L– A0053891  2 M12 A-coded (IEC 61076-2-101)
  • Page 15: Removing A Cable

    Flowmeter Proline 10 IO-Link Electrical connection Removing a cable Use a flat-blade screwdriver to press down on the slot between the two terminal holes and hold. 3 (0.12) Remove the cable end from the terminal. A0029598  3 Engineering unit mm (in)
  • Page 16: Examples Of Electric Terminals

    Electrical connection Flowmeter Proline 10 IO-Link Examples of electric terminals 5.7.1 IO-Link L– L– A0055085  4 Connection example for IO-Link, only non-hazardous area Automation system (e.g. PLC) Industrial Ethernet or fieldbus IO-Link master Transmitter Endress+Hauser...
  • Page 17: Hardware Settings

    Flowmeter Proline 10 IO-Link Electrical connection Hardware settings 5.8.1 Enabling write protection Loosen the Allen key of the securing clamp. Open the housing cover counterclockwise. 3 mm 1,5 Nm (1.1 lbf ft) A0041094 Press the tab of the display module holder.
  • Page 18: Post-Connection Check

    Electrical connection Flowmeter Proline 10 IO-Link Post-connection check Is the protective earthing established correctly?  Are the device and cable undamaged (visual check)?  Do the cables meet the requirements?  Is the terminal assignment correct?  Are all the cable glands installed, firmly tightened and leak-tight? ...
  • Page 19: Operation

    App Store (iOS devices) or Google Play Store (Android devices). • Incorrect operation by unauthorized persons is prevented by means of encrypted communication and password encryption. • The Bluetooth® function can be deactivated after initial device setup. A0033202  5 QR code for free Endress+Hauser SmartBlue App Endress+Hauser...
  • Page 20: System Integration

    Enter the user name: admin Enter the initial password: serial number of the device Change the password after logging in for the first time. Forgotten your password? Contact Endress+Hauser Service. System integration For detailed information on system integration, see the Operating Instructions for the device.
  • Page 21: Switching On The Device

    Flowmeter Proline 10 IO-Link Commissioning Switching on the device ‣ Switch on the supply voltage for the device.  The local display switches from the start screen to the operational display. XXXXX Volume flow 1767.2063 Starting up... A0042938 If device startup is not successful, the device displays an error message to this effect .
  • Page 22: Commissioning The Device

    Diagnosis and troubleshooting Flowmeter Proline 10 IO-Link Commissioning the device 8.3.1 SmartBlue App Information on the SmartBlue App: Operating Instructions Connecting the SmartBlue App to the device Enable Bluetooth on the mobile handheld terminal, tablet or smartphone. Start the SmartBlue App.
  • Page 23 Flowmeter Proline 10 IO-Link Diagnosis and troubleshooting XXXXX XXXXX ṁ 3.23 kg/min F180 ³ m /min Temperature 3.23 Ʃ exceeded 23.0 °C Help A0042937 Operational display in alarm condition Diagnostic message Diagnostic behavior Diagnostic behavior with diagnostic code Short text...
  • Page 24 *71654759* 71654759 www.addresses.endress.com...