Installation & Operation Manual Swimming Pool Air Source Heat Pump Model Number : YC-007 Thank you very much for purchasing our product,please keep and read this manual carefully before you install heat pump.
Page 2
Packing List Name Qty. Remark Installation & Operation Manual Wire-controller Wire controller box and sponge pad (Will install on the heat pump shell) Wire-controller Cable (about 10m) Drain-pipe (2 m) Drain-pipe connector Rubber shock absorber Heat Pump Unit (The pipe connector has been installed on the machine) Please keep installation manual properly, and read it carefully before using.
Special reminding: if the unit would be installed where is vulnerable to lightning stroke, lightning protection measurements must be carried out. Special reminding: The unit is not suitable for using in the winter, the water reserved in the pipe network system must be drained. Content Accessories description.................4 Attention for safety..................5...
1. Accessories description Each unit produced by our factory is with the following accessories: Name Qty. Installation & Operation Manual 1 PC Guide users to install the system Wire controller 1 PC Used for the man-machine operation interface Wire controller connecting cable 1 PC Connect wired controller to heat pump unit Drain-pipe...
2. Attention for safety Range of application: 1.Power supply: 220-240V/~60Hz. 2.Environment temperature: 19.4°F〜109.4°F : 3.Working water temperature: Min. inlet water temperature 46°F,Max. outlet Water Temperature 104°F. If the system is always used beyond the available water range, please contact with manufacturer. The installation shall be done by the professional persons, to prevent leaking, electric shock, or fire ●...
When needs to be repaired, please entrust after-sale service department or a specialized ● personnel to implement. If improper repaired, it may cause unit operation failure, electric shock, fire, hurt, leaking, etc. Can not install the unit in combustible gas easy-leaking places, once the combustible gas leaks ●...
Page 7
3.2 Air source heat pump working principle 4 way valve Water inlet Condenser Water Outlet Gas-liquid Compressor separator Filter Filter Expansion valve Figure 1 (Heat energy get) =Q (Compressor consumption) +Q (Heat energy absorbed from ambient environment) 3.3 Heat pump performance curve for variable working condition Figure 2 Environment temperature (°F ) Attention pipeline anti-freezing in case the environmental temperature drops to 32°F.
4. Installation of the unit 4.1 Installation attention ● Avoid installations in such locations with mineral oil. ● Avoid installation in locations where air contains salt or other corrosive gas. ● Avoid installation in locations with serious power supply voltage fluctuation. ●...
Page 9
4.3 Installation space Keep the following indicated space for operation and maintenance first before installation Figure 3 Horizontal type installation space(units: mm) 4.4 Heat pump unit size Figure 4 Horizontal type heat pump size...
Size(mm) Model No. YC-007 1011 4.5 Reserve the installation base for the heat pump Please refer to Figure 5. A n c h o r b o lt Anchor bolt Screw nut/washer Drainage tray Heat Pump Heat Pump Shock absorb...
Page 11
5.1 Attention ● Prevent air, dust and other sundries from going into the water pipes. ● Fix the whole system before install the water pipes. ● Water inlet and outlet pipes shall be protected by the insulation layer. ● Stable water velocity shall be ensured, so that excessive throttling can be avoid. ●...
Page 12
Outlet DN50 DN50 YC-007 The swimming pool heat pump adopt the titanium heat ex-changer, can connect the swimming pool directly, but must install a water filtration equipment before water go into heat pump, the filter meshes is about 40 meshes.
5.2.4 The demanded quality of water ● The bad quality water will produce more scale and sand, so this kind of water should be filtered and demineralized. ● The water quality should be analyzed before system running, to measure the PH value, conductivity, Chloride ion concentration and sulphate ion concentration.
Page 14
7. Installation of electric devices 7.1 Electrical wiring ● The unit should use a dedicated power supply, power supply voltage with rated voltage. ● Unit power supply circuit must be ground, power supply wire and external grounding reliable connection, and the external grounding is effective. ●...
Page 15
7.2 Electrical Wiring Specification Model Electrical Wiring Specification 2*2.5 mm²+1*1mm² YC-007 Terminal The terminal can connect the wire max. is 4 mm² Figure 13 7.3 Circulation pump installation The heat pump only provide the signal for circulation pump, must use an a.c. Contactor to connect the circulation pump.
8. Instruction of operation 8.1 Control system specifications 8.1.1 Operating condition ● Voltage: 220V~±10%,60Hz ● Ambient temperature:19.4~109.4℉ 8.1.2 Main function ● Three operation mode: heating,cooling and constant temperature mode. ● Display the pool temperature and setting temperature, and also can query the coil temperature, ambient temperature and exhaust temperature and so on.
Page 18
8.2.1 Controller Instruction symbol status meaning Constantly bright heat pump is on Extinguished Heat pump is off Constantly bright at cooling mode Constantly bright at heating mode Constantly bright need repair Constantly bright at AUTO mode Extinguished Currently in the manual set temperature state Constantly bright this unit is a water connection heat pump Extinguished...
Page 19
Constantly bright current outlet water temperature Constantly bright current inlet water temperature Display actual water temperature, set water temperature and display fault code Constantly bright Currently showing Celsius temperature display Show real time display Timer function is on display Currently in the on-time working hours Flashing set start time for working time display...
Page 20
down 1. Press at main interface to set the temperature. 2. Press and hold for 3 seconds in the power on/off state to enter the query state. 3. In the query status, click to status query 4. Under parameter setting state, click parameter to modify 1.
Page 21
“ ”+“ ”+“ Within 5 minutes after power-on, press and hold for 5 seconds to restore the factory parameter settings. ”+“ ” 8.2.3 Operation Instruction 1)Turn ON/OFF the heat pump When the controller is in the normal display state, press “ ”...
Page 22
4)Real time clock settings: In the main interface, click the “ ” button to enter the real-time clock setting interface; In the real-time clock interface, press the “ ” button, the hour part of the number flashes, press “∧” or “∨”, you can Set the hour of the clock;...
Page 23
7) Forced speed heating: When following conditions are met at the same time: the controller is in the normal display state and heat pump is in the power-on state. Heat pump needs to be in the working period after the timing control is enabled. The current heating mode is met and the temperature condition for continuing heating is satisfied, No other alarms that do not allow "speed heating"...
Page 24
untimed return time period throughout the day. If the start time of a certain working period is greater than the end time, the end time is considered to be the next day. The factory default return water time is as follows: A, time period 1 opening time: 6:30 B, time period 1 closing time: 7:30 C, time period 2 opening time: 18:30...
Page 25
When the controller is in the normal display state, the button is locked when there is no button operation for more than 60 seconds. Press any button at this time to unlock. 8.2.4 Control Output 1) Water temperature control Normal water temperature control can be performed when the controller is turned on. Heating mode: When the water tank (inlet water) temperature ≤...
Page 26
seconds, the compressor immediately stops running. At this time, the controller displays the high pressure fault alarm code “03E”. If the high pressure switch is restored, error code will not occur. And if no other protection or locking occurs, the compressor is restarted after 3 minutes. If high pressure fault protection appears 3 times within 1 hour, the controller will lock the protection, and the compressor will be locked in the shutdown protection state.
Page 27
When the return water temperature sensor fails, the return pump is allowed to run (do not judge the return water temperature) When the water tank or ambient temperature sensor are faulty, electric heating operation is not allowed. “11E”, “12E”, “13E” ", "14E", "15E", "17E", "18E", "19E". are correspondingly displayed when the coil temperature sensor, ambient temperature sensor, exhaust temperature sensor, inlet water temperature sensor/tank temperature sensor, absorb temperature sensor, and outlet water temperature sensor/return water temperature sensor are faulty.
9. Adjusting and Initial operation 9.1 Attention ● Within 12 hours after running, please connect the circuit breaker, and make the crankcase heater be pre-heated. ● Open the valve of water system, and the valve of assistant tank, inject water into the system, and exhaust air inside.
10. Operation and maintenance 10.1 Personals shall possess professional knowledge or operate according to professionals from our company. To ensure the well functioning, the system shall be checked and maintained after a period of time. During the maintenance, please pay attention to some points below: ●...
Page 30
● Exhaust the refrigerant from the low pressure end, attention to reduce the exhaust speed, and avoid frozen oil leakage. ● Remove the compressor air suction and exhausting pipe. ● Remove the compressor power cables. ● Remove the compressor fixing screws. ●...