User Manual KI6102 / T6102 series PON Power Meter Warranty: Information in this manual is given in good faith for the benefit of the user. It cannot be used as the basis for claims against Kingfisher/Tempo or its representatives if accidental damage or inconvenience results from use or attempted repair of the equipment.
2. The Instrument Optical ports Rubber holster Figure 1: Front view Revision 11 Date: 24 Jan 2024 Page 4 of 12...
Page 5
OLT Port ONT Port ONT Port: for 1310nm upstream signal test. OLT Port: 1490/1550 nm downstream signal test. Figure 2: Top View USB connector: Connects instrument to a computer. Charging Hole: Not use Figure 3: Side View Revision 11 Date: 24 Jan 2024 Page 5 of 12...
3. Operation Instructions 3.1 ON/OFF Instrument Press and hold [ON] to turn on instrument; the Home Display below will be seen on screen as shown below. The instrument is now ready for measurements. Powers levels of the respective wavelengths will be displayed automatically when live fibers are appropriately connected to the OLN &...
3.3 Back Light Backlight turns on when instrument is turned on and goes off after 30 sec. When the backlight is off, press any key to turn it back on for another 30 sec. 3.4 Selecting Measurement Unit At Home Display, press [F2] to select measurement unit (dBm or W). 3.5 Relative Measurement Mode At Home Display, press and hold [▼] to enter Relative Measurement mode;...
Use [▲, ▼] to change value of selected digit and [▼] to change the sign (positive or negative) of a set value. Set the 3 displayed thresholds types (see below) with the desired values: ALARM (displayed as “ ! ”) PASS (displayed as “...
Choose a threshold group number (from the available 01, 02, 03) using [▲, ▼]. Press [OK] to activate Pass/Fail display mode. Press and hold [OK] to de-activate Pass/Fail display mode. 3.8 Setting Time At Home Display, press and hold [►] to enter Time Setting mode. Use [◄, ►] to select digit to be edited;...
To read retrieve/read saved data: At Home Display, press and hold [◄] to enter Data Browsing mode, see picture below. Selected test data record number Indicates Data Browsing mode Use [▲, ▼] to choose test data record saved in instrument’s memory. The chosen test data record is displayed with date, record number and time information.
4. Maintenance 4.1 Keep the sensors’ surfaces clean and free of dust or other contaminant by cleaning them regularly. 4. 2 Do not use unclean or nonstandard adapters. 4.3 Change adapter carefully if necessary and keep any spare adapter in dirt/dust free environment.
5. Content of Packing Description Quantity 6102-APC 6102AA-APC External power supply/charger PON Power meter User manual Soft carry pouch SC/APC--SC/APC or SC/PC--SC/PC Patchcord Software CD USB cable Cleaning cotton stick pack 6. Safety Take appropriate eye-safe precautions when handling live fibre. Avoid condensation The instrument is resistant to normal dust and moisture however, it is not waterproof.