Advertisement

Available languages

Available languages

R32
ENGLISH
OWNER'S MANUAL
AIR CONDITIONER (SPLIT TYPE)
For general public use
Indoor unit
42TVAB010A, 013A, 028A, 030A Series
Outdoor unit
38TVAB010A, 013A, 028A, 030A-I
1126250238

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 42TVAB010A Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier 42TVAB010A Series

  • Page 1 ENGLISH OWNER’S MANUAL AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit 42TVAB010A, 013A, 028A, 030A Series Outdoor unit 38TVAB010A, 013A, 028A, 030A-I 1126250238...
  • Page 2 PRECAUTIONS FOR SAFETY Read the precautions in this manual carefully before This appliance is with R32. operating the unit. Warning indications on the air conditioner unit Warning indication Description CAUTION CAUTION BURST HAZARD BURST HAZARD Open the service valves Open the service valves before the operation, before the operation, otherwise there might be otherwise there might be the burst.
  • Page 3 PRECAUTIONS FOR SAFETY CAUTION...
  • Page 4 INDOOR UNIT DISPLAY REMOTE CONTROLLER 1 Wi-Fi access 1 Infrared signal emitter 2 ECO 3 PURE 4 imer 5 Operation mode follow procedure on 9. " PREPARATION BEFORE USE MODE MENU Preparing Filters 1. Open the air inlet grille and remove the air SWING EXIT 2.
  • Page 5 Silent Operation Setting MENU SETUP 1. Press MENU button for enter menu setting and press TEMP. button to For select more setting of Air conditioner such as Silent operation, select Silent. Hi POWER, OFF Timer and other use MENU button Blink both triangle and feature mark Feature not yet set.
  • Page 6 Hi-P 8.4 TIMER OFF OPERATION 8.2 Hi POWER OPERATION To set the timer OFF when the air conditioner is operating. To automatically control room temperature and airflow for faster cooling operation (except in DRY and FAN ONLY mode). 1. Press MENU button for enter menu setting and press TEMP. button to select TIMER OFF.
  • Page 7 4. Confirm POWER-SEL level by press MENU button. 8.5 PURE (IONIZER) OPERATION Capture effi ciency of fl oating impurities in the air is accelerated by Ionizer Blink only triangle contaminates such as bacteria, odor, smoke, dust and virus are caught and Feature already set.
  • Page 8 TEMPORARY OPERATION OPERATION AND PERFORMANCE 1. Three-minute protection feature: To prevent the unit from being activated In case of the misplaced or discharged remote controller for 3 minutes when suddenly restarted or switched to ON. Pressing the RESET button, the unit can start 2.
  • Page 9 Android : Version 5.0 or later. About Carrier In The Air 1. Carrier In The Air can control AC operation by Smartphone or tablet (mobile device) via internet connection. 2. Everywhere control, control software run on Cloud system and mobile device can set and monitor AC operation via internet connection.
  • Page 10 Enter user name and Login successful. select Log in. password. Add Wireless adapter for control by Carrier In The Air application. Wireless adapter Built-in Active Wireless adapter by remote controller and Auto login. Select “Add AC (Adapter)” from both display above.
  • Page 11 Add Wireless adapter for control by Carrier In The Air application. AC (adapter) connect Active Wireless adapter by Remote controller Press and hold MODE button 5 seconds Wireless LED mark will blink when AP mode active WPS mode Connect with Home Wi-Fi Router...
  • Page 12 Carrier In The Air application Home screen Weekly schedule Setting Menu Add AC Sub menu all AC All AC On/Off Add Group Delete Group Group AC On/Off Operation Setting Each AC On/Off Sub menu group Select AC Change Name Operation Setting...
  • Page 13 Mode and Condition setting. Enter operation mode of All AC Enter operation mode of Group AC Enter operation mode of each AC Mode select for Carrier In The Air application. Provide for 5 operation modes Auto Cool Heat* Fan only * This “Heat mode”...
  • Page 14 Setting in operation mode. Tab for select AC Weekly schedule OFF-ON timer set 0.5-12hrs. Mode select OFF-ON Timer set Temperature set Indoor temperature Outdoor temperature ON timer set from Off mode only Fan speed set Louver set Special feature Off mode...
  • Page 15 Group operation. Maximum 3 groups 1 Group maximum = 16 units. Add group Add AC in group Delete AC in group Please make sure Factory Reset is performed before deleting AC from mobile application. button on remote controller for 5 second and active dL...
  • Page 16 Weekly schedule set. Day select Monday - Sunday Weekly schedule of all AC unit Weekly schedule of all AC unit Time select Weekly schedule set for each unit Mode select Select program for active by tick at select box Weekly schedule cancel. Weekly schedule not set Weekly schedule...
  • Page 17 Energy monitoring Select Room for Energy monitoring Select Energy monitoring Energy monitoring display Set cost calculate and currency Select Energy monitoring display Export data and send by Email The power consumption displayed is just an estimate as it is calculated simply. It may sometimes differ from the result measured by the power meter.
  • Page 18 In case of have some problem can check from Help menu. Note : Contact dealer and/or service center when equipment is malfunction.
  • Page 19 CAUTION BURST HAZARD Open the service valves before the operation, otherwise there might be the burst.
  • Page 22 Wi-Fi PURE MODE MENU SWING EXIT AUTO, LOW , LOW+ , MED MED+ , HIGH Quiet AUTO, LOW , LOW+ , MED MED+ , HIGH Quiet...
  • Page 23 SILENT#1 SILENT#2 None "by 4...
  • Page 24 Hi-P...
  • Page 25 °C °C °C 100% 100%...
  • Page 26 -10°C ~ 46°C 21°C ~ 32°C -10°C ~ 46°C 17°C ~ 32°C...
  • Page 27 Carrier In The Air t s g...
  • Page 29 Wi-Fi...
  • Page 40 1126250238...
  • Page 41 ENGLISH ภาษาไทย OWNER’S MANUAL AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit 42TVAB010, 013, 018, 024, 028, 030, 033 Series Outdoor unit 38TVAB010, 013, 018, 024, 028, 030, 033-I 1126250230...
  • Page 42: Precautions For Safety

    PRECAUTIONS FOR SAFETY Read the precautions in this manual carefully before This appliance is filled with R32. operating the unit. Warning indications on the air conditioner unit ■ Warning indication Description CAUTION CAUTION BURST HAZARD BURST HAZARD Open the service valves before the operation, Open the service valves otherwise there might be the burst. before the operation, otherwise there might be the burst. ● Keep this manual where the operator can easily find it. ● Read the precautions in this manual carefully before operating the unit. ● This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons. ● The precautions described herein are classified as DANGER, WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail.
  • Page 43 PRECAUTIONS FOR SAFETY ● This appliance is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. ● The air conditioner must be installed, maintained, repaired and removed by a qualified installer or qualified service person. When any of these jobs is to be done, ask a qualified installer or qualified service person to do them for you. ● Children should be supervised to ensure that they do not play with the appliance. ● Do not use any refrigerant different from the one specified (R32) for complement or replacement. Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to your body. ● Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. ● The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater). ● Be aware that refrigerants may not contain an odour. ● Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat, flames, sparks, or other sources or ignition. Else, it may explode and cause injury or death. ● Appliance and pipe-work shall be installed, operated and stored in a room with a floor area larger than A How to get A : A = (M / (2.5 x 0.22759 x h M is the refrigerant charge amount in appliance in kg, h is the installation height of the appliance in m: 0.6 m for floor standing/1.8 m for wall mounted/1.0 m for window mounted/2.2 m for ceiling mounted.
  • Page 44 INDOOR UNIT DISPLAY REMOTE CONTROL 1 Wi-Fi access Infrared signal emitter 2 ECO Start/Stop button 3 PURE Mode select button 4 Timer Temperature button 5 Operation mode Fan speed button Menu select button Set louver Up-Down button Set louver Left-Right button Display brightness can be adjusted, follow procedure on 9. Require Wireless LAN connecting adapter which available as accessory. Check button* *Check button under battery cover PREPARATION BEFORE USE Preparing Filters 1. Open the air inlet grille and remove the air filters. 2. Attach the filters. (see detail in the Installation Manual). Loading Batteries (when use wireless operation.) 1. Remove the slide cover. 2. Insert 2 new batteries (AAA type) following the (+) and (–) positions. Remote Control Reset 1. Remove the batteries.
  • Page 45 MENU SETUP 8.1 LOUVER SWING and HADA CARE FLOW OPERATION Comfortable air flow can select from feature. For select more setting of Air conditioner such as Louver select Hi Power, OFF Timer and other use MENU button Louver swing opearation: ● To distribute air flow in both vertical and horizontal by swing the louver automatically. HADA care flow operation: ● Air flow upward to the ceiling, provide Indirect air flow to body and homogenize room temperature. Note: ● During HADA CARE FLOW mode, FIX button cannot active. Louver Swing and HADA Care Flow Operation Setting 1. Press MENU button for enter menu selection During triangle mark blink can select menu by press TEMP. button.
  • Page 46 Hi-P 8.2 SILENT OPERATION (Outdoor Unit) 8.3 Hi POWER OPERATION To automatically control room temperature and airflow for faster cooling Keep outdoor unit operating silently to ensure either yourself or neighborhood operation (except in DRY and FAN ONLY mode) will have a tight sleep in nighttime. By this feature, the cooling capacity will be optimized to deliver such silent experience. The silent operation can be 1. Press MENU button for enter menu setting and press TEMP. button to selected from one of two purposes (Silent 1 and Silent 2). select Hi POWER There are three setting parameters: Standard level > Silent 1 > Silent 2 Silent 1: Blink both triangle and ● Though operating silently, the Cooling capacity is still prioritized to ensure feature mark Feature not having sufficient comfort inside the room. yet set ● This setting is a perfect balance between the Cooling capacity and the Sound level of outdoor unit. 2. Confirm selected feature by press MENU button again. Silent 2: ● Compromising the Cooling capacity to the Sound level in any circumstance where the outdoor unit’s sound level is highly prioritized. Blink only triangle Feature ● This setting has a purpose to reduce the maximum sound level of outdoor already set unit.
  • Page 47 PURE 8.5 TIMER OFF OPERATION 8.6 PLASMA ION OPERATION To set the timer OFF when the air conditioner is operating. Capture efficiency of floating impurities in the air is accelerated by plasma ion contaminates such as bacteria, odor, smoke, dust and virus are caught and 1. Press MENU button for enter menu setting and press TEMP. button to deactivated by Plasma Ion. select TIMER OFF. 1. Press MENU button for enter menu setting and press TEMP. button to select PURE Blink both triangle and feature mark Feature not Blink both triangle and yet set feature mark Feature not yet set 2. Enter TIMER set by press MENU button. 2. Confirm selected feature by press MENU button again. triangle mark will stop blink and setting feature will be blink instead. Blink only triangle Feature already set 3. Leave from menu setting display by select EXIT. 3. Select TIMER OFF by press TEMP. button. Can select TIMER OFF from 0.5 - 12hrs. Note: ● Plasma Ion operation dose not remove harmful substances from cigarette smoke (carbon monoxide etc.). Open a window occasionally for ventilation. 4. Confirm TIMER OFF by press MENU button. 8.7 POWER-SELECTION OPERATION Blink only triangle This function is used when the circuit breaker is shared with other electrical Feature already set...
  • Page 48: Maintenance

    DISPLAY LAMP BRIGHTNESS ADJUSTMENT REMOTE CONTROL A-B SELECTION To decrease the display lamp brightness or turn it off. To separate using of remote control for each indoor unit in case of 2 air conditioners are installed nearly. 1. Press and hold for 3 seconds until brightness level ( Remote Control B Setup. or ) is shown on remote control LCD then release the button. 1. Press RESET button on the indoor unit to turn the air conditioner ON. 2. Point the remote control at the indoor unit. 2. Press or to adjust brightness in 4 levels. Rise 3. Push and hold button on the back side of Remote Control “00” will be Decrease shown on the display. (Picture 1 ) Remote control Operation display Brightness 4. Press during pushing . “B” will show on the display and “00” will disappear and the air conditioner will turn OFF. The Remote Control B is memorized. (Picture 2 ) 100% Note: 1. Repeat above step to reset Remote Control to be A.
  • Page 49 ข้ อ ควรระวั ง เพื ่ อ ความปลอดภั ย โปรดอ่ า นคำ า เตื อ นในคู ่ ม ื อ นี ้ อุ ป กรณ์ น ี ้ เ ติ ม ด้ ว ยสารทำ า ความเย็ น R32 อย่ า งละเอี ย ดก่ อ นการใช้ ง าน สั...
  • Page 50 ข้ อ ควรระวั ง เพื ่ อ ความปลอดภั ย • เด็ ก ที ่ ม ี อ ายุ ต ั ้ ง แต่ 8 ปี ข ึ ้ น ไป และบุ ค คลที ่ ม ี ส ภาพร่ า งกาย การรั บ รู ้ หรื อ สภาพจิ ต ใจไม่ ป กติ หรื อ ขาดความรู...
  • Page 51 ข้ อ ควรระวั ง เพื ่ อ ความปลอดภั ย ข้ อ ควรระวั ง • ห้ า มล้ า งอุ ป กรณ์ ด ้ ว ยนำ ้ า เพราะอาจทำ า ให้ ไ ฟฟ้ า ช็ อ ต • ห้ า มใช้ เ ครื ่ อ งปรั บ อากาศเพื ่ อ จุ ด ประสงค์ อ ื ่ น เช่ น การถนอมอาหาร และเลี ้ ย งสั ต ว์ •...
  • Page 52 รี โ มทคอนโทรล การแสดงผลบนตั ว เครื ่ อ งปรั บ อากาศ การเข้ า ถึ ง Wi-Fi ตั ว ส่ ง สั ญ ญาณอิ น ฟราเรด โหมด ปุ ่ ม เปิ ด -ปิ ด โหมด PURE ปุ ่ ม เลื อ กโหมดทำ า งาน ตั...
  • Page 53 การตั ้ ง ค่ า เมนู 8.1 โหมดการส่ า ยใบปรั บ ทิ ศ ทางลมและโหมด H.DA สำ า หรั บ เลื อ กการตั ้ ง ค่ า อื ่ น ๆ ของเครื ่ อ งปรั บ อากาศ เช่ น ปรั บ เกล็ ด ช่ อ งลม การตั ้ ง ค่ า โหมด ปรั...
  • Page 54 Hi-P 8.2 โหมดการทำ า งานไร้ เ สี ย ง (ตั ว เครื ่ อ งภายนอก) 8.3 โหมดเย็ น เร็ ว เปิ ด ใช้ โ หมดนี ้ เ พื ่ อ ควบคุ ม อุ ณ หภู ม ิ ห ้ อ งและกระแสลมอั ต โนมั ต ิ เ พื ่ อ ทำ า ให้ ห ้ อ งเย็ น เร็ ว ขึ ้ น โหมดการทำ...
  • Page 55 PURE 8.6 โหมดฟอกอากาศด้ ว ยประจุ พ ลาสม่ า ไอออน 8.5 โหมดการทำ า งานตั ้ ง เวลาปิ ด เพิ ่ ม ประสิ ท ธิ ภ าพการดั ก จั บ สิ ่ ง สกปรกที ่ ป ะปนอยู ่ ใ นอากาศด้ ว ยประจุ พ ลาสม่ า ไอออน ตั ว ประจุ พ ลาสม่ า ตั...
  • Page 56 การเลื อ กรี โ มท โหมด การปรั บ ตั ้ ง ความสว่ า งหลอดไฟแสดงผล ในการลดความสว่ า งของหลอดไฟแสดงผลหรื อ ปิ ด การแสดงผล สำ า หรั บ แยกการใช้ ร ี โ มทคอลโทรลควบคุ ม การทำ า งานเครื ่ อ งปรั บ อากาศแต่ ล ะตั ว ในกรณี ท ี ่ ต ิ ด เครื...
  • Page 60 1126250230...
  • Page 61 ENGLISH OWNER’S MANUAL ภาษาไทย 6/8/20 9:24 AM AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit 42TVAB036 Outdoor unit 38TVAB036 1126050201...
  • Page 62: Precautions For Safety

    PRECAUTIONS FOR SAFETY Read the precautions in this manual carefully before This appliance is fi lled with R32. operating the unit. ● Keep this manual where the operator can easily fi nd it. ● Read the precautions in this manual carefully before operating the unit. ●...
  • Page 63 PRECAUTIONS FOR SAFETY ● Do not use any refrigerant different from the one specifi ed (R32) for complement or replacement. Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to your body.
  • Page 64: Remote Control

    INDOOR UNIT DISPLAY REMOTE CONTROL 1 Infrared signal emitter 1 Wi-Fi access (White) 2 Memory and Preset button ( 2 ECO (White) 3 Start/Stop button ( 3 PURE (White) 4 Mode select button ( 4 Timer (White) 5 Air fl ow button ( 5 Operation mode 6 Plasma Ion button ( - Cool and dry (Blue)
  • Page 65 Silent 2: ECO OPERATION Compromising the Cooling capacity to the Sound level in any circumstance where the outdoor unit’s sound level is highly prioritized. This setting has a purpose to reduce the maximum sound level of outdoor To automatically control room temperature to save energy (except in DRY and FAN ONLY mode) unit by 4 dB(A).
  • Page 66 AUTO RESTART FUNCTION SETTING MAINTENANCE This product is designed so that, after a power failure, it can restart Firstly, turn off the circuit breaker. automatically in the same operating mode as before the power failure. Indoor Unit and Remote Control Information ●...
  • Page 67 Edit Weekly timer program 5. Press to select desired operation. To edit the program after confi rming the weekly timer setting, follow steps 1 - 3 below. 1. Press 6. Press to select desired ● The day of the week and the program number of temperature.
  • Page 68 ข อ ควรระวั ง เพอความปลอดภั ย โปรดอ า นข อ ควรระวั ง ในคู  ม ื อ นี ้ อุ ป กรณ น ี ้ เ ติ ม ด ว ยสารทํ า ความเย็ น อย า งละเอี ย ดก อ นการใช ง าน •...
  • Page 69 ข อ ควรระวั ง เพอความปลอดภั ย • เครื ่ อ งปรั บ อากาศนี ้ ต  อ งได ร ั บ การติ ด ตั ้ ง บํ า รุ ง รั ก ษา ซ อ มแซม และ เคลื ่ อ นย า ยโดยผู  ต ิ ด ตั...
  • Page 70 หน า จอแสดงผลของตั ว เครองภายในห อ ง การทํ า งานของรี โ มทคอนโทรล ตั ว ส ง สั ญ ญาณอิ น ฟราเรด การเชอมต อ Wi-Fi (สี ข าว) ปุ  ม ตั ้ ง ความจํ า และตั ้ ง เครองล ว งหน า ( โหมด...
  • Page 71 หมายเหตุ : ระบบประหยั ด พลั ง งาน • ขณะทํ า งานในโหมดไร เ สี ย ง สมรรถนะการทํ า ความร อ น (หรื อ ทํ า ความเย็ น ) อาจลดลง หากต อ งการควบคุ ม อุ ณ หภู ม ิ ห  อ งโดยอั ต โนมั ต ิ เ พอประหยั ด พลั ง งาน (ยกเว...
  • Page 72 การตั ้ ง ค า ฟ ง ก ช ั น การเริ ่ ม การทํ า งานใหม อ ั ต โนมั ต ิ การบํ า รุ ง รั ก ษา ผลิ ต ภั ณ ฑ น ี ้ ไ ด ร ั บ การออกแบบเพอว า หากมี ไ ฟดั บ เครองจะสามารถเริ ่ ม การทํ า งานใหม อ ี ก ครั ้ ง ใน ปิ...
  • Page 73 โปรแกรมการตั ้ ง ค า นาฬกาจั บ เวลาแบบสั ป ดาห * การป ด นาฬกาจั บ เวลา จะใช ง านเพอหยุ ด การทํ า งานของเครองปรั บ อากาศเท า นั ้ น เพอที ่ จ ะตั ้ ง ค า โปรแกรมหลั ง จากการยื น ยั น การตั ้ ง ค า นาฬกาจั บ เวลา หน...
  • Page 74 MEMO...
  • Page 76 1126050201...

Table of Contents