Advertisement

Available languages

Available languages

Quick Links

ENGLISH
ภาษาไทย
OWNER'S MANUAL
AIR CONDITIONER (SPLIT TYPE)
For general public use
Indoor unit
42TVAB010, 013, 018, 024, 028, 030, 033 Series
Outdoor unit
38TVAB010, 013, 018, 024, 028, 030, 033-I
1126250230
www.ttair.co.th | Tel : 02-385-0728 | E-mail : sales@ttair.co.th | LINE ID : @ttair

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 38TVAB010-I

  • Page 1 ENGLISH ภาษาไทย OWNER’S MANUAL AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit 42TVAB010, 013, 018, 024, 028, 030, 033 Series Outdoor unit 38TVAB010, 013, 018, 024, 028, 030, 033-I 1126250230 www.ttair.co.th | Tel : 02-385-0728 | E-mail : sales@ttair.co.th | LINE ID : @ttair...
  • Page 2: Precautions For Safety

    PRECAUTIONS FOR SAFETY Read the precautions in this manual carefully before This appliance is filled with R32. operating the unit. Warning indications on the air conditioner unit ■ Warning indication Description CAUTION CAUTION BURST HAZARD BURST HAZARD Open the service valves before the operation, Open the service valves otherwise there might be the burst. before the operation, otherwise there might be the burst. ● Keep this manual where the operator can easily find it. ● Read the precautions in this manual carefully before operating the unit. ● This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons. ● The precautions described herein are classified as DANGER, WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail.
  • Page 3 PRECAUTIONS FOR SAFETY ● This appliance is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. ● The air conditioner must be installed, maintained, repaired and removed by a qualified installer or qualified service person. When any of these jobs is to be done, ask a qualified installer or qualified service person to do them for you. ● Children should be supervised to ensure that they do not play with the appliance. ● Do not use any refrigerant different from the one specified (R32) for complement or replacement. Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to your body. ● Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. ● The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater). ● Be aware that refrigerants may not contain an odour. ● Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat, flames, sparks, or other sources or ignition. Else, it may explode and cause injury or death. ● Appliance and pipe-work shall be installed, operated and stored in a room with a floor area larger than A How to get A : A = (M / (2.5 x 0.22759 x h M is the refrigerant charge amount in appliance in kg, h is the installation height of the appliance in m: 0.6 m for floor standing/1.8 m for wall mounted/1.0 m for window mounted/2.2 m for ceiling mounted.
  • Page 4: Remote Control

    INDOOR UNIT DISPLAY REMOTE CONTROL 1 Wi-Fi access Infrared signal emitter 2 ECO Start/Stop button 3 PURE Mode select button 4 Timer Temperature button 5 Operation mode Fan speed button Menu select button Set louver Up-Down button Set louver Left-Right button Display brightness can be adjusted, follow procedure on 9. Require Wireless LAN connecting adapter which available as accessory. Check button* *Check button under battery cover PREPARATION BEFORE USE Preparing Filters 1. Open the air inlet grille and remove the air filters. 2. Attach the filters. (see detail in the Installation Manual). Loading Batteries (when use wireless operation.) 1. Remove the slide cover. 2. Insert 2 new batteries (AAA type) following the (+) and (–) positions. Remote Control Reset 1. Remove the batteries.
  • Page 5: Menu Setup

    MENU SETUP 8.1 LOUVER SWING and HADA CARE FLOW OPERATION Comfortable air flow can select from feature. For select more setting of Air conditioner such as Louver select Hi Power, OFF Timer and other use MENU button Louver swing opearation: ● To distribute air flow in both vertical and horizontal by swing the louver automatically. HADA care flow operation: ● Air flow upward to the ceiling, provide Indirect air flow to body and homogenize room temperature. Note: ● During HADA CARE FLOW mode, FIX button cannot active. Louver Swing and HADA Care Flow Operation Setting 1. Press MENU button for enter menu selection During triangle mark blink can select menu by press TEMP. button.
  • Page 6: Hi Power Operation

    Hi-P 8.2 SILENT OPERATION (Outdoor Unit) 8.3 Hi POWER OPERATION To automatically control room temperature and airflow for faster cooling Keep outdoor unit operating silently to ensure either yourself or neighborhood operation (except in DRY and FAN ONLY mode) will have a tight sleep in nighttime. By this feature, the cooling capacity will be optimized to deliver such silent experience. The silent operation can be 1. Press MENU button for enter menu setting and press TEMP. button to selected from one of two purposes (Silent 1 and Silent 2). select Hi POWER There are three setting parameters: Standard level > Silent 1 > Silent 2 Silent 1: Blink both triangle and ● Though operating silently, the Cooling capacity is still prioritized to ensure feature mark Feature not having sufficient comfort inside the room. yet set ● This setting is a perfect balance between the Cooling capacity and the Sound level of outdoor unit. 2. Confirm selected feature by press MENU button again. Silent 2: ● Compromising the Cooling capacity to the Sound level in any circumstance where the outdoor unit’s sound level is highly prioritized. Blink only triangle Feature ● This setting has a purpose to reduce the maximum sound level of outdoor already set unit.
  • Page 7: Power-Selection Operation

    PURE 8.5 TIMER OFF OPERATION 8.6 PLASMA ION OPERATION To set the timer OFF when the air conditioner is operating. Capture efficiency of floating impurities in the air is accelerated by plasma ion contaminates such as bacteria, odor, smoke, dust and virus are caught and 1. Press MENU button for enter menu setting and press TEMP. button to deactivated by Plasma Ion. select TIMER OFF. 1. Press MENU button for enter menu setting and press TEMP. button to select PURE Blink both triangle and feature mark Feature not Blink both triangle and yet set feature mark Feature not yet set 2. Enter TIMER set by press MENU button. 2. Confirm selected feature by press MENU button again. triangle mark will stop blink and setting feature will be blink instead. Blink only triangle Feature already set 3. Leave from menu setting display by select EXIT. 3. Select TIMER OFF by press TEMP. button. Can select TIMER OFF from 0.5 - 12hrs. Note: ● Plasma Ion operation dose not remove harmful substances from cigarette smoke (carbon monoxide etc.). Open a window occasionally for ventilation. 4. Confirm TIMER OFF by press MENU button. 8.7 POWER-SELECTION OPERATION Blink only triangle This function is used when the circuit breaker is shared with other electrical Feature already set...
  • Page 8: Temporary Operation

    DISPLAY LAMP BRIGHTNESS ADJUSTMENT REMOTE CONTROL A-B SELECTION To decrease the display lamp brightness or turn it off. To separate using of remote control for each indoor unit in case of 2 air conditioners are installed nearly. 1. Press and hold for 3 seconds until brightness level ( Remote Control B Setup. or ) is shown on remote control LCD then release the button. 1. Press RESET button on the indoor unit to turn the air conditioner ON. 2. Point the remote control at the indoor unit. 2. Press or to adjust brightness in 4 levels. Rise 3. Push and hold button on the back side of Remote Control “00” will be Decrease shown on the display. (Picture 1 ) Remote control Operation display Brightness 4. Press during pushing . “B” will show on the display and “00” will disappear and the air conditioner will turn OFF. The Remote Control B is memorized. (Picture 2 ) 100% Note: 1. Repeat above step to reset Remote Control to be A.
  • Page 9 ข้ อ ควรระวั ง เพื ่ อ ความปลอดภั ย โปรดอ่ า นคำ า เตื อ นในคู ่ ม ื อ นี ้ อุ ป กรณ์ น ี ้ เ ติ ม ด้ ว ยสารทำ า ความเย็ น R32 อย่ า งละเอี ย ดก่ อ นการใช้ ง าน สั...
  • Page 10 ข้ อ ควรระวั ง เพื ่ อ ความปลอดภั ย • เด็ ก ที ่ ม ี อ ายุ ต ั ้ ง แต่ 8 ปี ข ึ ้ น ไป และบุ ค คลที ่ ม ี ส ภาพร่ า งกาย การรั บ รู ้ หรื อ สภาพจิ ต ใจไม่ ป กติ หรื อ ขาดความรู...
  • Page 11 ข้ อ ควรระวั ง เพื ่ อ ความปลอดภั ย ข้ อ ควรระวั ง • ห้ า มล้ า งอุ ป กรณ์ ด ้ ว ยนำ ้ า เพราะอาจทำ า ให้ ไ ฟฟ้ า ช็ อ ต • ห้ า มใช้ เ ครื ่ อ งปรั บ อากาศเพื ่ อ จุ ด ประสงค์ อ ื ่ น เช่ น การถนอมอาหาร และเลี ้ ย งสั ต ว์ •...
  • Page 12 รี โ มทคอนโทรล การแสดงผลบนตั ว เครื ่ อ งปรั บ อากาศ การเข้ า ถึ ง Wi-Fi ตั ว ส่ ง สั ญ ญาณอิ น ฟราเรด โหมด ปุ ่ ม เปิ ด -ปิ ด โหมด PURE ปุ ่ ม เลื อ กโหมดทำ า งาน ตั...
  • Page 13 การตั ้ ง ค่ า เมนู 8.1 โหมดการส่ า ยใบปรั บ ทิ ศ ทางลมและโหมด H.DA สำ า หรั บ เลื อ กการตั ้ ง ค่ า อื ่ น ๆ ของเครื ่ อ งปรั บ อากาศ เช่ น ปรั บ เกล็ ด ช่ อ งลม การตั ้ ง ค่ า โหมด ปรั...
  • Page 14 Hi-P 8.2 โหมดการทำ า งานไร้ เ สี ย ง (ตั ว เครื ่ อ งภายนอก) 8.3 โหมดเย็ น เร็ ว เปิ ด ใช้ โ หมดนี ้ เ พื ่ อ ควบคุ ม อุ ณ หภู ม ิ ห ้ อ งและกระแสลมอั ต โนมั ต ิ เ พื ่ อ ทำ า ให้ ห ้ อ งเย็ น เร็ ว ขึ ้ น โหมดการทำ...
  • Page 15: Power-Selection

    PURE 8.6 โหมดฟอกอากาศด้ ว ยประจุ พ ลาสม่ า ไอออน 8.5 โหมดการทำ า งานตั ้ ง เวลาปิ ด เพิ ่ ม ประสิ ท ธิ ภ าพการดั ก จั บ สิ ่ ง สกปรกที ่ ป ะปนอยู ่ ใ นอากาศด้ ว ยประจุ พ ลาสม่ า ไอออน ตั ว ประจุ พ ลาสม่ า ตั...
  • Page 16: Auto Restart

    การเลื อ กรี โ มท โหมด การปรั บ ตั ้ ง ความสว่ า งหลอดไฟแสดงผล ในการลดความสว่ า งของหลอดไฟแสดงผลหรื อ ปิ ด การแสดงผล สำ า หรั บ แยกการใช้ ร ี โ มทคอลโทรลควบคุ ม การทำ า งานเครื ่ อ งปรั บ อากาศแต่ ล ะตั ว ในกรณี ท ี ่ ต ิ ด เครื...
  • Page 17 1126250230 www.ttair.co.th | Tel : 02-385-0728 | E-mail : sales@ttair.co.th | LINE ID : @ttair...

Table of Contents