Ecler VEO-XCTRLG2 User Manual
Ecler VEO-XCTRLG2 User Manual

Ecler VEO-XCTRLG2 User Manual

Video distribution over ip h.265 full hd over ip video extender controller
Hide thumbs Also See for VEO-XCTRLG2:

Advertisement

Quick Links

VEO-XCTRLG2
VIDEO DISTRIBUTION OVER IP
H.265 Full HD over IP Video Extender Controller
USER MANUAL
50-0434-0104
VEO-XCTRLG2
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VEO-XCTRLG2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ecler VEO-XCTRLG2

  • Page 1 VEO-XCTRLG2 VIDEO DISTRIBUTION OVER IP H.265 Full HD over IP Video Extender Controller USER MANUAL 50-0434-0104 VEO-XCTRLG2...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PRECAUTIONS ........................3 1.1 Important Remark ..........................3 1.2 Important Safety Instructions ......................4 1.3 Cleaning ..............................4 PACKAGE CONTENTS ......................5 DESCRIPTION AND FEATURES ..................5 3.1 Main Features ............................6 INSTALL & CONNECT ......................7 4.1 Rack Mounting in VEO-RK1CG2 .....................
  • Page 3: Precautions

    1. PRECAUTIONS 1.1 IMPORTANT REMARK The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
  • Page 4: Important Safety Instructions

    1.2 IMPORTANT SAFETY INSTRUCTIONS Read these instructions. 12. Unplug the device during lightening sorts or when unused for long periods Keep these instructions. of time. Heed all warnings. Refer servicing qualified Follow all instructions. personnel. Servicing is required when Do not use this device near water. the device has been damaged in any Clean only with dry cloth.
  • Page 5: Package Contents

    • 3. DESCRIPTION AND FEATURES VEO-XCTRLG2 is a controller module that allows the user to manage and operate VEO- XTI1CG2 and VEO-XRI1CG2 video over IP devices in large multipoint to multipoint systems. It mounts two dedicated LAN ports to host independent Control and Video networks.
  • Page 6: Main Features

    3.1 MAIN FEATURES Easy to create project, control and manage the system. • Setup wizard to easy assign devices to a project including Auto, DHCP and Manual • IP configurations. HTTPS, SSH, SFTP security compatible. • Built-in Web GUI control interface, supporting Drag & Drop operations and VideoWall •...
  • Page 7: Install & Connect

    4. INSTALL & CONNECT 4.1 RACK MOUNTING IN VEO-RK1CG2 This product can be mounted in a VEO-RK1CG2 3U rack accessory (Please contact your supplier for 4U rack sale). The mounting steps are as follows: 1. Use included screws to fix two mounting ears on the product, as shown in the figure below: 2.
  • Page 8: Connection Diagram

    IT staff how to properly set the Multicast products connected to the local network switch. One of the advantages in the use of VEO-XCTRLG2 is the possibility to separate the Video Network to the Control Network. In this way, the consistent multicast traffic generated by the video over IP extenders can be isolated from the control traffic generated by the embedded or by the third-party control system.
  • Page 9: Web Connection And Settings

    4.3.1 WEB CONNECTION AND SETTINGS. If there is no DHCP server in the system, the default IP addresses of VEO-XCTRLG2 for Control LAN Port is 192.168.6.100 and for its Video LAN Port is 169.254.8.100. VEO-XTI1CG2 and VEO-XRI1CG2 must be set in the same network range as VEO- XCTRLG2 VIDEO LAN Port in order to be able to configure and manage all the system.
  • Page 10: Wizard Setup

    4.4.2 WIZARD SETUP Once logged in, if there’s no existing project, this message will appear to help the user to configure the system through the wizard procedure. Then click Next to advance to the next page. If the system has already been configured previously, clicking “Close” will take the user directly to the system control page.
  • Page 11 It will then be possible to decide whether to add all the connected devices to the new project (brand new installation) or to add them selectively in case of changes to an existing system. 1. If you select “Automatically add Transmitters and Receivers to system” and click the “Next”...
  • Page 12 2. If the second option is selected “List all discovered Transmitters and Receivers.” in the wizard windows and click the “Next” button to enter the Project page. Then all the connected devices will be listed in the Unassigned Devices and the “Add All”...
  • Page 13 A pop-up warning will show up when changing to DHCP mode There will be no need to set up the Video LAN port settings of the VEO-XCTRLG2 controller box in Auto or DHCP as they will be automatically configured by the controller.
  • Page 14 4.4.2.3 STATIC IP MODE BY MANUAL SETTINGS 1. Select the static IP mode by manually settings option, to manually enter the IP address. 2. Press Next and then manually set the IP address, subnet mask and gateway of the Video LAN and then press Next. It’s strongly recommended to use different IP network domain from Control LAN port.
  • Page 15: Start-Up And Operation

    5. START-UP and OPERATION 5.1 WEB FUNCTIONS AND OPERATION After setting up VEO-XCTRLG2 and assigning the VEO-XTI1CG2 and VEO-XRI1CG2 devices connected to the network to a given project, the following menus of the web settings page will let the user manage and operate different aspects and functionalities concerning Transmitter and Receiver operation as explained in the next chapters.
  • Page 16 5.1.1.1 ENCODERS (TRANSMITTERS) This page allows to setup the current Transmitter as required. ID: The ID of the current device. (Note: ID is never duplicated.) Name: The name of the current device. (Note: Name can’t never be duplicated.). MAC Address: The MAC Address of the current device. IP Address: The IP Address of the current device.
  • Page 17 Basic settings: Name: The name of the current device. (Note: Name can’t never be duplicated.). Change ID: The ID of the current device. (Note: ID is never duplicated.) Show Front Panel: This parameter selects the status of the Front Panel 7 segments LEDs: ON: The LEDs stay permanently ON.
  • Page 18 Network settings: 1. IP Mode: The configuration defining how IP addresses are assigned in a network (STATIC/ DHCP). 2. Subnet Mask: A mask used to separate the part of the IP address that identifies the network and the part that identifies devices on that network. 3.
  • Page 19 5.1.1.2 DECODERS (RECEIVERS) On this page, the user can setup the current Receiver as required. ID: The ID of the current device. (Note: ID is not duplicated.). Name: The name of the current device. (Note: Name is not duplicated.). MAC: The MAC Address of the current device. IP: The IP Address of the current device.
  • Page 20 A. Basic settings: Name: The name of the current device. (Note: Name can’t never be duplicated.). Source: The signal source (Transmitter) of the current device. Change ID: The ID of the current device. (Note: ID is never duplicated.) Front Panel Buttons: This parameter lets the user enable and disable the front panel buttons.
  • Page 21 A/V Settings: Video Output: This parameter tuns off the HDMI output. Video Pause: This parameter freezes the las frame shown. No Video Case: This parameter is a Timeout After Video Lost and it will turn off HDMI output when there’s no video signal detected after the chosen time period (minutes).
  • Page 22 (IP / RS232 command in, to RS-232 out). This will allow third party control systems the ability to send an RS-232 or IP command to the VEO-XCTRLG2 and a RS-232 command to be sent out of a Receiver or a Transmitter as a result.
  • Page 23: Matrix

    OFF: a static fixed routing for distributing two-way RS-232 commands between a • set of Transmitters and all the associated Receivers that have Fixed Routing configured. So, this serial connection allows point to point, point to multipoint and multipoint to multipoint serial bidirectional transmitting scenarios. When Serial Guest Mode is disabled, Locked Signal Routing is enabled.
  • Page 24: Videowall

    5.1.3 VIDEOWALL This section is divided in two pages. In each one, allows the user to create and manage the listed video walls and the source selected in the videowall. 5.1.3.1 VIDEOWALL LIST On this page, the user can create and configure videowall as required. •...
  • Page 25 Select the video wall that you want to configure on the “Video Wall List”, then click “Assign Receiver” to enter the Receiver assignment page. Click each screen to select the corresponding Receiver device, then click “Apply”. A Receiver can only be assigned to one videowall. When a group of receivers is assigned to a video wall, they are removed from the matrix section.
  • Page 26 Click “Class Preset” to enter the class configuration page, then click each screen to select the corresponding Class as required (the same class name will form a video wall and a regular or irregular video wall can be created by Class Configuration).
  • Page 27 Click “Border Adjustment” to enter the adjustment configuration of each display. This allows the user to adjust the width and the height of the display. 5.1.3.2 VIDEO WALL SOURCE This page allows to select different videowalls and class preset configurations that have been set up on the “Video Wall List”...
  • Page 28: Users

    5.1.4 USERS On this page, new user accounts can be added. The controller web GUI can be setup with different users each with their own control privileges. This will allow the user to create a unique login and feature settings such as inputs and outputs that each person has access Click “Create”...
  • Page 29: Controller Settings

    5.1.5 CONTROLLER SETTINGS On this page, the user can configure communication and network settings for the control and video LAN networks as required. A. System Configurations: 1. Click “Save Project” to save the project file (config_file.json), so that you can use the saved project next time without scanning devices again.
  • Page 30 GPIO manual configuration allowing a user to write its own scripted routines. D. Control Network: This section allows the user to set the network configuration and DHCP parameters for the VEO-XCTRLG2 “Control LAN” port. Click “Apply” to keep the changes.
  • Page 31: Tcp Command List

    To make use of TCP 3rd party remote control, it is necessary to enter current IP address of VEO-XCTRLG2 and TELNET port configured to access the device. To access to telnet the user must write “telnet [controller IP]”. Then, to visualize the data of all the devices connected to the controller, execute "get status”.
  • Page 32 STATIC IP [ip address] Set the encoder static ip address. ip address = [xxx.xxx.xxx.xxx] • STATIC GATEWAY [gateway ip] Set the encoder static gateway address. gateway ip=[xxx.xxx.xxx.xxx] • STATIC MASK [subnetmask] Set the encoder static subnet mask subnetmask = [xxx.xxx.xxx.xxx] address.
  • Page 33 STREAM BITRATE [rate] Set the encoder stream encoding bitrate. rate = • [0:1Mb 1:4Mb 2:8Mb 3:16Mb 4:20Mb] AUDIO FORMAT [PCM or AAC] Set the encoder audio encoding format PCM or AAC. Set the encoder EDID copy from decoder. EDID COPY [dec] EDID DEFAULT [edid] Set the encoder Default EDID.
  • Page 34 ON/OFF Set the decoder output ON or OFF. OSD ON/OFF Set the decoder output to show ID OSD or hide ID OSD. OSD ON 90 Set the decoder output show ID OSD timeout in 90 seconds. OSD COLOR [co] Set the decoder output OSD color. co = •...
  • Page 35 Video wall control Command Variable Description CREATE WALL Create video wall. HANDLE [hdl] DELETE WALL Delete video wall. HANDLE [hdl] NAME [name] Set the video wall name. name: max 16 characters • C [c] R [r] Set the video wall columns and rows . SET WALL [hdl] c=[01...09]: Number of columns in •...
  • Page 36 Device management Command Variable Description Search all encoders and decoders. SEARCH RESET Reset search encoders and decoders. GET SEARCH STATUS Get the search status. Add new encoder devices. ENC [enc] ADD DEV [dev] Add new decoder devices. DEC [dec] • dev=[01...n]: Search list index value RESET...
  • Page 37: Firmware Update

    5.1.7 FIRMWARE UPDATE On this page, the user can separately update the firmware of any Transmitter/Receiver by clicking the corresponding “Update” button on the right or update all the firmware of Transmitter/Receiver simultaneously by clicking the corresponding “Update All” button. There is also the possibility to upload the User EDID1 and User EDID2 by clicking the “Upload User EDID1”...
  • Page 38: Password Update

    5.1.8 PASSWORD UPDATE This page allows to change the password. Please note that after changing, it will skip to the Web browser home page or the Web GUI login interface automatically. You need to log in the Web GUI again with the new password.
  • Page 39: Panel Functions

    6. PANEL FUNCTIONS 6.1 FRONT PANEL RESET Button: Press and hold this button (about 10 seconds) until Status LED starts flashing: the controller will be reset automatically. POWER LED: The red LED will light on when the controller is powered on. STATUS LED: The status LED will flash in yellow-green every 1 second until the controller boots up is complete and Control LAN is ready, then it becomes solid green.
  • Page 40: Technical Data

    7. TECHNICAL DATA 7.1 TECHNICAL SPECIFICATIONS VEO-XCTRLG2 DEVICE CONTROL Control Connectors RJ-45, Euroblock, Jack 3.5mm Control Protocols Web, TCP, RS-232 Status Indicators Power LED (Red), Status LED (Green) PASS-THROUGH CONTROL Pass-through Connectors Euroblock, Jack 3.5mm Pass-through Protocols RS-232 NETWORK Network Connectors...
  • Page 41: Mechanical Diagram

    7.2 MECHANICAL DIAGRAM...
  • Page 42 NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications. For technical queries contact your supplier, distributor or complete the contact form on our website, Support / Technical requests. Motors, 166‐168 -08038 Barcelona ‐ Spain‐(+34) 932238403 information@ecler.com www.ecler.com...

This manual is also suitable for:

Veo-xti1cg2Veo-xri1cg2