MICRO CONTROL 2D Measuring System for Precisely Measuring the Dimensions and Shapes of Thin and Flat Objects PITSID Polygraphische innovative Technik Leipzig GmbH Mommsenstraße 2 | D-04329 Leipzig Tel +49 341 25942-0 | Fax +49 341 25942-99 info@pitsidleipzig.com | www.pitsidleipzig.com...
Page 2
Index General Information 1.1 Symbols 2 Intended Use and Restrictions on Use 3 Safety Instructions 4 Technical Data 5 Measuring Principle 6 The Measuring System 6.1 Scope of Delivery 6.2 Operation and Control Elements, Connections 6.3 Sensor 7 Operation 7.1 Software Installation 7.2 Calibration Procedures 7.2.1 Basic Settings 7.2.2 Distortion Correction...
7.2.7 Restore These operating instructions support you during the initial start-up, operation and 7.3 Measure maintenance of the 2D Measuring System MICRO CONTROL. 7.3.1 Saved Results It contains important information, the observance of which ensures safe use. 7.3.2 X and Y Measurement Familiarize yourself with this documentation carefully before using the measuring system to avoid personal injury and material damage.
Page 4
Intended Use and Restrictions on Use Technical Data Determinable dimensions Parallelism The 2D Measuring System MICRO CONTROL was developed for the precise measurement Straightness of primarily thin, flat objects. Even extremely thin objects, such as paper or card- Angle board, can be measured with the system.
Page 5
PointArea mented by information elements: 6.3 Sensor Fig. 1. The 2D Measuring System MICRO CONTROL consisting of a Smartphone, Measurement tools The sensor used for the measurements is the high-resolution digital camera and the PointArea integrated into the smartphone. The measurement tools and PointArea must also be used for measurements with the MICRO CONTROL.
Page 6
All measurement tools must first be integrated into the system and their parallax 7.2.2 Distortion Correction errors must be calibrated against the measuring system. The utilities required for this You can access the distortion correction from the main menu via Calibrations/ can be found under Calibrations/Measurement tools.
Page 7
Discard End Stops If your PointArea does not have an end stop or is not calibrated, please carry out the "Calibrate A to B" calibration. Resets the coordinate system of the PointArea to its original settings. To do this, press "Start". The end stops can then be redefined with Calibrate End Stops.
Page 8
The following improvement options are available to you: IMPORTANT Point 0 must be closer to the x-axis than point 1! 1 Tool Improve Vector Angle. Two measurements. Requires a calibrated Y-axis end stop. For each of the following measurements, the detection frame in the Measure a measurement tool twice at least 3 cm apart at the Y-axis end stop.
▬ Position your holding device at a different position on the PointArea and weigh guided measurements, which are only possible once several measured values it down. have been captured according to a specific sequence. ▬ ▬ Repeat the repositioning process and the three measurements at least five Each measuring mode uses a small graphic to visualise the respective measuring more times.
7.3.5 Angle Measurement 7.3.12 Rectangle Against End Stop You can determine the angle of an object to be measured with four contact points The rectangle measurement provides you with the width, height, perimeter and area (two contact points per angle segment). The contact points should preferably be at of a rectangle with two contact points, which is positioned against a calibrated end the ends of the angle segments.
▬ Type=4, circle measurement Displays all previously saved length measurement values in a Values: diameter in µm; area A in mm*mm; circumference in µm; other, diagram (requires length measurements). undocumented values ▬ Displays all previously saved XY values in an XY diagram Type=5, angle measurement (requires XY measurements).
Page 12
▬ This measuring system therefore enables you to determine the mean values and Comment 1: An XY measurement uncertainty of ± 20 µm was assumed. ▬ standard deviations of measurement series. Calibrations can be repeated and Comment 2: These specifications are only valid if it is possible to measure a 90° improved.
Maintenance 9.2 Cleaning The PointArea should be cleaned when dirty using a soft cloth and standard, non-aggressive cleaning agents. 9.1 Lithium-Ion Polymer Rechargeable Battery The smartphone and its sensors in particular should also be cleaned when dirty. The measuring system is equipped with a lithium-ion polymer rechargeable battery. When doing so, please note: These batteries are low-maintenance and have a long service life with appropriate use.
Disposal PITSID Polygraphische innovative Technik Leipzig GmbH will assume responsibility for the disposal of old MICRO CONTROL measuring system devices sent in. If you dispose of the device yourself, you must also comply with the applicable safety regulations for the disposal of lithium-ion polymer batteries.