  • Page 1 Installation instructions and how to use and look after your built-in cooker hoods NEFF (UK) Ltd...
  • Page 2 Fig. 1 Abb. 1 ELECTRO mind. mind.
  • Page 3: Appliance Description

    Light / fan interlocking, etc. switches If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.
  • Page 4: Before Using For The First Time

    Use carefully. They contain important you may find descriptions of individual information concerning your personal features that do not apply to your safety as well as on use and care of the specific appliance. appliance. This extractor hood complies with all Please retain the operating and relevant safety regulations.
  • Page 5: Safety Instructions

    Never operate the extractor hood without a grease filter. Overheated fat or oil can easily catch fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended. Never allow children to play with the appliance.
  • Page 6: Operating Procedure

    finishing cooking. The fans in this appliance can be switched to the desired setting by hand (manual mode) or can be controlled fully automatically with the automatic function according to your requirements (automatic mode).
  • Page 7 Intensive setting: 1. To switch on the intensive setting ç press the button. The fan runs for 5 minutes at Setting then switches off for 55 minutes. This process is repeated every hour. Switching off: Automatic mode has been switched Press the button.
  • Page 8 Fan run-on cannot be set if automatic mode has already been switched back to setting As long as the dot on the display flashes, fan run-on is active. After 10 minutes the fan switches off and the displays go out.
  • Page 9: Filters And Maintenance

    Important: By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up of heat such as occurs when deep-fat frying or roasting is taking place, is reduced. Saturation indicator: When the grease filters reach saturation...
  • Page 10 The activated carbon filter should risk of fire and the function of the extractor be replaced straight away. hood may be impaired. Important: Replacing the activated carbon filter: Change the activated carbon filter promptly...
  • Page 11: Cleaning And Care

    Cleaning and care Isolate the extractor hood by pulling out Stainless steel surfaces: the mains plug or switching off the fuse. Use a mild non-abrasive stainless steel cleaner. Do not clean the extractor hood with Clean the surface in the same direction abrasive sponges or with cleaning agents as it has been ground and polished.
  • Page 12: Replacing The Light Bulbs

    Disconnect the extractor hood from the 3. Replace the halogen light bulb mains electricity supply by pulling out the (conventional halogen bulb, 12 Volt, plug or switching it off at the main fuse max. 20 Watt, G4 cap). box. Caution: Refer for plug-in lampholder.
  • Page 13: Installation Instructions

    Ensure that the wall is capable of provi- ding a firm hold for mounting screws and plugs. Weight in kg: Exhaust air Recirculating air 25,0 26,5 We reserve the right to construction changes within the context of technical development.
  • Page 14 flue that is interlocking, etc. currently used for other purposes, nor into a shaft that is used for ventilating rooms in If the air intake is inadequate, there is a which stoves or fireplaces are also located.
  • Page 15 Connecting a l 150 mm exhaust-air pipe: Short, smooth air exhaust pipe. Mount the pipe As few bends in the pipe as possible. directly onto the Diameter of pipe to be as large as air outlet on the possible and no tight bends in pipe.
  • Page 16: Electrical Connection

    Electrical connection Changing over from exhaust- air to recirculating mode If you fit your own plug, the colours of Changing the electronic control system these wires may not correspond with the identifying marks on the plug terminals. to recirculating mode:...
  • Page 17: Installation

    4. Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling. Insert plugs into the holes so that they are flush with the wall.
  • Page 18 Installation 08. Screw in the two lower hexagon head 13. Push both sections of the flue panelling cap screws. together (slots in the upper section must be pointing downwards) and Before the 4 screws are tightened insert into the opening in the extractor down, align the extractor hood properly.