  • Page 1 Guardian BBU Annunciator Installation Guide Long Island City, NY, 11101 https://toweriq.nyc © 2021 TowerIQ, Inc. Document 5403501 Rev A 11/23...
  • Page 2: Specifications

    Connect [Power +] and [Power –] terminals to 12-24VDC power source UL listed for the application (TowerIQ Guardian BBU or similar). 400mA are required. Use [+ AUX –] terminals of Guardian BBU. Carefully observe polarity, damage may occur.
  • Page 3 power-limited Fig 1 AC Fail Charger Low Bat AC Power Fail AC Power Low Battery(<30%) Chrgr Charging Circuit Battery Low Component Fail CMP Fail Ground Fault RF Emitter Charger Fail Component Donor Antenna Disconnect GND Fault Ground Donor Antenna Malfunction Comm Fault Sys Cmpnt Fail...
  • Page 4 GUARDIAN ANNUNCIATOR LED DIAGNOSTICS: Decription AC Power Fail Green: AC power normal, Red: AC power failure or brownout. Battery Low Green: Battery normal. Red: Battery is missing or discharged below 30% capacity. Charger Fail Green: Charger operates normally. Red: Charger failure. Green: No critical component failure detected.
  • Page 5 GUARDIAN ANNUNCIATOR TERMINAL IDENTIFICATION OUTPUTS: Terminal Legend Function/Description AC Fail Form”C” relay output. 1A/28V, 0.6 power factor. EOL C NC NO Relay is normally energized. Reports AC failure to FACP (Fig. 1m, pg. 3) Batt Fail Form”C” relay output. 1A/28V, 0.6 power factor. EOL C NC NO Relay is normally energized.
  • Page 6 TOWERIQ GUARDIAN ANNUNCIATOR CONNECTIONS TO THE GUARDIAN BBU POWER SUPPLY: See Guardian BBU Power Supply Installation Guide 5403500 Rev. A for more information. Use [AUX +/–] terminals of Guardian BBU power supply to connect to power terminals of Guardian Annunciator. Any other 12-24V UL listed UL864 compliant power source can be used.
  • Page 7 Fig 2 Guardian Annunciator GUARDIAN BBU ANNUNCIATOR • 5403501 REV A • 11.23...
  • Page 8 ENCLOSURE DIMENSIONS (H X W X D APPROXIMATE): Fig 3 11.8” X 9.84” X 5.9” (300MM X 250MM X 150MM) 9.84” (250mm) 5.9” (150mm) 1/4 Turn Lock 2.18” 3” 4.66” (55.4mm) (76.2mm) (118.4mm) 8.27” (210mm) 0.4” (10mm) GUARDIAN BBU ANNUNCIATOR • 5403501 REV A • 11.23...