■ Ratings
Rated supply voltage (See notes 1 and 2.) 100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz), 24 VAC/VDC (50/60 Hz), 48 VDC,
Operating voltage range
No-voltage input (See note 3.)
Power consumption
Control outputs
Note: 1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model.
2. Do not use an inverter output as the power supply. Refer to Power Supplies in Safety Precautions for All Timers on page 51 for details.
3. For contact input, use contacts which can adequately switch 1 mA at 5 V.
■ Characteristics
± 0.2% FS max. ( ± 0.2% FS ± 10 ms max. in ranges of 0.6 and 1.2 s)
Accuracy of operating
time
± 5% FS ± 50 ms max.
Setting error
Operation start voltage
30% max. of rated voltage
± 0.2% FS max. ( ± 0.2% FS ± 10 ms max. in ranges of 0.6 and 1.2 s)
Influence of voltage
Influence of temperature ± 1% FS max. ( ± 1% FS ± 10 ms max. in ranges of 0.6 and 1.2 s)
100 M Ω min. (at 500 VDC)
Insulation resistance
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
Impulse withstand
3 kV (between power terminals) for 100 to 120 VAC, 200 to 240 VAC, 100 to 125 VDC;
voltage
1 kV for 24 VAC/DC, 48 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 120 VAC, 200 to
240 VAC, 100 to 125 VDC;
1.5 kV for 24 VAC/DC, 48 VDC
± 1.5 kV (between power terminals) and ± 600 V (between input terminals), square-wave noise by noise simulator
Noise immunity
(pulse width: 100 ns/1 µ s, 1-ns rise); ± 1 kV (between power terminals) for 48 VDC
Static immunity
Malfunction: 8 kV, Destruction:15 kV
Vibration resistance
Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions
Shock resistance
Destruction: 980 m/s
Malfunction: 98 m/s
Ambient temperature
Operating:
Storage:
Ambient humidity
Operating:
Life expectancy
Mechanical: 10 million operations min. (under no load at 1,200 operations/h)
Electrical:
EMC
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900 ± 5 MHz) (level 3)
Immunity Conducted Disturbance: IEC61000-4-6:
Immunity Burst:
Immunity Surge:
Case color
Light Gray (Munsell 5Y7/1)
Degree of protection
IP40 (panel surface)
Weight
Approx. 120 g
Note: Refer to the Life-test Curve.
100 to 125 VDC
85% to 110% of rated supply voltage
1 k Ω max.
ON-impedance:
ON residual voltage: 1 V max.
500 k Ω min.
OFF impedance:
100 to 120 VAC: approx. 0.23 VA (0.22 W) at 120 VAC
200 to 240 VAC: approx. 0.35 VA (0.3 W) at 240 VAC
24 VAC/DC:
approx. 0.17 VA (0.15 W) at 24 VAC
approx. 0.1 W at 24 VDC
48 VDC:
approx. 0.18 W at 48 VDC
100 to 125 VDC: approx. 0.5 W at 125 VDC
Contact output: 5 A at 250 VAC/30 VDC, resistive load (cos φ = 1)
2
three times each in six directions
2
three times each in six directions
− 10 ° C to 55 ° C (with no icing),
− 25 ° C to 65 ° C (with no icing)
35% to 85%
100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h) (See note)
EN61812-1
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
IEC61000-4-2:
IEC61000-4-4:
IEC61000-4-5:
Solid-state Power OFF-delay Timer
Solid-state Power OFF-delay Timer
6 kV contact discharge (level 3)
8 kV air discharge (level 3)
IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
1 kV line to line (level 3)
2 kV line to ground (level 3)