Firefox GFG Series Installation & Operating Instructions Manual

Gas firegrates - log/coal effect

Advertisement

CONTROL
COVER PANEL
DECORATIVE FRONT IRON
This appliance must be installed by authorized personnel in accordance with
manufacturers instructions, gas fitting regulations, AGA 601 code for installation of
gas burning appliances, electrical wiring regulations and any other statutory
requirement. The guidelines here-in have been tested and approved to AS 4558/AG
INSTALLATION & OPERATING INSTRUCTIONS
'GFG' SERIES (GAS FIREGRATES - LOG/COAL EFFECT)
DIMENSION (mm)
MODEL
A
B
GFG 2.7
550
270
GFG 3.0
610
270
GFG 3.5
730
270
GFG 4.0
850
270
GAS - INPUT (Mj)
C
N. Gas
LP. Gas
200
36
200
41
200
52
200
52
108. AGA Approval No. 6386.
35
40
50
50
C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GFG Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Firefox GFG Series

  • Page 1 INSTALLATION & OPERATING INSTRUCTIONS ‘GFG’ SERIES (GAS FIREGRATES - LOG/COAL EFFECT) DIMENSION (mm) GAS - INPUT (Mj) MODEL N. Gas LP. Gas GFG 2.7 GFG 3.0 GFG 3.5 GFG 4.0 CONTROL COVER PANEL DECORATIVE FRONT IRON This appliance must be installed by authorized personnel in accordance with manufacturers instructions, gas fitting regulations, AGA 601 code for installation of gas burning appliances, electrical wiring regulations and any other statutory requirement.
  • Page 2 (See Example A detail). EXAMPLE B. Installation of the gas firegrate in conjunction with a Firefox OGF Series firebox which has been installed in accordance with Firefox instructions for open GAS Firebox (See Example B detail)
  • Page 3 INSTALLATION EXAMPLE A. DEFINITION The fireplace chamber must be wide Installation of a Firefox gas firegrate and deep enough to fully accommodate the gas (GFG) into an existing fireplace chamber and firegrate. It is preferable that the gas firegrate chimney which is completely constructed of...
  • Page 4 INSTALLATION EXAMPLE DETAIL A. GAS COWL ENSURE THAT CHIMNEY IS SMOKE MATCH UN-OBSTRUCTED TEST FOR & IN SOUND SPILLAGE WORKING ORDER GAS FIREGRATE GAS ENTRY CHAMBER WIDTH...
  • Page 5 DEFINITION Installation of the gas regrate/burner Permanent ventilation equal to the (GFG) in conjunction with a Firefox open fronted cross sectional area of the speci ed rebox ue pre-fabricated steel rebox (OGF) along with the must be provided into the room/area the gas re speci ed steel ue exhaust system.
  • Page 6 FIREFOX ‘OGF’ GAS FIREBOX SYSTEM WHICH MUST BE INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS F.L. FIREFOX ‘GFG’ GAS FIREGRATE * IMPORTANT GAS ENTRY USE ONLY THE APROPRIATE (GFG) IN CONJUCTION WITH THE APROPRIATE FIREFOX OPEN GAS FIREBOX (GFG) ELEC. SUPPLY...
  • Page 7: Burner Connection

    BURNER CONNECTION & ASSEMBLY LOG/COAL FRAME BURNER CONNECTION Select the appropriate Firefox gas firegrate/burner for the application. Run appropriate gas supply line in from right hand side with a tail of approx. ¾ way along the width of the fireplace.
  • Page 8 Logset Location (2.7 Model) BURNER CONNECTION & ASSEMBLY LOG/COAL ASSEMBLY Remove log frame from the burner tray by pulling upwards. Fill the burner tray with the ‘Cinder Effect Granules’ provided until the tray and burner tube is completely covered over with an approx. LOCATION LOCATION LOCATION...
  • Page 9 GFG 2.7 LOG SET ARRANGEMENT...
  • Page 10 Logset Location (3.0 Model) BURNER CONNECTION & ASSEMBLY LOG/COAL ASSEMBLY Remove log frame from the burner tray by pulling upwards. Fill the burner tray with the ‘Cinder Effect Granules’ provided until the tray and burner tube is completely covered over with an approx. 18-20mm thick layer of the ‘Cinder Effect Granules’.
  • Page 11 GFG 3.0 LOG SET ARRANGEMENT...
  • Page 12 Logset Location (3.5 Model) BURNER CONNECTION & ASSEMBLY LOG/COAL ASSEMBLY Remove log frame from the burner tray by pulling upwards. Fill the burner tray with the ‘Cinder Effect Granules’ provided until the tray and burner tube is completely covered over with an approx. 18-20mm thick layer of the ‘Cinder Effect Granules’.
  • Page 13 GFG 3.5 LOG SET ARRANGEMENT...
  • Page 14: Commissioning Procedure

    LIGHTING BURNER & COMMISSIONING LIGHTING AND SHUT DOWN PROCEDURE COMMISSIONING PROCEDURE Upon completion of the installation, To light the pilot from OFF position the installer must check for spillage. (See Fig 1) press the control knob in and turn anti-clockwise to PILOT (See Fig 2). Light the fire burner and allow to warm up for approx.
  • Page 15: Safety Precautions

    2. Check for spark at electrode. If none, check lead connection. If not solved replace Firefox Decorative Gas Firegrates burn with a live electrode. naked flame. It is important therefore in order to protect against personal injury or property damage 1.