Overview

The JY-6312 is an advanced channel-to-channel isolated thermocouple input module that offers
exceptional performance and versatility for a wide range of applications. With its 16 channels of
measurements, it allows simultaneous measurement of multiple thermocouples, making it ideal
for various industrial and testing environments. The module boasts high accuracy of up to 0.05%
full-scale, ensuring precise and reliable temperature measurements. Its 24-bit resolution captures
even the slightest temperature variations with great detail. Additionally, the JY-6312 incorporates
50 Hz/60 Hz noise rejection capabilities, minimizing interference from power line frequencies
commonly found in industrial settings. It also includes open thermocouple detection, alerting users
to any broken or disconnected thermocouple circuits. The module supports a wide range of voltage
inputs, making it compatible with various thermocouple types. With its 60 Vrms channel-to-
channel isolation, the JY-6312 provides reliable measurements even in noisy and demanding
environments. Whether for white goods testing, in-vehicle data logging, battery stack testing, or
other industrial applications, the JY-6312 offers the accuracy, reliability, and flexibility required for
precise thermocouple measurements.
JY-6312 V1.0.3 |
jytek.com
| 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JY-6312 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for JYTEK JY-6312 Series

  • Page 1: Jy-6312 Series Specifications

    1. JY-6312 Series Specifications High Accuracy 24-bit ch-to-ch isolated thermocouple input module  Please download <JYPEDIA>, you can quickly check the product price and main features. Overview The JY-6312 is an advanced channel-to-channel isolated thermocouple input module that offers exceptional performance and versatility for a wide range of applications. With its 16 channels of measurements, it allows simultaneous measurement of multiple thermocouples, making it ideal for various industrial and testing environments.
  • Page 2: Main Features

    Full J, K, T, E, N, B, R, S thermocouple range Overvoltage protection ±30 V ESD protecting 4 kV Synchronous acquisition Storage depth 64M Samples Differential input impedance 15 MΩ Typical DC linearity ±2 ppm Maximun DC linearity ±15 ppm Table 1 Input Characteristic JY-6312 V1.0.3 | jytek.com...
  • Page 3: Basic Voltage Accuracy

    35 uV 0.1562 0.025 + 0.011 54 uV 0.3125 0.030 + 0.008 120 uV 0.625 0.031 + 0.005 220 uV 1.25 0.031 + 0.007 470 uV Table 4 Basic voltage accuracy (@ 160 Hz sample rate) JY-6312 V1.0.3 | jytek.com...
  • Page 4: Temperature Measurement Accuracy

    Reference (Cold Junction Temperature): same as Operating Temperature The measurement errors do not include the errors from the thermocouple Terminal Block: TB-68CJ; Cable: ACL-2026868-01 Table 5 Temperature measurement accuracy Channel isolation JY-6312 has new designs including 60 Vrms channel-to-channel isolation and noise reduction. JY-6312 V1.0.3 | jytek.com...
  • Page 5: Simultaneous Measurement Of Thermocouples And Voltages

    Simultaneous measurement of thermocouples and voltages. JY-6312 not only measures thermocouples but also has the capability to measure ± 1.25V voltage (with a total of 6 voltage ranges), allowing simultaneous measurement of thermocouples and voltages. JY-6312 V1.0.3 | jytek.com...
  • Page 6: Open Thermocouple Detection (Otd)

    Open Thermocouple Detection (OTD) Table 6 Open Thermocouple Detection (OTD) Common Mode Voltage Range Channel-COM 0-3 V Channel-Channel 0-3 V COM-Earth ground ±300 V Table 7 Common Mode Voltage Range Table 8 PFI Specification JY-6312 V1.0.3 | jytek.com...
  • Page 7: Power Line Noise Rejection

    Table 10 Digital Trigger PXle-6312 PCle-6312 x4 PXI Expressperipheral Bus Type x4 PCI Express 2.0 module Specification V1.0 compliant x1 and x4 PXI Express Slot supported PXI Express hybrid x4/x8/x16 PCle slot slots Table 11 Bus JY-6312 V1.0.3 | jytek.com...
  • Page 8: Size

    Size Product Model Size(mm) Weight(g) PXle-6312 160 x 100 PCle-6312 167.7 x 111.2 *Length including connectors Table 12 Size Power Table 13 Power Specification Operating Environment Table 14 Operating Environment Storage Environment Table 15 Storage Environment JY-6312 V1.0.3 | jytek.com...
  • Page 9: Pin Connectors

    P61 TC+, Voltage measurement high side Reseved, Do not connect Ch15 P27 TC-, Voltage measurement low side Reseved, Do not connect Reseved, Do not connect Reseved, Do not connect Reseved, Do not connect + 5V Table 16 Pin Connectors JY-6312 V1.0.3 | jytek.com...
  • Page 10: Table Of Contents

    2. Table of Contents Specs and Manual Version: V1.0.3 Revision Date: May 17, 2024 Table of Contents JY-6312 Series Specifications ................... 1 Overview ........................... 1 Main Features ........................2 Input Characteristic ......................2 Basic Voltage Accuracy ......................3 Temperature Measurement Accuracy ................. 4 Channel isolation .........................
  • Page 11 System Software ....................... 22 C# Programming Language ....................22 C ++ Programming Language .................... 23 JY-6312 Hardware Driver ....................23 Install the SeeSharpTools from JYTEK ................23 Running C# Programs in Linux ..................23 JYPEDIA ........................24 Additional Software Information ................... 24 Python ..........................
  • Page 12 Figure 4 Ground loops generate common mode noise ............26 Figure 5 Magnetic field produces normal mode noise ............27 Figure 6 Electrostatic Noise Coupling into Thermocouples ............. 28 Figure 7 Three Thermocouple Types ..................29 JY-6312 V1.0.3 | jytek.com | 12...
  • Page 13: Temperature Measurement Specifications

    Table 17 shows the accuracies of common thermocouple types by two commonly used standards. Using the K-type as an example. Each K-type thermocouple falls into one of the three classes. The maximum accuracy of class 1 of the K-type thermocouple is ±1.5°C or ±(0.004*|T|), JY-6312 V1.0.3 | jytek.com | 13...
  • Page 14 T is the measured temperature value in °C. If the measured temperature is -30°C, 0.004*|-30| = 0.12°C, so the accuracy is ± 1.5°C. If T=1000°C, 1000*0.004=4°C, so the accuracy is ±4°C. JY-6312 V1.0.3 | jytek.com | 14...
  • Page 15 – ±(0.01 · |T|) 60584-1 Class 3 – – – Special – – – ASTM E230 ANSI MC96.1 Standard 0 < T < 2315 ±(0.01 · |T|) :Thermocouple Tolerance Class Information Table 17 Err JY-6312 V1.0.3 | jytek.com | 15...
  • Page 16: Temperature Measurement Accuracy By Jy-6312

    Test at 78.125 mV range Reference (Cold Junction Temperature): same as Operating Temperature The measurement errors do not include the errors from the thermocouple Terminal Block: TB-68CJ; Cable: ACL-2026868-01 :Temperature Measurement Accuracy Table 18 Err JY-6312 V1.0.3 | jytek.com | 16...
  • Page 17: Total Temperature Measurement Accuracy

    Table 18. It is not possible to list all these accuracies. JYTEK provides a utility in JY-6312 C# example to calculate the accuracy for those conditions. Users can enter required operating parameters to obtain accuracy not listed in Table 18.
  • Page 18: Additional Specifications

    OTD disabled input current: 200 pA(DS) Input bandwidth(-3 dB) Sampling Rate(Sample/s) 50Hz Rejection Mode 60Hz Rejection Mode 2 Hz 2 Hz 19 Hz 11 Hz 19 Hz 22 Hz 222 Hz 222 Hz 445 Hz 445 Hz JY-6312 V1.0.3 | jytek.com | 18...
  • Page 19: Timing And Trigger

    ReTrigger Software Software Software Software Polarity selectable selectable selectable selectable *SSI<0..7> definition please refer to section 6.7 Table 21 Timing and Trigger Specification Front Panel conections and Pinout Definition Figure 2 JY-6302 Front Panel JY-6312 V1.0.3 | jytek.com | 19...
  • Page 20 P61 TC+, Voltage measurement high side Reseved, Do not connect Ch15 P27 TC-, Voltage measurement low side Reseved, Do not connect Reseved, Do not connect Reseved, Do not connect Reseved, Do not connect + 5V Table 22 Pinout defination JY-6312 V1.0.3 | jytek.com | 20...
  • Page 21: Order Information

    TB-68CJ (PN: JY2010068-01) 68-Pin SCSI Shielded I/O Connector Block with cold junction sensor ACL-2026868-1 (PN: JY2026868-01) 1 M 68pin VHDCI68M-SCSI68M 100 ohm all shielded cable ACL-2026868-2 (PN: JY2026868-02) 2 M 68pin VHDCI68M-SCSI68M 100 ohm all shielded cable JY-6312 V1.0.3 | jytek.com | 21...
  • Page 22: Software

    Microsoft Windows: Windows 7 32/64 bit, Windows 10 32/64 bit. We highly recommend the user to use Windows 10 whenever possible. Linux Kernel Versions: There are many Linux versions. It is not possible JYTEK can support and test our devices under all different Linux versions. JYTEK will at the best support the following Linux versions.
  • Page 23: C ++ Programming Language

    Most C# written programs in Windows can be run by Microsoft Mono development system in a Linux enviornment. You would develop your C# applications in Windows using Visual Stuido. Once it is done, run this application in the Mono environment. This is JYTEK recommended way to run your C# programs in a Linux environment.
  • Page 24: Jypedia

    JYTEK provides and supports a native python driver for JY-6312 cards. There are many different versions of Python. JYTEK has only tested in Python version 3.5. There is no guarantee that JYTEK python drivers will work correctly with other versions of Python.
  • Page 25: Appendix

    In these configurations, the voltage bias is greater than 0V of the reference level. Therefore, the voltage bias of JY-6312 series input modules is not connected to the internal reference "ground" under any circumstances.
  • Page 26: Thermocouple Measurement Noise

    10.2.2 Normal Mode Noise Normal mode noise is typically generated by large AC power supplies that create magnetic fields that induce currents in the measurement loop. This noise generates current in the same direction JY-6312 V1.0.3 | jytek.com | 26...
  • Page 27 Let the measurement line intersect the high current line perpendicularly, thereby changing the direction of the magnetic field. Do not run thermocouples in parallel with power lines or other noisy signal lines. ◼ The normal mode current is reduced by filtering. JY-6312 V1.0.3 | jytek.com | 27...
  • Page 28: Electrostatic Noise

    JY-6312 V1.0.3 | jytek.com | 28...
  • Page 29: Influence Of Thermocouple Type On Measurements

    As shown in Figure Figure 7 Three Thermocouple Types Table 24 shows the definitions, advantages and disadvantages of different types of thermocouples, and their corresponding application areas. Table 24 Comparison of different thermocouple types JY-6312 V1.0.3 | jytek.com | 29...
  • Page 30: Thermocouple Installation Method

    Installation angle, the thermocouple installation should be kept as vertical as possible, if there is a flow velocity, the thermocouple installation should be inclined 45°; For the installation location, try to choose a location away from heat sources, electric fields and strong magnetic fields. JY-6312 V1.0.3 | jytek.com | 30...
  • Page 31: About Jytek

    About JYTEK JYTEK China Founded in June 2016, JYTEK China is a leading Chinese test & measurement company, providing complete software and hardware products for the test and measurement industry. The company is a joint venture between Adlink Technologies and a group of experienced professionals form the industry.
  • Page 32: Jytek Warranty And Support Services

    JYTEK Warranty and Support Services With our complete software and hardware products, JYTEK is able to provide technical and sales services to wide range of applications and customers. In most cases, our products are backed by a 1-year warranty. For technical consultation, pre-sale and after-sales support, please contact JYTEK of your country.
  • Page 33: Statement

    Statement The hardware and software products described in this manual are provided by JYTEK China, or JYTEK in short. This manual provides the product review, quick start, some driver interface explanation for JYTEK JY9516 Series of dynamic signal analyzer modules. The manual is copyrighted by JYTEK.

Table of Contents