adstec MED9000 Series Instruction Manual

adstec MED9000 Series Instruction Manual

Industrial monitors

Advertisement

Quick Links

Translation of the original instruction manual
Version 1.0
Last changed: 2024-05-21
Instruction manual
Industrial monitors
MED9000 series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MED9000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for adstec MED9000 Series

  • Page 1 Translation of the original instruction manual Version 1.0 Instruction manual Industrial monitors MED9000 series Last changed: 2024-05-21...
  • Page 2 MED9000 series − Instruction manual v1.0 Read these instructions carefully before using and store for future reference. These instructions contain important information about the product, in particular about its intended use, safety, installation, utilisation, maintenance and disposal. Hand over the instructions to the user following installation of the product, and pass the manual on to the new user if the product is resold.
  • Page 3: Table Of Contents

    MED9000 series − Instruction manual v1.0 Contents General information about documentation ................5 General information Explanation of safety instructions 1.2.1 Structure of safety instructions 1.2.2 Explanation of signal words Relevant device documentation Symbols Data, figures and modifications Trademarks Copyright General device information ...................... 9...
  • Page 4 MED9000 series − Instruction manual v1.0 Commissioning ........................33 Requirements Switching the device on Features ..........................34 DisplayPort™ HDBaseT™ Cleaning ..........................34 Dimensional drawings ......................35 MED9016 MED9019 MED9024 Tragarm Tastaturhalter Fehler! Textmarke nicht definiert. 10 Technical data ........................40 11 Service &...
  • Page 5: General Information About Documentation

    MED9000 series − Instruction manual v1.0 1 General information about documentation 1.1 General information The purpose of this instruction manual is to ensure the safe and efficient use of type MED9000 − industrial monitors, hereinafter referred to as the "device".
  • Page 6: Explanation Of Signal Words

    MED9000 series − Instruction manual v1.0 1.2.2 Explanation of signal words DANGER Indicates an imminent danger. If not avoided, death or severe injury will result. WARNING Indicates a possible danger. If not avoided, death or severe injury could result. CAUTION Indicates a possible danger.
  • Page 7: Relevant Device Documentation

    MED9000 series − Instruction manual v1.0 1.3 Relevant device documentation The following documents are decisive to device setup and operation: • This instruction manual: contains information for installation, commissioning and operation of the device along with technical data. • Website:...
  • Page 8: Trademarks

    MED9000 series − Instruction manual v1.0 1.6 Trademarks It is noted that any software and/or hardware trademarks and any company brand names mentioned in this documentation are all subject to the general trademark protection rights. Big-LinX and X-Remote are registered trademarks of ADS-TEC.
  • Page 9: General Device Information

    MED9000 series − Instruction manual v1.0 2 General device information 2.1 Manufacturer and contact details The manufacturer of the device is ads-tec Industrial IT GmbH. The company is referred to in the following as ADS-TEC. ads-tec Industrial IT GmbH Heinrich-Hertz-Str.1 72622 Nürtingen...
  • Page 10: Improper Use

    MED9000 series − Instruction manual v1.0 2.3 Improper use Operation other than or beyond that described for the device shall be deemed improper use. The device is not allowed to be used to control vehicles or for applications for which further approvals beyond the manufacturer's declaration are necessary, e.g.
  • Page 11: Environmental Conditions

    MED9000 series − Instruction manual v1.0 2.4 Environmental conditions ATTENTION Damage caused by heat If the device is exposed to sunlight or any other light or heat source, it can overheat and suffer damage.  Do not expose the device to direct radiation by sunlight or any other light or heat source.
  • Page 12: Vibration/Shock Resistance

    MED9000 series − Instruction manual v1.0 2.4.1 Vibration/shock resistance The vibration/shock resistance tests were performed as follows: Vibration near machines or conveyor belts − DUT: functional device Test standard: EN 60068-2-6 − − Deflection shape: sinusoidal Test axes: X / Y / Z −...
  • Page 13: Conformity

    MED9000 series − Instruction manual v1.0 2.5 Conformity The manufacturer hereby declares that the product described in this instruction manual complies with all relevant stipulations of the following European directives: • 2011/65/EU, RoHS Directive • 2014/30/EU, EMC Directive • 2014/35/EU, Low Voltage Directive •...
  • Page 14: Warranty / Repairs

    MED9000 series − Instruction manual v1.0 2.6 Warranty / repairs During the device warranty period, any repairs must only be performed by the manufacturer or by service personnel that has been authorised by the manufacturer. 2.7 Limitation of liability ADS-TEC shall not be liable for personal injury, property damage or damage caused to the device as...
  • Page 15: Scope Of Delivery

    MED9000 series − Instruction manual v1.0 3 Scope of delivery Check that the contents of the package are intact: If there are signs of damage, please contact the manufacturer immediately. The device must not be put into operation. Check that the contents of the package are complete and match your order: 1 x device −...
  • Page 16: Mechanical Installation

    MED9000 series − Instruction manual v1.0 4 Mechanical installation 4.1 Requirements The external device dimensions are given in chapter 9 Dimensional drawings. 4.2 Attaching to a VESA 100 interface The device can be attached to the VESA 100 interface on the rear side.
  • Page 17: Attaching Using A Tube Adapter

    MED9000 series − Instruction manual v1.0 4.3 Attaching using a tube adapter 1. Deburr the end of your support tube (diameter 48.3 mm). 2. Stick the drilling template around the end of the support tube so that the holes to be drilled are located on the rear side of the tube.
  • Page 18 MED9000 series − Instruction manual v1.0 5. Apply a suitable lubricant to the seal and the tube end to make it easier to slide on the sealing sleeve (e.g. penetrating oil, soap or fitting grease, depending on the application type).
  • Page 19 MED9000 series − Instruction manual v1.0 9. Route all of the required cable lines through the tube adapter and the tube. 35.5 mm ≤ 16.2 mm ≤ 35.1 mm 10. Attach the tube adapter to the tube: © ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 20 MED9000 series − Instruction manual v1.0 11. Align all of the parts so that the holes in the tube and in the tube adapter are positioned on top of one another and the threaded pins can be screwed in again.
  • Page 21 MED9000 series − Instruction manual v1.0 … and turn it until it is sufficiently tight: Recommendation: In the first step, the nut is used to eliminate any remaining play (looseness). It is turned until the tube adapter sits on the device without any play.
  • Page 22: Swivel Angle Limitation

    MED9000 series − Instruction manual v1.0 4.3.1 Swivel angle limitation Without pins, the screen can be swivelled by 270°. With the cylindrical pins (2.5 x 10 mm) from the scope of delivery, this angle can be limited. The following graphic shows the positions of the cylindrical pins and the internally specified angles:...
  • Page 23 MED9000 series − Instruction manual v1.0 This results in the following swivel angles for the monitor: © ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 24: Attaching The Ip65 Kit

    MED9000 series − Instruction manual v1.0 4.4 Attaching the IP65 kit 4.4.1 Dimensions of the grommets The IP65 kit includes two grommets through which cables can be routed. The grommets have different hole diameters and should be used as required.
  • Page 25: Dimensions Of The Retainer

    MED9000 series − Instruction manual v1.0 4.4.2 Dimensions of the retainer 4.4.3 Attaching the grommets 1.) Route all of the required cable lines through the opening in the device, the cable grommet and the retainer. 2.) When doing so, pay attention to - the different hole diameters in the supplied grommets as specified in section 4.4.1,...
  • Page 26: Opening And Closing The Service Slot

    MED9000 series − Instruction manual v1.0 3.) Insert the appropriate rubber plugs into any holes that are not required. 4.) Press the grommet into the opening in the device. 5.) Press the retainer against the grommet and tighten the two screws.
  • Page 27: Attaching The Scanner Holder

    MED9000 series − Instruction manual v1.0 4.6 Attaching the scanner holder 4.6.1 Pre-assembly Mounting on the right-hand side (seen from the front): Mounting on the left-hand side (seen from the front): © ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 28: Attaching To The Vesa Interface

    MED9000 series − Instruction manual v1.0 4.6.2 Attaching to the VESA interface The scanner holder is attached to the VESA 100 interface, cf. section 4.2. The screw length must be selected taking into account the material thickness of the brackets used and the screw-in depth in the threaded bushes on the back of the device.
  • Page 29: Attaching Other Accessories

    MED9000 series − Instruction manual v1.0 4.7 Attaching other accessories On the top and bottom of the device, there are threaded holes into which the optional screw-in sleeves can be screwed if required. Installing the screw-in sleeves: The sleeves must be screwed into the housing with a torque of M = 8.5 ± 0.5 Nm. The external thread has an encapsulated adhesive coating that ensures lasting hold.
  • Page 30: Electrical Connections

    MED9000 series − Instruction manual v1.0 5 Electrical connections 5.1 Requirements ATTENTION Damage due to electrostatic discharge Damage to the device can be caused by electrostatic discharge. Always adhere to the safety measures applicable when handling components at risk of being •...
  • Page 31: Interface Overview

    MED9000 series − Instruction manual v1.0 5.3 Interface overview Protective earth (PE) connection, see section 5.2 Power supply, see section 5.4 DisplayPort 1.2 HDMI 3 x USB 2.0 type A 1 x USB 2.0 type B Optional: HDBaseT extender (RJ45) 5.4 Power supply...
  • Page 32: Maximum Cable Lengths

    MED9000 series − Instruction manual v1.0 5.5 Maximum cable lengths Recommendation for use: Note the maximum cable lengths for the respective application type. The maximum length of cables which can be used to connect the monitor and computer is: HDMI up to max. 15 m −...
  • Page 33: Commissioning

    MED9000 series − Instruction manual v1.0 6 Commissioning 6.1 Requirements ATTENTION Hazard due to condensation Damage to electronic components caused by condensation resulting from temperature fluctuations. Switch on the device only after it has acclimated to the ambient temperature. •...
  • Page 34: Features

    MED9000 series − Instruction manual v1.0 7 Features 7.1 DisplayPort™ The devices have a receiver module that conforms to DisplayPort 1.2. 7.2 HDBaseT™ With HDBaseT™, the connection between the computer and monitor is established using a LAN cable with RJ45 plugs. The distances that can be bridged depend on the network infrastructure used: with a CAT6a patch cable without sockets etc.: maximum 70 m...
  • Page 35: Dimensional Drawings

    MED9000 series − Instruction manual v1.0 9 Dimensional drawings 9.1 MED9016 © ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 36: Med9019

    MED9000 series − Instruction manual v1.0 9.2 MED9019 © ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 37: Med9024

    MED9000 series − Instruction manual v1.0 9.3 MED9024 © ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 38: Tragarm

    MED9000 series − Instruction manual v1.0 9.4 Support arm © ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 39 MED9000 series − Instruction manual v1.0 9.5 Keyboard holder © ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 40: Technical Data

    MED9000 series − Instruction manual v1.0 10 Technical data MED9016 MED9019 MED9024 Display 15.6“ TFT Full HD 18.5“ TFT Full HD 23.8“ TFT Full HD Brightness 450 Nits (typ.) 500 Nits (typ.) 250 Nits (typ.) Contrast ratio 800:1 (typ.) 1000:1 (typ.) 1000:1 (typ.)
  • Page 41: Service & Support

    MED9000 series − Instruction manual v1.0 11 Service & support ADS-TEC and its partner companies offer you comprehensive maintenance and support services, ensuring quick and competent support should you have any questions or concerns with regard to ADS- TEC products and equipment.