Page 1
May 2014 Copyright 2009-2014 Huntron, Inc. All rights reserved. Huntron, Tracker and Huntron Access are registered trademarks of Huntron, Inc. All other names are trademarks or registered trademarks of their respective companies. This document may not be copied in whole or in part, or otherwise reproduced except as specifically permitted under U.S.
Page 2
Huntron software, shall not exceed the amount of the purchase price of the Huntron Scanner II Model 30S, regardless of the extent of any such damage, including any special, consequential, or incidental damages of any kind.
SECTION 1 INTRODUCTION & SPECIFICATIONS 1-1. INTRODUCTION The Huntron Scanner II, shown in Figure 1-1, has been designed as a compatible interface for the Huntron Tracker Model 30. Together, they create an effective test system for component troubleshooting. The Scanner II allows faster comparison testing of components and boards by the use of direct cabling and optional IC clip cables for in- circuit ICs (integrated circuits).
OPERATING INSTRUCTIONS 1-2. SPECIFICATIONS The specifications for the Scanner II are listed in Table 1-1. ELECTRICAL Interconnections: Channels Number ........2 Pins Test ..........64 per channel Common ........64 per channel Connectors SCSII-2 ........68 pins each channel Power Requirements 5Vdc 0.05A GENERAL Size ............
Pour votre sécurité toujours suivre les instructions à côté du symbole de l'unité et dans le manuel. The Huntron Scanner II Model 30S conforms to the following Standards: EN 55011 EN 61000-3-2:2000...
This section describes the basic operation of the Huntron Scanner II. Throughout the rest of this manual the Huntron Scanner II will be referred to simply as the Scanner II. Take time to read this section carefully so that you can take full advantage of all its capabilities.
Table 2-1. Figure 2-1. External Features Item Item Description Input DB15 Connector Connection to the Huntron Tracker Model 30 or Previous Scanner II in the chain. Output DB15 Connects to the next Scanner II in the chain. Connector Channel Switch Sets Channel 2 to Tracker Channel A or B.
3. Note the Channel 2 switch setting on the back of the Scanner II. It will be set to “A” or “B”. 4. Start Huntron Workstation and select Tools/Maintenance/Tracker Model 30 Diagnostics from the menu. 5. In the Tracker Model 30 Diagnostics set the “Channels” setting to 1 if the Scanner II Channel 2 switch is set to “A”.
2. Connect the loose ends of the breakout cable to connector or test pins on the UUT. 3. Connect the Common test lead from the Tracker Model 30 a common point (i.e. ground) on the UUT. You can also set common pins using the Huntron Workstation software.
Page 11
OPERATING INSTRUCTIONS devices. Using the normal procedure above you can see a fault on one bus line, but you do not know which IC is causing it since they are all in parallel. In this case try using one of the “non-bussed”...
2-2. Figure 2-2 Four bottom left connector pins breakout Huntron can supply a 68 pin breakout cable that can be used for functions such as connecting to a custom interface or a quad IC clip. IMPORTANT NOTE: The individual pins on the breakout cable are labeled for counting on the Scanner front panel as a DIP package.
Page 13
The orders relate to the “Package” type selected for component in Huntron Workstation. The package types available for use with the Scanner II are shown in figure 2-3. The Channel 2 switch setting refers to the switch on the Scanner II back panel that allows configure Channel 2 as either “A”...
Page 14
The Scanner Adapter mounts to the front panel of the Scanner II using screws included with the Adapter. These screws replace the flathead screws used to mount the Scanner front faceplate. Figure 2-5 Scanner Adapter accessory and the Scanner II 2-12 Huntron Scanner II...
Page 15
OPERATING INSTRUCTIONS The Scanner Adapter scan pin order also varies based on Package type. Figure 2-5 shows how each Scanner II packages counts through the Adapter connectors. Figure 2-6 Scanner Adapter pin breakout based on Package type Operation Manual 2-13...
Should the Scanner II case require cleaning, wipe the instrument with a cloth that is lightly dampened with water or mild detergent solution. 2-8. STORAGE INSTRUCTIONS For optimum protection, store unit indoors in a dry place. 2-14 Huntron Scanner II...