Advertisement

Quick Links

              
 
Atom User's Manual
                       
The Atom Environmental Sensor monitors Temperature, Humidity (%), Pressure 
(mbar) and Irradiance (W/m²) and can also detect movement and door closures.  
The Atom sensor can be paired to an iOS device or paired to a PMI Tensor or Seeker 
Data is viewed on the PQ Canvass website using standard web browsers.
 
 
 
  
Power Monitors, Inc.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
recorder.   
 
A PQ Canvass login is required. 
 
1
 
  
                                  

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Atom and is the answer not in the manual?

Questions and answers

Summary of Contents for PMI Atom

  • Page 1                  Atom User’s Manual                           Power Monitors, Inc.                                                                     The Atom Environmental Sensor monitors Temperature, Humidity (%), Pressure  (mbar) and Irradiance (W/m²) and can also detect movement and door closures.   The Atom sensor can be paired to an iOS device or paired to a PMI Tensor or Seeker  recorder.      Data is viewed on the PQ Canvass website using standard web browsers. A PQ Canvass login is required.            ...
  • Page 2: Table Of Contents

    Contents  Introduction Getting Started with the Atom About the Atom Connecting the Atom to PQ Canvass Remove Associated Device Connecting the Atom to the PMI Atom App Devices Screen Setting Alerts Alert Thresholds Alert Notifications Atom LED Codes Technical Specifications Additional Information Technical Support Appendix 1: Warranty Clause Equipment Return Appendix 2: Regulatory Information FCC Warning                           ©2024 Power Monitors, Inc. All Rights Reserved   In no event shall the copyright owner or contributors be liable for any direct, indirect, incidental,  special, exemplary, or consequential damages (including but not limited to, procurement of  substitute goods or services).  In no event shall the copyright owner or contributors be liable for  any business interruption or loss of use, data, or profits however caused.  In no event shall the  copyright owner or contributors be liable for any business interruption or loss of use, data, or  profits on any theory of liability, whether in contract, strict liability, or tort (including negligence  or otherwise) arising in anyway out of the use of this software, even if advised of the possibility of  such damage.  Contents are subject to change without notice.  Screenshots used for illustrative  purposes are the property of Power Monitors, Inc.   Help us improve our manual.  Your comments and suggestions are important to us.    Please contact us at the email powerquality@powermonitors.com      ...
  • Page 3: Introduction

                            1/11/2024  Introduction   Power Monitors Incorporated (PMI) was founded to provide state-of-the-art, easy-to-use, and  affordable electronic test equipment to the power industry. PMI products have been developed by  working directly with electric utilities to determine their specific needs. The Atom has also been  developed by following these same principles.      If you have any questions about its operation, ideas for new features, or ideas for additional  products please contact PMI. We want you to be happy with this product and would appreciate any  input that could help us develop products to meet your future needs.       Getting Started with the Atom   The  Atom, at time of purchase, will be added to your PQ Canvass account.     Your Atom can be associated to a PMI recorder. The data is sent through the recorder to the PMI PQ  Canvass cloud for viewing using a web browser, or you can connect the Atom to an iOS device using  the Atom application (app) and view live data as well as upload data to the PQ Canvass cloud.    You will need to be an administrative user in PQ Canvass to manage the Atom.  If you do not have administrative access, call the PMI Tech Support team at (800)296-4120.    Note: The Atom can only be associated with a single recorder, but a recorder can have multiple  Atoms associated to it.     ...
  • Page 4: About The Atom

    About the Atom        ...
  • Page 5: Connecting The Atom To Pq Canvass

    Connecting the Atom to PQ Canvass     Note: See the PQ Canvass User Guide for more information on viewing data  Log into your PQ Canvass account  https://pqcanvass.powermonitors.com Select the Device icon at the bottom of the page  .  Verify your cellular or Wi-Fi Tensor or  cellular Seeker is online in PQ Canvass. Also verify your Atom is listed.    All recorders and Atoms will be listed on the PQ Canvass Devices page  . Unassociated Atoms  are listed separately. Paired Atoms are listed under the associated recorder.                                                            Place the Atom close to the Tensor or Seeker recorder that it will be paired to:     Press the Activation button and hold the button for 8 -12 seconds to ‘wake up’ the Atom. You will  see the Atom’s LED flash white 3 times. Press and release the Activation button 5 times. You will  see 2 white flashes and then the LED will blink blue indicating it is searching for a Bluetooth®  connection. This action is normally performed once when first receiving the Atom. The Bluetooth®  will periodically turn on to sync to the paired device. Pressing the Activation button once will force  the Bluetooth® on.  To add an Atom to a Tensor or a Seeker, in PQ Canvass, click on the Seeker or Tensor you want to  pair the Atom to.    Select the Actions icon   Then select the Atom Discovery icon      ...
  • Page 6 The serial number of the Atoms available to pair are listed     Find the correct Atom and select ‘Pair’  Note: The Seeker or Tensor must be online to associate with an Atom    The associated recorder will be listed     Select the X in the upper right corner to close    Once paired, the Atom is nested directly below the parent Seeker or Tensor Select the arrow to expand   ...
  • Page 7 Select the Atom to see the ‘Quick Access View’ page                          To view data, select the Overview button.  See the PQ Canvass User Manual for complete description of the listed icons                    ...
  • Page 8     The Graphs button on the ‘Quick Access View’ page, displays additional graph options                    Use the Reports button on the ‘Quick Access View’ page to view and save Interval reports                  ...
  • Page 9     Use the Alert Thresholds button on the ‘Quick Access View’ page to view or change alert settings.    Alerts are sent to the user’s email, see setting Alerts later in this manual.   Reed Switch and Accelerometer configurations are set here with additional settings on the Quick  Access View Settings page (see below).                                                ...
  • Page 10   The Info button on the ‘Quick Access View’ page displays the Atom’s information                                          ...
  • Page 11     The Settings button on the ‘Quick Access View’ page can be used to view or edit select settings.  The accelerometer setting determines how the Magnetic Reed switch responds to the Alert  settings. If using this setting also set the Alert Thresholds                     ...
  • Page 12: Remove Associated Device

    Remove Associated Device     To remove the Atom from the associated Seeker or Tensor, click the -    shown on the right  of the Atom and press OK to remove. The Atom can now be associated to another recorder or  paired to an iOS device such as an iPhone or iPad.      You can also disassociate an Atom by selecting the Actions button on the Tensor or Seeker Quick  Access View page, then select the Associated Devices button and select the X listed to the right of  the Atom      Select the blue diskette icon   to confirm removal           ...
  • Page 13: Connecting The Atom To The Pmi Atom App

    Connecting the Atom to the PMI Atom App     The PMI Atom app is used to access Atom data using an iOS Apple product such as the iPad or  iPhone  Verify you have Bluetooth® enabled on your Apple product.     The PMI Atom app can be downloaded from the Apple store.    Use your PMI PQ Canvass account login to enter the Atom app.  Select the icon for the Atom App         Sign in using your PQ Canvass login               ...
  • Page 14         Once logged in, you can select items from the bottom of the page.     Note: If you have multiple PQ Canvass accounts, a screen will show which will allow you to choose  a specific account.    The account detail page contains some settings and access to the User Guide. Selecting PQ Canvass  will open a browser with the PQ Canvass website.   Location brings up a map with the Devices location if set ( the default location is longitude 0 ,  latitude 0)        Account Details – expanded ...
  • Page 15: Devices Screen

        Devices Screen When the Atom App connects to the Atom, the serial number and RSSI (signal strength) will be  displayed  Specific filters can be selected.    Click on the serial number listed                           ...
  • Page 16       Note: If the Atom has not connected recently, push the Activation button on the Atom one time to  ‘wake up’ the Bluetooth® connection. Once the Bluetooth® connection is established the Fetching  Data Screen will show for a few seconds.    Note: An Atom that is not connected will list only the General Info tab and the Thresholds tab.              ...
  • Page 17 Selecting  the Start Scanning button, will retrieve data from the Atom and send it to PQ Canvass (If  the iOS device is not connected to the Internet, the data is placed under the ‘Saved Data’ tab on  the iOS device to manually send later).    Open the link to PQ Canvass to view the data      Select Sensor Readings tab to view the latest data.                        ...
  • Page 18 General Information tab can be used to associate the Atom to a PMI recorder and disassociate the  Atom from the PMI recorder and change the location of the Atom on the PQ Canvass map.      Thresholds tab Settings are similar for Pressure, Humidity, Temperature (shown) and Irradiance.         ...
  • Page 19 Alerts Tab  Displays Atom status based on the Threshold settings              ...
  • Page 20: Setting Alerts

    Setting Alerts   There are two areas that are used to configure alerts; one is the Threshold settings in PQ Canvass  or in the iOS Atom app, the other are the Notification settings in PQ Canvass.    Alerts are sent to the PQ Canvass users’ email, or to a PQ Canvass account created with an SMS  address. Check with your cellular provider (ex: <10-digit-number>@txt.att.net, <10-digit- number>@sprintpaging.com, <10-digit-number>@myvzw.com).    Alerts sent to an email address include the graph of the alert, but PMI Tech Support can set this to  Text Only if needed.    Alert Thresholds Select Alert Thresholds from the Quick access View page in PQ Canvass                                            ...
  • Page 21 Then select the specific settings you want to monitor. You can select just one of the settings, or the  full range of the settings. The Reed Switch and Accelerometer will generate Event notices which do  not contain graphs.  Select  ‘Set Thresholds’ to save the settings.     The Hold-off Time can limit the number of alerts sent. An alert will not be sent until the event  reaches the specified number of minutes. No alert is sent if the alarm condition returns to normal  before the Hold-off value is reached.    Hysteresis is used as a pad value that defines a narrow band above and below each threshold. A  measurement must exceed the programmed threshold plus (or minus) the hysteresis value for that  measurement to be used for alert triggering.                  ...
  • Page 22: Alert Notifications

      In the iOS Atom app, select Thresholds from the device screen and select one of the settings, or  the full range of the settings.      Alert Notifications To set the Notification, in PQ Canvass select the Tools icon   at the bottom of the screen. Then  select the Notification settings icon  . If you do not see the Notification icon, contact PMI Tech  Support to make you and administrative user.             ...
  • Page 23   Select the + to add a Notification List    A notification list can be one person getting alerts from one recorder or multiple users getting the  same alerts  from multiple recorders. Aggregate is the number of minutes to collect all the alerts  before the email is sent.  Holdoff is the number of minutes to wait before sending the alert email. Both are used to prevent  numerous emails over a short period of time. Both can be adjusted at a later date.   Select the Save icon  , or the discard icon    Now that a Notification list is create, set the Devices, Users, Alerts and Events.    Devices will show all the recorders for your account. Click the + to select one, multiple, or all  devices.    Users will show every user for your account. Click the + to select one, multiple, or all users.   ...
  • Page 24         Alerts will have many selections; many are not for the Atom sensor. Click the + to select one or  many alerts.  Select ‘Update’ to save settings.  Note: Your selections must match to the Thresholds set earlier.  Atom Alerts:     ...
  • Page 25 There are also Event selections that are not used for an Atom sensor. Select the events and then  the Update button to save. Events also need to match the Thresholds selections.   Irradiance Alert example:      Event orientation message example:     ...
  • Page 26     Temperature alert and graph example:     ...
  • Page 27: Atom Led Codes

    Atom LED Codes Green Blink - Unit is collecting data  Blue Blink - Bluetooth radio turned on, looking for a device to send data to.  Blue Blink (twice) – Tensor/Seeker connected to Atom. Data is being transferred.  Aqua - A Tensor/Seeker has connected recently (within 6 minutes) to the Atom but has not  connected since.              Data is waiting to be sent to the Seeker/Tensor  Yellow - Waiting for NTP server to be set (Occurs when the Atom is first turned on and has not yet                  connected to a Seeker, Tensor or the Atom app)    Technical Specifications   Temperature: -20C to 60C  Pressure: 500 - 1100 hPa  Humidity: 10-95% RH  Solar Flux: 100 - 100,000 lux  Acceleration drop and vibration detection  Magnetic Reed Switch: door closure detection  Environmental Rating: IP68  Communication: Wireless BLE 5.0 Radio  Sensor data read every minute  On-board Memory: 1 Year  Battery Life: 10 years  Weight: 2 ounces        ...
  • Page 28: Additional Information

    Additional Information Network Time Protocol (NTP) is synced with the Tensor or Seeker each time the Atom connects  The Atom’s battery is currently expected to last 5 to 10 years.  Irradiance is used instead of Solar Flux. Think sunshine instead of a light bulb.  The Atom can only connect to a single recorder, it must then be dissociated and associated to  another recorder if needed.   The Atom holds data for up to a year until it can connect to a device to send that data.   Refer to the PQ Canvass User manual for more information on using PQ Canvass      Technical Support Help is always available if one needs additional assistance.  The technical support team at PMI is  widely considered to be the best in the industry.  Use one of the following methods to obtain  technical support:  E-mail Support  Send e-mail to: techsupport@powermonitors.com Web Support  Submit a support request via the web at https://www.powermonitors.com/support Telephone Support Contact us 24 hours a day, 7 days a week for live tech support by calling: (540) 434- 4120   Faxes should be sent to: (540) 432-9430  Postal Mail Support All correspondence by post should be addressed to:   Power Monitors, Inc.  800 North Main Street  Mt. Crawford, VA 22841USA ...
  • Page 29: Appendix 1: Warranty Clause

    Appendix 1: Warranty Clause   Power Monitors Inc. (PMI) warrants each new product manufactured and sold to be free from  defects in material, workmanship, and construction, and that when used in accordance with this  manual will perform to applicable specifications for a period of one year after shipment.      If examination by PMI discloses that the product has been defective, then our obligation is limited  to repair or replacement, at our option, of the defective unit or its components.  PMI is not  responsible for products that have been subject to misuse, alteration, accident, or for repairs not  performed by PMI.      The foregoing warranty constitutes PMI’s sole liability and is in lieu of any other warranty of  merchantability or fitness.  PMI shall not be responsible for any incidental or consequential  damages arising from any breach of warranty.  Equipment Return If any PMI product requires repair or is defective, call PMI at (800) 296-4120 before shipping the unit  to PMI.  If the problem cannot be resolved over the phone, PMI will issue a return authorization  number.  For prompt service, all shipments to PMI must include:  1. The billing and shipping address for return of equipment  2. The name and telephone number of whom to contact for further information  3. A description of the problem or the work required  4. A list of the enclosed items and serial numbers  5. A return authorization number  6. If possible, a copy of the original invoice  Equipment returned to PMI must be shipped with freight charges prepaid.  After repair, PMI will  return equipment F.O.B. factory.  If equipment is repaired under warranty obligation, freight  charges (excluding airfreight or premium services) will be refunded or credited to the customer’s  account.    Return equipment to:  Power Monitors Inc.  800 North Main Street  Mount Crawford, VA 22841 USA  Attention: Repair Department ...
  • Page 30: Appendix 2: Regulatory Information

    Appendix 2: Regulatory Information U.S. FCC Part 15 and Industry Canada RSS 210 Statements    This device complies with part 15 of the FCC Rules. Operation is subject to the following two  conditions:   1. This device may not cause harmful interference and    2. This device must accept any interference received, including interference that may cause  undesired operation.      FCC Warning Changes or modifications to this product not expressly approved by Power Monitors, Inc. could  void the user’s authority to operate this equipment.           ...

Table of Contents