Cleaning, Care & Maintenance; Cleaning The Condenser; Troubleshooting - Koldbox KXR200 Instruction Manual

Abs storage refrigerator / freezer
Table of Contents

Advertisement

Press this key and the display will show the set temperature. Press the Key again to return to normal reading.
Set new temperature:
Press this Key and the display shows the set temperature.
Prss this key to increase the set temperature.
Pres this key to lower the set temperature.
Press this key to save the new settings. The display will flash with the new value and will then return to normal
reading.
Alarm codes:
PF1 Flashing in the display: indicates that the cabinet sensors is defective.
The cabinet will strive to keep the set temperature until it has been repaired.
PF1 Flashing in the display: indicates that the cabinet sensors is defective.
This does not influence the operation of the cabinet, but should be repaired as soon as possible.
Cleaning, Care & Maintenance
Switch off and disconnect from the power supply before cleaning.
Clean the interior of the appliance as often as possible.
Freezer models will need switching off to manually defrost when ice builds up to 5mm thick on the shelves.
Do not use abrasive cleaning agents / sanitizer sprays. These can leave harmful residues.
Clean the door seal with water only.
Always wipe dry after cleaning.
Do not allow water used in cleaning to run through the drain hole into the evaporation pan.
Take care when cleaning the rear of the appliance. Sharp edges can cut.
If the unit is to be switched off for prolonged periods, leave the door ajar to allow to dry out thoroughly.
An agent or qualified technician must carry out repairs if require.

Cleaning the Condenser

Periodically cleaning the condenser can extend the life of the appliance.
We recommend that your agent or qualified technician clean the condenser

Troubleshooting

If your appliance develops a fault, please check the following table before making a call to your retailer.
Fault
Probable Cause
The appliance is not
The unit is not switched on
working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
The appliance turns
Too much ice on the evaporator
on, but the
Condenser blocked with dust
temperature is too
Doors are not shut properly
high/low
Appliance is located near a heat source or air
flow to the condenser is being interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being stored in the
appliance
Appliance is overloaded
The appliance is
The appliance is not properly leveled
leaking water
The discharge outlet is blocked
Movement of water to the drain is obstructed Clean the floor of the appliance ( if applicable)
The water container is damaged
Action
Check the unit is plugged in correctly and switched on
Call your agent or qualified Technician
Replace the fuse
Check power supply
Call your agent or qualified Technician
Defrost the appliance
Call your agent or qualified Technician
Check doors are shut and seals are not damaged
Cabinet is not levelled correctly affecting door alignment
Move the refrigerator to a more suitable location
Increase ventilation or move appliance to a cooler
position
Remove any excessive hot foodstuffs or blockages to the
fan
Reduce the amount of food stored in the appliance
Adjust the screw feet to level the appliance (if appliance)
Clean the discharge outlet
Call your agent or qualified Technician

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KXR200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Kxf200

Table of Contents