Vega B62-30W Operating Instructions Manual

Overvoltage protection for profibus pa and foundation fieldbus circuits
Hide thumbs Also See for B62-30W:

Advertisement

Quick Links

Operating Instructions
Overvoltage protection
B62-30W
For Profibus PA and Foundation Fieldbus
circuits
Document ID: 40492

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B62-30W and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vega B62-30W

  • Page 1 Operating Instructions Overvoltage protection B62-30W For Profibus PA and Foundation Fieldbus circuits Document ID: 40492...
  • Page 2: Table Of Contents

    Approvals for Ex areas ....................16 Conformity ........................16 Environment management system ................. 16 Supplement ..........................17 Technical data ........................ 17 Dimensions B62-30W ....................18 Industrial property rights ....................20 Trademark ........................20 Editing status: 2024-04-22 B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 3: About This Document

    Symbols used Document ID This symbol on the front page of this instruction refers to the Docu- ment ID. By entering the Document ID on www.vega.com you will reach the document download. Information, note, tip: This symbol indicates helpful additional infor- mation and tips for successful work.
  • Page 4: For Your Safety

    During work on and with the device, the required personal protective equipment must always be worn. Appropriate use The B62-30W is an overvoltage arrester for supply and control cables for Profibus PA instruments. You can find detailed information about the area of application in chapter "Product description".
  • Page 5: Installation And Operation In The Usa And Canada

    Installations in the US shall comply with the relevant requirements of the National Electrical Code (NEC - NFPA 70) (USA). Installations in Canada shall comply with the relevant requirements of the Canadian Electrical Code (CEC Part I) (Canada). B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 6: Product Description

    (lightning strokes) or switching operations in the supply network. Further causes can be inductive or capacitive couplings from other electrical systems. Voltage peaks (transients) must be expected espe- cially when long power supply and signal cables are used. B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 7: Packaging, Transport And Storage

    3 Product description Such voltage surges can cause damage to sensors and controllers. The VEGA overvoltage arrester reduces voltage surges on the supply or signal cables to a safe level. They are designed for mounting on carrier rail according to EN 50 022/EN 50 035 in the switching cabinet or in a metal or plastic housing close to the sensor.
  • Page 8: Mounting Instructions

    Fig. 2: Mounting on carrier rail according to EN 50 022 (DIN rail) 35 x 7.5 mm Carrier rail Fig. 3: Mounting on carrier rail according to EN 50 035 (C-rail) 35 x 7.5 mm Carrier rail Installation procedure Proceed as follows: 1. Loosen fixing screw B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 9: Mounting In Housing

    The overvoltage arrester is optionally available in a plastic or alu- minium housing. Make sure when mounting that the cable glands point downward. Thus avoids water ingress. Fig. 5: Mounting in Aluminium housing Overvoltage protection Pressure compensation Ground terminal B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 10 This ground terminal must be connected (low impedance) with the potential equalization line (PA). The wire cross-section must be at least 2.5 mm , the cable must be as short as possible. B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 11: Connecting To Power Supply

    6. Tighten the compression nuts of the cable entry glands. The seal ring must completely encircle the cable 7. Tighten screws of the housing cover The electrical connection is finished. B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 12: Wiring Plan

    Wiring plan - Sensor protection A1+ A2- IP 20 E1+ E2- Fig. 8: Wiring plan B62-30W - Sensor protection (non-Ex applications) Sensor Overvoltage arrester for sensor Profibus PA System Potential equalisation B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 13 Wiring plan - Protection for bus system A1+ A2- IP 20 E1+ E2- Fig. 9: Wiring plan B62-30W - Protection for bus system (non-Ex applications) Sensor Overvoltage arrester for bus system Profibus PA System Potential equalisation B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 14: Diagnostics And Servicing

    24 hour service hotline Should these measures not be successful, please call in urgent cases the VEGA service hotline under the phone no. +49 1805 858550. The hotline is also available outside normal working hours, seven days a week around the clock.
  • Page 15: Dismount

    If personal data is stored on the old device to be disposed of, delete it before disposal. If you have no way to dispose of the old instrument properly, please contact us concerning return and disposal. B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 16: Certificates And Approvals

    The environment management system is certified according to DIN EN ISO 14001. Help us to meet these requirements and observe the environmental instructions in the chapters "Packaging, transport and storage", "Dis- posal" of this instructions manual. B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 17: Supplement

    Storage and transport temperature -40 … +70 °C (-40 … +158 °F) Electrical protective measures Protection rating Ʋ unassembled IP20 Ʋ In Aluminium or plastic housing IP65 Reference temperature 25 °C (77 °F). B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 18: Dimensions B62-30W

    9 Supplement Dimensions B62-30W Overvoltage protection 52 mm 25 mm (2.05") (0.98") Fig. 10: Dimensions B62-30W B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 19 M 20 x 1,5 (1.85") 77 mm 160 mm (3.03") (6.30") 130 mm (5.12") 72 mm 116 mm (2.84") (4.57") M 20 x 1,5 Fig. 11: Dimensions B62-30W Plastic housing Aluminium housing B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 20: Industrial Property Rights

    Les lignes de produits VEGA sont globalement protégées par des droits de propriété intellec- tuelle. Pour plus d'informations, on pourra se référer au site www.vega.com. VEGA lineas de productos están protegidas por los derechos en el campo de la propiedad indus- trial. Para mayor información revise la pagina web www.vega.com.
  • Page 21 Notes B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 22 Notes B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 23 Notes B62-30W • For Profibus PA and Foundation Fieldbus circuits...
  • Page 24 Subject to change without prior notice © VEGA Grieshaber KG, Schiltach/Germany 2024 VEGA Grieshaber KG Am Hohenstein 113 Phone +49 7836 50-0 77761 Schiltach E-mail: info.de@vega.com...

Table of Contents